A multisyringe flow injection Winkler-based spectrophotometric analyzer for in-line monitoring of dissolved oxygen in seawater

被引:12
作者
Horstkotte, Burkhard [1 ]
Alonso, Juan Carlos [2 ]
Miro, Manuel [1 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, E-07122 Palma de Mallorca, Spain
[2] Inst Mediterrani Estudis Avancats IMEDEA, E-07190 Esporles, Spain
关键词
Multisyringe flow injection analysis; Dissolved oxygen; Winkler method; On-line monitoring; Seawater; ENVIRONMENTAL WATERS; SYSTEM;
D O I
10.1016/j.talanta.2009.09.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An integrated analyzer based on the multisyringe flow injection analysis approach is proposed for the automated determination of dissolved oxygen in seawater. The entire Winkler method including precipitation of manganese(II) hydroxide, fixation of dissolved oxygen, dissolution of the oxidized manganese hydroxide precipitate, and generation of iodine and tri-iodide ion are in-line effected within the flow network. Spectrophotometric quantification of iodine and tri-iodide at the isosbestic wavelength of 466 nm renders enhanced method reliability. The calibration function is linear up to 19 mg L-1 dissolved oxygen and an injection frequency of 17 per hour is achieved. The multisyringe system features a highly satisfying signal stability with repeatabilities of 2.2% RSD that make it suitable for continuous determination of dissolved oxygen in seawater. Compared to the manual starch-end-point titrimetric Winkler method and early reported automated systems, concentrations and consumption of reagents and sample are reduced up to hundredfold. The versatility of the multisyringe assembly was exploited in the implementation of an ancillary automatic batch-wise Winkler titrator using a single syringe of the module for accurate titration of the released iodine/tri-iodide with thiosulfate. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1341 / 1346
页数:6
相关论文
共 24 条
  • [1] A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes
    Albertús, F
    Horstkotte, B
    Cladera, A
    Cerdá, V
    [J]. ANALYST, 1999, 124 (09) : 1373 - 1381
  • [2] Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
  • [3] 2-9
  • [4] CERDA A, 2009, INTRO FLOW ANAL
  • [5] Flow techniques in water analysis
    Cerdà, V
    Estela, JM
    Forteza, R
    Cladera, A
    Becerra, E
    Altimira, P
    Sitjar, P
    [J]. TALANTA, 1999, 50 (04) : 695 - 705
  • [6] Clesceri L, 1998, STANDARD METHODS EXA
  • [7] Dickson A. G., 1996, WOCE OPERATIONS MANU
  • [8] AUTOMATIC POTENTIOMETRIC DETERMINATION OF DISSOLVED-OXYGEN
    GRANELI, W
    GRANELI, E
    [J]. MARINE BIOLOGY, 1991, 108 (02) : 341 - 348
  • [9] Grasshoff K., 1976, METHODS SEAWATER ANA, V2nd
  • [10] Horstkotte B., 2005, J. Flow Injection Anal, V22, P99