IMPROVED ULTRASOUND MICROVESSEL IMAGING USING DECONVOLUTION WITH TOTAL VARIATION REGULARIZATION

被引:10
作者
Lok, U-Wai [1 ]
Trzasko, Joshua D. [1 ]
Huang, Chengwu [1 ]
Tang, Shanshan [1 ]
Gong, Ping [1 ]
Kim, Yohan [2 ]
Lucien, Fabrice [2 ]
Lowerison, Matthew R. [1 ,3 ,4 ]
Song, Pengfei [1 ,3 ,4 ]
Chen, Shigao [1 ]
机构
[1] Mayo Clin, Dept Radiol, Coll Med & Sci, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Urol, Coll Med & Sci, Rochester, MN 55905 USA
[3] Univ Illinois, Beckman Inst, Urbana, IL USA
[4] Univ Illinois, Dept Elect & Comp Engn, Urbana, IL USA
基金
美国国家卫生研究院;
关键词
Deconvolution; Microvessel imaging; Power Doppler imaging;
D O I
10.1016/j.ultrasmedbio.2020.12.025
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Singular value decomposition-based clutter filters can robustly reject tissue clutter, allowing for detection of slow blood flow in imaging microvasculature. However, to identify microvessels, high ultrasound frequency must be used to increase the spatial resolution at the expense of shorter depth of penetration. Deconvolution using Tikhonov regularization is an imaging processing method widely used to improve spatial resolution. The ringing artifact of Tikhonov regularization, though, can produce image artifacts such as non-existent microvessels, which degrade image quality. Therefore, a deconvolution method using total variation is proposed in this study to improve spatial resolution and mitigate the ringing artifact. Performance of the proposed method was evaluated using chicken embryo brain, ex ovo chicken embryo chorioallantoic membrane and tumor data. Results revealed that the reconstructed power Doppler (PD) images are substantially improved in spatial resolution compared with original PD images: the full width half-maximum (FWHM) of the cross-sectional profile of a microvessel was improved from 132 to 83 mm. Two neighboring microvessels that were 154 mm apart were better separated using the proposed method than conventional PD imaging. Additionally, 223 FWHMs measured from the cross-sectional profiles of 223 vessels were used to determine the improvement in FWHM with the proposed method statistically. The mean ? standard deviation of the FWHM without and with the proposed method was 233.19 ? 85.08 and 172.31 ? 75.11 mm, respectively; the maximum FWHM without and with the proposed method was 693.01 and 668.69 mm; and the minimum FWHM without and with the proposed method was 73.92 and 45.74 mm. There were statistically significant differences between FWHMs with and without the proposed method according to the rank-sum test, p < 0.0001. The contrast-to-noise ratio improved from 1.06 to 4.03 dB with use of the proposed method. We also compared the proposed method with Tikhonov regularization using ex ovo chicken embryo chorioallantoic membrane data. We found that the proposed method outperformed Tikhonov regularization as false microvessels appeared using the Tikhonov regularization but not with the proposed method. These results indicate that the proposed method is capable of providing more robust PD images with higher spatial resolution and higher contrast-to-noise ratio. (E-mail: Chen.Shigao@mayo.edu) ? 2021 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1089 / 1098
页数:10
相关论文
共 19 条
[1]   An efficient wavelet and curvelet-based PET image denoising technique [J].
Bal, Abhishek ;
Banerjee, Minakshi ;
Sharma, Punit ;
Maitra, Mausumi .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (12) :2567-2598
[2]   A First-Order Primal-Dual Algorithm for Convex Problems with Applications to Imaging [J].
Chambolle, Antonin ;
Pock, Thomas .
JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2011, 40 (01) :120-145
[3]   Spatiotemporal Clutter Filtering of Ultrafast Ultrasound Data Highly Increases Doppler and fUltrasound Sensitivity [J].
Demene, Charlie ;
Deffieux, Thomas ;
Pernot, Mathieu ;
Osmanski, Bruno-Felix ;
Biran, Valerie ;
Gennisson, Jean-Luc ;
Sieu, Lim-Anna ;
Bergel, Antoine ;
Franqui, Stephanie ;
Correas, Jean-Michel ;
Cohen, Ivan ;
Baud, Olivier ;
Tanter, Mickael .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (11) :2271-2285
[4]   Richardson-Lucy algorithm with total variation regularization for 3D confocal microscope deconvolution [J].
Dey, N ;
Blanc-Feraud, L ;
Zimmer, C ;
Roux, P ;
Kam, Z ;
Olivo-Marin, JC ;
Zerubia, J .
MICROSCOPY RESEARCH AND TECHNIQUE, 2006, 69 (04) :260-266
[5]  
Grabner M, COMP VIS WORKSH 2007
[6]   Debiasing-Based Noise Suppression for Ultrafast Ultrasound Microvessel Imaging [J].
Huang, Chengwu ;
Song, Pengfei ;
Gong, Ping ;
Trzasko, Joshua D. ;
Manduca, Armando ;
Chen, Shigao .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (08) :1281-1291
[7]   Noninvasive Contrast-Free 3D Evaluation of Tumor Angiogenesis with Ultrasensitive Ultrasound Microvessel Imaging [J].
Huang, Chengwu ;
Lowerison, Matthew R. ;
Lucien, Fabrice ;
Gong, Ping ;
Wang, Diping ;
Song, Pengfei ;
Chen, Shigao .
SCIENTIFIC REPORTS, 2019, 9 (1)
[8]   DECONVOLUTION OF IN-VIVO ULTRASOUND B-MODE IMAGES [J].
JENSEN, JA ;
MATHORNE, J ;
GRAVESEN, T ;
STAGE, B .
ULTRASONIC IMAGING, 1993, 15 (02) :122-133
[9]   A new method for deblurring and denoising of medical images using Complex Wavelet Transform [J].
Khare, Ashish ;
Tiwary, Uma Shanker .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :1897-1900
[10]   Real time SVD-based clutter filtering using randomized singular value decomposition and spatial downsampling for micro-vessel imaging on a Verasonics ultrasound system [J].
Lok, U-Wai ;
Song, Pengfei ;
Trzasko, Joshua D. ;
Daigle, Ron ;
Borisch, Eric A. ;
Huang, Chengwu ;
Gong, Ping ;
Tang, Shanshan ;
Ling, Wenwu ;
Chen, Shigao .
ULTRASONICS, 2020, 107