A Time Resolution Study of a Continuous Crystal Detector for TOF PET

被引:2
|
作者
Szczesniak, T. [1 ]
Moszynski, M. [1 ]
Swiderski, L. [1 ]
Nassalski, A. [1 ]
Syntfeld-Kazuch, A. [1 ]
Ojala, P. [2 ]
Bohm, C. [2 ]
机构
[1] Soltan Inst Nucl Studies, PL-05400 Otwock, Poland
[2] Stockholm Univ, Dept Phys, AlbaNova Univ Ctr, SE-10691 Stockholm, Sweden
关键词
Fast PMTs; fast timing; LSO scintillator; time-of-Flight PET; OF-FLIGHT PET; FAST PHOTOMULTIPLIERS; LSO; PERFORMANCE; PROSPECTS;
D O I
10.1109/TNS.2009.2035619
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The majority of current Positron Emission Tomography (PET) systems are based on block-detectors consisting of many scintillating pixels read by a smaller number of photomultipliers (PMTs). An improvement of the time resolution, using a common light readout from a cluster of PMTs, was proposed by Kuhn et al., and tested by us earlier with LSO crystals. This, triggered an idea to design a new PET detector optimized for Time of Flight (TOF) systems, based on continuous crystals. In the present work, we report on optimization of timing with a 20 x 20 x 20 mm(3) LYSO crystal coupled to a 16-channel photomultiplier H8711-200MOD from Hamamatsu. First, measurements were performed of the transit time jitter, the number of photoelectrons and the time resolution using a small 10 x 10 x 5 mm(3) LSO crystal coupled to a H8711-200MOD PMT. Results were compared with data collected from fast timing photomultipliers like Photonis XP1020, XP3060, XP20D0 or Hamamatsu R9800. In the second part of the study, the time resolution measurements and the optimization of the system were made with a continuous LYSO crystal. The final results are discussed in terms of the measured photoelectron number and the requirements for the TOF-PET scanners.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [21] Development of a TOF Detector for Brain PET
    Choe, Hyeok-jun
    Choi, Yong
    Jung, Jin Ho
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [22] Sparse SiPM Pixel Arrangement for a TOF-PET Detector Design that Achieves 100 ps Coincidence Time Resolution
    Cates, J. W.
    Levin, C. S.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (07) : 665 - 672
  • [23] Improving TOF Mass Resolution by Reducing Ion Detector Time Jitter
    Ritzau, Steve
    Holmes, Paula
    Mitchell, Paul
    Laprade, Bruce
    LC GC NORTH AMERICA, 2010, : 68 - 68
  • [24] Analysis of the factors that influence the time resolution of TOF in BES III detector
    Liu, JG
    An, Q
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (11): : 1170 - 1175
  • [25] Development of high time resolution multigap RPCS for the ToF detector of ALICE
    Williams, MCS
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 563 - 568
  • [26] Study of "A method to enhance coincidence time resolution with applications for medical imaging systems (TOF/PET)"
    Bikit, I.
    Mrdja, D.
    Bikit, K.
    Slivka, J.
    Forkapic, S.
    RADIATION MEASUREMENTS, 2015, 72 : 95 - 99
  • [27] Advantages of Improved Time Resolution for TOF PET at Very Low Statistics
    Westerwoudt, Victor
    Conti, Maurizio
    Eriksson, Lars
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 126 - 133
  • [28] Optimized TOF-PET detector using scintillation crystal array for brain imaging
    Leem, Hyuntae
    Choi, Yong
    Jung, Jiwoong
    Park, Kuntai
    Kim, Yeonkyeong
    Jung, Jin Ho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (07) : 2592 - 2598
  • [29] Characterization of stacked-crystal PET detector designs for measurement of both TOF and DOI
    Schmall, Jeffrey P.
    Surti, Suleman
    Karp, Joel S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (09): : 3549 - 3565
  • [30] Studies on the Cherenkov Effect for Improved Time Resolution of TOF-PET
    Brunner, S. E.
    Gruber, L.
    Marton, J.
    Suzuki, K.
    Hirtl, A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (01) : 443 - 447