IMPROVED ULTRASOUND MICROVESSEL IMAGING USING DECONVOLUTION WITH TOTAL VARIATION REGULARIZATION

被引:10
作者
Lok, U-Wai [1 ]
Trzasko, Joshua D. [1 ]
Huang, Chengwu [1 ]
Tang, Shanshan [1 ]
Gong, Ping [1 ]
Kim, Yohan [2 ]
Lucien, Fabrice [2 ]
Lowerison, Matthew R. [1 ,3 ,4 ]
Song, Pengfei [1 ,3 ,4 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clin, Dept Radiol, Coll Med & Sci, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Urol, Coll Med & Sci, Rochester, MN 55905 USA
[3] Univ Illinois, Beckman Inst, Urbana, IL USA
[4] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA
基金
美国国家卫生研究院;
关键词
Deconvolution; Microvessel imaging; Power Doppler imaging;
D O I
10.1016/j.ultrasmedbio.2020.12.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Singular value decomposition-based clutter filters can robustly reject tissue clutter, allowing for detection of slow blood flow in imaging microvasculature. However, to identify microvessels, high ultrasound frequency must be used to increase the spatial resolution at the expense of shorter depth of penetration. Deconvolution using Tikhonov regularization is an imaging processing method widely used to improve spatial resolution. The ringing artifact of Tikhonov regularization, though, can produce image artifacts such as non-existent microvessels, which degrade image quality. Therefore, a deconvolution method using total variation is proposed in this study to improve spatial resolution and mitigate the ringing artifact. Performance of the proposed method was evaluated using chicken embryo brain, ex ovo chicken embryo chorioallantoic membrane and tumor data. Results revealed that the reconstructed power Doppler (PD) images are substantially improved in spatial resolution compared with original PD images: the full width half-maximum (FWHM) of the cross-sectional profile of a microvessel was improved from 132 to 83 mm. Two neighboring microvessels that were 154 mm apart were better separated using the proposed method than conventional PD imaging. Additionally, 223 FWHMs measured from the cross-sectional profiles of 223 vessels were used to determine the improvement in FWHM with the proposed method statistically. The mean ? standard deviation of the FWHM without and with the proposed method was 233.19 ? 85.08 and 172.31 ? 75.11 mm, respectively; the maximum FWHM without and with the proposed method was 693.01 and 668.69 mm; and the minimum FWHM without and with the proposed method was 73.92 and 45.74 mm. There were statistically significant differences between FWHMs with and without the proposed method according to the rank-sum test, p < 0.0001. The contrast-to-noise ratio improved from 1.06 to 4.03 dB with use of the proposed method. We also compared the proposed method with Tikhonov regularization using ex ovo chicken embryo chorioallantoic membrane data. We found that the proposed method outperformed Tikhonov regularization as false microvessels appeared using the Tikhonov regularization but not with the proposed method. These results indicate that the proposed method is capable of providing more robust PD images with higher spatial resolution and higher contrast-to-noise ratio. (E-mail: Chen.Shigao@mayo.edu) ? 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1089 / 1098
页数:10
相关论文
共 19 条
[11]   The Singular Value Filter: A General Filter Design Strategy for PCA-Based Signal Separation in Medical Ultrasound Imaging [J].
Mauldin, F. William, Jr. ;
Lin, Dan ;
Hossack, John A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (11) :1951-1964
[12]   Ultrasonic imaging using a computed point spread function [J].
Rangarajan, Ramsharan ;
Krishnamurthy, C. V. ;
Balasubramaniam, Krishnan .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (02) :451-464
[13]   The Generalized Contrast-to-Noise Ratio: A Formal Definition for Lesion Detectability [J].
Rodriguez-Molares, Alfonso ;
Rindal, Ole Marius Hoel ;
D'hooge, Jan ;
Masoy, Svein-Erik ;
Austeng, Andreas ;
Bell, Muyinatu A. Lediju ;
Torp, Hans .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (04) :745-759
[14]   Sensitivity to point-spread function parameters in medical ultrasound image deconvolution [J].
Shin, Ho-Chul ;
Prager, Richard ;
Ng, James ;
Gomersall, Henry ;
Kingsbury, Nick ;
Treece, Graham ;
Gee, Andrew .
ULTRASONICS, 2009, 49 (03) :344-357
[15]   Noise Equalization for Ultrafast Plane Wave Microvessel Imaging [J].
Song, Pengfei ;
Manduca, Armando ;
Trzasko, Joshua D. ;
Chen, Shigao .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (11) :1776-1781
[16]   Accelerated Singular Value-Based Ultrasound Blood Flow Clutter Filtering With Randomized Singular Value Decomposition and Randomized Spatial Downsampling [J].
Song, Pengfei ;
Trzasko, Joshua D. ;
Manduca, Armando ;
Qiang, Bo ;
Kadirvel, Ramanathan ;
Kallmes, David F. ;
Chen, Shigao .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (04) :706-716
[17]   Ultrasound Small Vessel Imaging With Block-Wise Adaptive Local Clutter Filtering [J].
Song, Pengfei ;
Manduca, Armando ;
Trzasko, Joshua D. ;
Chen, Shigao .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) :251-262
[18]  
Starck JL, 2002, IEEE T IMAGE PROCESS, V11, P670, DOI [10.1109/TIP.2002.1014998, 10.1117/12.408568]
[19]   Robust Image Restoration for Motion Blur of Image Sensors [J].
Yang, Fasheng ;
Huang, Yongmei ;
Luo, Yihan ;
Li, Lixing ;
Li, Hongwei .
SENSORS, 2016, 16 (06)