Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance

被引:26
|
作者
Houriez-Gombaud-Saintonge, Sophia [1 ,2 ,3 ]
Mousseaux, Elie [4 ]
Bargiotas, Ioannis [5 ]
De Cesare, Alain [1 ,3 ]
Dietenbeck, Thomas [1 ,3 ]
Bouaou, Kevin [1 ,3 ]
Redheuil, Alban [1 ,3 ]
Soulat, Gilles [4 ]
Giron, Alain [1 ]
Gencer, Umit [4 ]
Craiem, Damian [6 ]
Messas, Emmanuel [4 ]
Bollache, Emilie [1 ,3 ]
Chenoune, Yasmina [2 ]
Kachenoura, Nadjia [1 ,3 ]
机构
[1] Sorbonne Univ, INSERM, CNRS, LIB, F-75006 Paris, France
[2] ESME Sudria Res Lab, Paris, France
[3] ICAN, Paris, France
[4] Hop Europeen Georges Pompidou, Paris, France
[5] Univ Paris Saclay, CMLA, ENS Cachan, CNRS, F-94235 Cachan, France
[6] Univ Favaloro, CONICET, IMeTTyB, Buenos Aires, DF, Argentina
关键词
Pulse wave velocity; 4D flow CMR; Aortic stiffness; Aging; ARTERIAL STIFFNESS; TRANSIT-TIME; MRI; PRESSURE; AGE; REPRODUCIBILITY; REFLECTION; VALIDATION; MORTALITY; 2D;
D O I
10.1186/s12968-019-0584-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. Methods We studied 47 healthy subjects (49.5 +/- 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. Results 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). Conclusions Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw).
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Sophia Houriez--Gombaud-Saintonge
    Elie Mousseaux
    Ioannis Bargiotas
    Alain De Cesare
    Thomas Dietenbeck
    Kevin Bouaou
    Alban Redheuil
    Gilles Soulat
    Alain Giron
    Umit Gencer
    Damian Craiem
    Emmanuel Messas
    Emilie Bollache
    Yasmina Chenoune
    Nadjia Kachenoura
    Journal of Cardiovascular Magnetic Resonance, 21
  • [2] The Assessment of Aortic Pulse Wave Velocity Using 4D Flow Magnetic Resonance Imaging: Methods Comparison
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Gencer, Umit
    Craiem, Damian
    Chenoune, Yasmina
    Kachenoura, Nadjia
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [3] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Ruesink, Timothy
    Medero, Rafael
    Rutkowski, David
    Roldan-Alzate, Alejandro
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 674 - 687
  • [4] Estimation of Global Aortic Pulse Wave Velocity by Flow-Sensitive 4D MRI
    Markl, Michael
    Wallis, Wolf
    Brendecke, Stefanie
    Simon, Jan
    Frydrychowicz, Alex
    Harloff, Andreas
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (06) : 1575 - 1582
  • [5] Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI
    Park, Sungho
    Kwon, Minseong
    Nam, Hyojin
    Huh, Hyungkyu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [6] Aortic Pulse Wave Velocity Evaluated by 4D Flow MRI Across the Adult Lifespan
    Jarvis, Kelly
    Scott, Michael B.
    Soulat, Gilles
    Elbaz, Mohammed S. M.
    Barker, Alex J.
    Carr, James C.
    Markl, Michael
    Ragin, Ann
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 464 - 473
  • [7] Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements
    Hametner, Bernhard
    Wassertheurer, Siegfried
    Kropf, Johannes
    Mayer, Christopher
    Eber, Bernd
    Weber, Thomas
    BLOOD PRESSURE MONITORING, 2013, 18 (03) : 173 - 176
  • [8] In Vitro Validation of 4D Flow MRI for Local Pulse Wave Velocity Estimation
    Timothy Ruesink
    Rafael Medero
    David Rutkowski
    Alejandro Roldán-Alzate
    Cardiovascular Engineering and Technology, 2018, 9 : 674 - 687
  • [9] Comparison of an Oscillometric Method with Cardiac Magnetic Resonance for the Analysis of Aortic Pulse Wave Velocity
    Feistritzer, Hans-Josef
    Reinstadler, Sebastian J.
    Klug, Gert
    Kremser, Christian
    Seidner, Benjamin
    Esterhammer, Regina
    Schocke, Michael F.
    Franz, Wolfgang-Michael
    Metzler, Bernhard
    PLOS ONE, 2015, 10 (01):
  • [10] A magnetic resonance perspective of the pulse wave transit time by the Arteriograph device and potential for improving aortic length estimation for central pulse wave velocity
    Rezai, Mohammad-Reza
    Cowan, Brett R.
    Sherratt, Neal
    Finn, Joseph D.
    Wu, Frederick C. W.
    Cruickshank, J. Kennedy
    BLOOD PRESSURE MONITORING, 2013, 18 (02) : 111 - 118