Spotlight on the Corneal Back Surface Astigmatism: A Review

被引:9
|
作者
Patel, Sudi [1 ]
Tutchenko, Larysa [2 ]
机构
[1] Univ Rijeka, Svjetlost Special Eye Hosp, Sch Med, Zagreb, Croatia
[2] Kyiv City Clin Ophthalmol Hosp, Eye Microsurg Ctr, Kiev, Ukraine
来源
CLINICAL OPHTHALMOLOGY | 2021年 / 15卷
关键词
cornea; back surface; astigmatism; radius; thickness; refractive index; SURGICALLY INDUCED ASTIGMATISM; TORIC INTRAOCULAR-LENS; HONG-KONG CHINESE; POSTERIOR SURFACE; ANTERIOR SEGMENT; CATARACT-SURGERY; NORMAL EYES; POWER; TOPOGRAPHY; CURVATURE;
D O I
10.2147/OPTH.S284616
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Recent evidence indicates that the corneal back surface astigmatism (CBSA) contributes to the refractive state of the eye in cataract surgery, especially with the implantation of toric intraocular lenses. But this has been met with some scepticism. A review of key studies performed over the past three decades shows that the mean CBSA power ranges from 0.18(+/- 0.16)D to 1.04(+/- 0.20)D. The clinical assessment of CBSA is problematic. There is poor agreement between the current automated systems for assessment of CBSA and it is assumed that these systems directly measure the CBSA. But CBSA cannot be measured directly in vivo. A historical review of methods used to quantify the curvature of the posterior corneal surface reveals that CBSA estimated by current systems is based on values for corneal front surface astigmatism, corneal refractive index, central corneal thickness, corneal thickness at peripheral locations and the exact distance between the corneal apex and each one of these peripheral locations. Doubts and errors in these values, coupled with the precise details of the algorithm incorporated to estimate CBSA, are the likely sources of the lack of agreement between current systems. These systematic errors cloud the assessment of CBSA. Mean CBSA may be low, but it varies from case to case. There is a clear need for a realistic, practical procedure for clinicians to independently calibrate systems for estimating CBSA. This would help to reduce uncertainty and the discrepancies between instruments designed to measure the same parameter.
引用
收藏
页码:3157 / 3164
页数:8
相关论文
共 50 条
  • [1] The Impact of Changes in Corneal Back Surface Astigmatism on the Residual Astigmatic Refractive Error following Routine Uncomplicated Phacoemulsification
    Tutchenko, Larysa
    Patel, Sudi
    Voytsekhivskyy, Oleksiy
    Skovron, Mykhailo
    Horak, Olha
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [2] Posterior corneal astigmatism: a review article
    Mohammadi, Seyed-Farzad
    Khorrami-Nejad, Masoud
    Hamidirad, Moein
    CLINICAL OPTOMETRY, 2019, 11 : 85 - 96
  • [3] Effects of posterior corneal astigmatism on the accuracy of AcrySof toric intraocular lens astigmatism correction
    Zhang, Bin
    Ma, Jing-Xu
    Liu, Dan-Yan
    Guo, Cong-Rong
    Du, Ying-Hua
    Guo, Xiu-Jin
    Cui, Yue-Xian
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (09) : 1276 - 1282
  • [4] POSTERIOR CORNEAL SURFACE TORICITY AND TOTAL CORNEAL ASTIGMATISM
    DUNNE, MCM
    ROYSTON, JM
    BARNES, DA
    OPTOMETRY AND VISION SCIENCE, 1991, 68 (09) : 708 - 710
  • [5] Influence of Posterior Corneal Astigmatism on Total Corneal Astigmatism in Eyes With Keratoconus
    Savini, Giacomo
    Naeser, Kristian
    Schiano-Lomoriello, Domenico
    Mularoni, Alessandro
    CORNEA, 2016, 35 (11) : 1427 - 1433
  • [6] Effects of pterygium surgery on front and back corneal astigmatism
    Kheirkhah, Ahmad
    Safi, Hamid
    Molaei, Saber
    Nazari, Rahman
    Behrouz, Mahmoud Jabbarvand
    Raju, Vadrevu K.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2012, 47 (05): : 423 - 428
  • [7] Evaluation of statistical correction strategies for corneal back surface astigmatism with toric lenses: a vector analysis
    Langenbucher, Achim
    Hoffmann, Peter
    Cayless, Alan
    Wendelstein, Jascha
    Szentmary, Nora
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04) : 385 - 393
  • [8] Surgical approaches to correct corneal astigmatism at time of cataract surgery: a mini-review
    Yin, Xiao-Lei
    Ji, Zhi-Yang
    Li, Xiu-Xin
    Liang, Xue-Mei
    Ji, Shu-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (07) : 1370 - 1374
  • [9] The effect of posterior corneal flat meridian and astigmatism amount on the total corneal astigmatism estimated from anterior corneal measurements
    Eom, Youngsub
    Kang, Su-Yeon
    Kim, Hyo Myung
    Song, Jong Suk
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (11) : 1769 - 1777
  • [10] Toric Intraocular Lens Calculation Considering Anterior Surgically Induced Astigmatism and Posterior Corneal Astigmatism
    Fernandez, Joaquin
    Rodriguez-Vallejo, Manuel
    Rocha-de-Lossada, Carlos
    Hueso, Elisa
    Pinero, David
    CURRENT EYE RESEARCH, 2022, 47 (01) : 25 - 31