Non-Invasive Detection of Mechanical Alternans Utilizing Photoplethysmography

被引:7
作者
Besleaga, Tudor [1 ]
Badiani, Sveeta [2 ]
Lloyd, Guy [2 ]
Toschi, Nicola [3 ,4 ,5 ]
Canichella, Antonio [3 ]
Demosthenous, Andreas [6 ]
Lambiase, Pier David [7 ]
Orini, Michele [7 ,8 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, London WC1E 6BT, England
[2] St Bartholomews Hosp, Barts Heart Ctr, Echocardiog Lab, London EC1A 7BE, England
[3] Univ Roma Tor Vergata, Dept Biomed & Prevent, Med Phys Sect, I-00133 Rome, Italy
[4] Massachusetts Gen Hosp, AA Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[5] Harvard Med Sch, Charlestown, MA 02129 USA
[6] UCL, Dept Elect & Elect Engn, London WC1E 7JE, England
[7] St Bartholomews Hosp, Barts Heart Ctr, Electrophysiol Dept, London EC1A 7BE, England
[8] UCL, Dept Mech Engn, London WC1E 6BT, England
关键词
Blood pressure (BP); cardiac alternans; hemodynamic instabilities; mechanical alternans (MA); photoplethysmography (PPG); PULSE-RATE VARIABILITY; CARDIAC ALTERNANS; PRESSURE; WAVE;
D O I
10.1109/JBHI.2018.2882550
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background and Significance: Mechanical alternans (MA) is a biomarker associated with mortality and life-threatening arrhythmias in heart failure patients. Despite showing prognostic value, its use is limited by the requirement of measuring the continuous blood pressure (BP), which is costly and impractical. Objective: To develop and test, for the first time, non-invasive MA surrogates based on photoplethysmography (PPG). Methods: Continuous BP and PPG were recorded during clinical procedures and tests in 35 patients. MA was induced either by ventricular pacing (Group A, N = 19) or exercise (Group B, N = 16). MA was categorized as sustained or intermittent if MA episodes were observed in at least 20 or between 12 and 20 consecutive beats, respectively. Eight features characterizing the pulse morphology were derived from the PPG, and MA surrogates were evaluated. Results: Sustained alternans was observed in 9 patients (47%) from Group A, whereas intermittent alternans was observed in 13 patients (68%) from Group A and in 10 patients (63%) from Group B. The PPG-based MA surrogate showing the highest accuracy, V-M, was based on the maximum of the first derivative of the PPG pulse. It detected both sustained and intermittent MA with 100% sensitivity and 100% specificity in Group A and intermittent MA with 100% sensitivity and 83% specificity in Group B. Furthermore, the magnitudes of MA and its PPG-based surrogate were linearly correlated (R-2 = 0.83, p < 0.001). Conclusion: MA can be accurately identified non-invasively through PPG analysis. This may have important clinical implications for risk stratification and remote monitoring.
引用
收藏
页码:2409 / 2416
页数:8
相关论文
共 40 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger [J].
Bogert, LWJ ;
van Lieshout, JJ .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) :437-446
[3]   Pulse Rate and Transit Time Analysis to Predict Hypotension Events After Spinal Anesthesia During Programmed Cesarean Labor [J].
Bolea, Juan ;
Lazaro, Jesus ;
Gil, Eduardo ;
Rovira, Eva ;
Remartinez, Jose M. ;
Laguna, Pablo ;
Pueyo, Esther ;
Navarro, Augusto ;
Bailon, Raquel .
ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (09) :2253-2263
[5]  
Child N., 2017, COMPUT CARDIOL, V44, P2
[6]   MECHANISMS OF PULSUS ALTERNANS [J].
COHN, KE ;
SANDLER, H ;
HANCOCK, EW .
CIRCULATION, 1967, 36 (03) :372-+
[7]   Detection of atrial fibrillation episodes using a wristband device [J].
Corino, Valentina D. A. ;
Laureanti, Rita ;
Ferranti, Lorenzo ;
Scarpini, Giorgio ;
Lombardi, Federico ;
Mainardi, Luca T. .
PHYSIOLOGICAL MEASUREMENT, 2017, 38 (05) :787-799
[8]   A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features [J].
Dao, Duy ;
Salehizadeh, S. M. A. ;
Noh, Yeonsik ;
Chong, Jo Woon ;
Cho, Chae Ho ;
McManus, Dave ;
Darling, Chad E. ;
Mendelson, Yitzhak ;
Chon, Ki H. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2017, 21 (05) :1242-1253
[9]   Blastocystis subtyping and its association with intestinal parasites in children from different geographical regions of Colombia [J].
David Ramirez, Juan ;
Florez, Carolina ;
Olivera, Mario ;
Consuelo Bernal, Maria ;
Cesar Giraldo, Julio .
PLOS ONE, 2017, 12 (02)
[10]   Evaluation of cardiac modulation in children in response to apnea/hypopnea using the Phone Oximeter™ [J].
Dehkordi, Parastoo ;
Garde, Ainara ;
Karlen, Walter ;
Petersen, Christian L. ;
Wensley, David ;
Dumont, Guy A. ;
Ansermino, J. Mark .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (02) :187-202