A unified analysis of FBP-based algorithms in helical cone-beam and circular cone- and fan-beam scans

被引:53
作者
Pan, XC [1 ]
Xia, D [1 ]
Zou, Y [1 ]
Yu, LF [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
D O I
10.1088/0031-9155/49/18/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A circular scanning trajectory is and will likely remain a popular choice of trajectory in computed tomography (CT) imaging because it is easy to implement and control. Filtered-backprojection (FBP)-based algorithms have been developed previously for approximate and exact reconstruction of the entire image or a region of interest within the image in circular cone-beam and fan-beam cases. Recently, we have developed a 3D FBP-based algorithm for image reconstruction on PI-line segments in a helical cone-beam scan. In this work, we demonstrated that the 3D FBP-based algorithm indeed provided a rather general formulation for image reconstruction from divergent projections (such as cone-beam and fan-beam projections). On the basis of this formulation we derived new approximate or exact algorithms for image reconstruction in circular cone-beam or fan-beam scans, which can be interpreted as special cases of the helical scan. Existing algorithms corresponding to the derived algorithms were identified. We also performed a preliminary numerical study to verify our theoretical results in each of the cases. The results in the work can readily be generalized to other non-circular trajectories.
引用
收藏
页码:4349 / 4369
页数:21
相关论文
共 20 条
[1]   CT image reconstruction from fan-parallel data [J].
Besson, G .
MEDICAL PHYSICS, 1999, 26 (03) :415-426
[2]  
DANIELSSON PE, 1997, P 1997 INT M FULL 3, P141
[3]   A solution to the long-object problem in helical cone-beam tomography [J].
Defrise, M ;
Noo, F ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (03) :623-643
[4]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[5]   3D cone-beam CT reconstruction for circular trajectories [J].
Grass, M ;
Köhler, T ;
Proksa, R .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02) :329-347
[6]  
Hu H, 1996, SCANNING, V18, P572, DOI 10.1002/sca.4950180807
[7]  
Kak A.C. Slaney M., 1999, PRINCIPLES COMPUTERI
[8]  
KUDO H, 2002, IEEE MED IM C REC
[9]   Image reconstruction from fan-beam projections on less than a short scan [J].
Noo, F ;
Defrise, M ;
Clackdoyle, R ;
Kudo, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (14) :2525-2546
[10]   Optimal noise control in and fast reconstruction of fan-beam computed tomography image [J].
Pan, XC .
MEDICAL PHYSICS, 1999, 26 (05) :689-697