Estimated radiation risk of cancer from dental cone-beam computed tomography imaging in orthodontics patients

被引:31
作者
Yeh, Jih-Kuei [1 ]
Chen, Chia-Hui [2 ,3 ]
机构
[1] Kaohsiung Municipal United Hosp, Div Family Med, 976 Jhonghua 1st Rd, Kaohsiung 804, Taiwan
[2] Cent Taiwan Univ Sci & Technol, Dept Med Imaging & Radiol Sci, 666 Buzih Rd, Taichung 40601, Taiwan
[3] Natl Chiao Tung Univ, Coll Photon, 301,Gaofa 3rd Rd, Tainan 711, Taiwan
来源
BMC ORAL HEALTH | 2018年 / 18卷
关键词
Cone-beam computed tomography (CBCT); Organ doses; Monte Carlo simulation; PCXMC; Risk of exposure-induced death (REID); CT; DOSIMETRY; RADIOGRAPHS; DEVICES; IMAGES;
D O I
10.1186/s12903-018-0592-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Radiation dose evaluation is important to cone-beam computed tomography (CBCT) for routine orthodontic treatment planning, especially for a significant proportion of children in orthodontic patients. This study evaluated the patient radiation dose and estimated the radiation cancer risk on dental CBCT according to the calculations by the Monte Carlo simulation method. Methods: The dental CBCT scanner evaluated in this project was the i- CAT (R) (Imaging Sciences International Inc., PA, U.S.A.) device. Organ doses and effective doses were calculated by using personal computer-based Monte Carlo simulation (PCXMC 2.0 Rotation) software. The cancer risk resulting from the exposure to ionizing radiation was estimated by using the BEIR VII (Biologic Effects of Ionizing Radiation VII) report model, and the risk of exposure-induced death (REID) was assessed by PCXMC 2.0 Rotation software. Results: The largest contribution to the organ dose and effective dose at Zref 83 cm positioned in the dental CBCT x-ray beam centerline was from the salivary glands (738.29 mu Gy, 7.38 mu Sv). The different organ doses showed the maximum values at the different Zref locations, and the largest contribution to the organ dose and effective dose of all simulated positions was from the thyroid (928.77 mu Gy, 37.5 mu Sv). The REID values in the 10-year olds (22.6 x 10(-7), female; 19 x 10(-7), male) were approximately double than those in 30-year olds (10.4 x 10(-7), female; 8.88 x 10(-7), male) for all cancers. The highest change during age range from 10 to 30 was shown in breast cancer of females. Conclusions: Although individual cancer risk estimates as a function of gender and age are small, the concern about the risks from dental CBCT is related to the rapid increase in its use for orthodontic practice, especially in children patients.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The use of cone-beam computed tomography for orthodontic purposes
    Kuijpers-Jagtman, Anne Marie
    Kuijpers, Mette A. R.
    Schols, Jan G. J. H.
    Maal, Thomas J. J.
    Breuning, Karel H.
    van Vlijmen, Olivier J. C.
    SEMINARS IN ORTHODONTICS, 2013, 19 (03) : 196 - 203
  • [22] Accuracy of reconstructed images from cone-beam computed tomography scans
    Lamichane, Manish
    Anderson, Nina Kay
    Rigali, Paul H.
    Seldin, Edward B.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 156.e1 - 156.e6
  • [23] Optimising the parameters of cochlear implant imaging with cone-beam computed tomography
    Soederqvist, Samuel
    Sivonen, Ville
    Aarnisalo, Antti
    Karppi, Harri
    Sinkkonen, Saku T.
    Koivisto, Juha
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) : 462 - 470
  • [24] Relationship between the bone density estimated by cone-beam computed tomography and the primary stability of dental implants
    Isoda, Kei
    Ayukawa, Yasunori
    Tsukiyama, Yoshihiro
    Sogo, Motofumi
    Matsushita, Yasuyuki
    Koyano, Kiyoshi
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (07) : 832 - 836
  • [25] Comparison of Methods for Acceptance and Constancy Testing in Dental Cone-beam Computed Tomography
    Steiding, C.
    Kolditz, D.
    Kalender, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (04): : 283 - 290
  • [26] Cone beam computed tomography use in orthodontics
    Nervina, J. M.
    AUSTRALIAN DENTAL JOURNAL, 2012, 57 : 95 - 102
  • [27] DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY
    Andrade, Marcos E. A.
    Khoury, Helen J.
    Nascimento Neto, Joao B. S.
    Kramer, Richard
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 175 - 180
  • [28] Operator Radiation Exposure in Cone-Beam Computed Tomography Guidance
    Braak, S. J.
    Van, M. J. L. Strijen
    Meijer, E.
    Van, J. P. M. Heesewijk
    Mali, W. P. Th M.
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2016, 100 (01):
  • [29] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [30] Dental Cone Beam Computed Tomography in Children: Clinical Effectiveness and Cancer Risk due to Radiation Exposure
    De Felice, Francesca
    Di Carlo, Gabriele
    Saccucci, Matteo
    Tombolini, Vincenzo
    Polimeni, Antonella
    ONCOLOGY, 2019, 96 (04) : 173 - 178