Purpose: The primary stability of dental implants is one of the most crucial factors for providing long-term success of osseointegration. Vertical deficiencies, such as those due to maxillary sinus pneumatization, may cause a severe vertical limitation to residual bone height. This study aimed to examine the primary stabilization of implants without apical contacts. Materials and Methods: Eighty bone-level implants (4.1-mm diameter/10-mm length) were placed into polyurethane test blocks without apical contacts. According to coronal bone-to-implant contact, groups were set as 4,6, 8, and 10 mm, respectively. Resonance frequency analysis (RFA) using a SmartPeg was performed separately toward the transversal and horizontal axes by two independent researchers. Data were statistically compared for interobserver and among groups. Results: Interobserver reliability varied from moderate to excellent (intraclass correlation coefficient [ICC]: 0.629 to 0.985). There were no significant differences among the 6 mm, 8 mm, and 10 mm groups, although the 4 mm group showed the significantly lowest stability (P < .001). Transversal and longitudinal measurements of the same groups did not show a parallel correlation statistically. Conclusion: RFA values may be affected by the finger torque in tightening of the SmartPeg among different researchers. Fully placed implants did not significantly show the highest stability among various apically contactless groups. Consequently, RFA should not be used alone to evaluate primary stability for implants without an apical contact.
机构:Sao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil
Barella Salatti, Debora
Antonio Pelegrine, Andre
论文数: 0引用数: 0
h-index: 0
机构:
Sao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, BrazilSao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil
Antonio Pelegrine, Andre
Gehrke, Sergio
论文数: 0引用数: 0
h-index: 0
机构:
Catholic Univ Murcia, Biotechnol Dept, Murcia, Spain
Biotecnos Res Ctr, Dept Res, Montevideo, UruguaySao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil
Gehrke, Sergio
Teixeira, Marcelo Lucchesi
论文数: 0引用数: 0
h-index: 0
机构:
Sao Leopoldo Mand Inst & Res Ctr, Dept Prosthodont, Campinas, SP, BrazilSao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil
Teixeira, Marcelo Lucchesi
Moshaverinia, Alireza
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif Los Angeles, Sch Dent, Weintraub Ctr Reconstruct Biotechnol, Div Adv Prosthodont, Los Angeles, CA 90024 USASao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil
Moshaverinia, Alireza
Moy, Peter Karyen
论文数: 0引用数: 0
h-index: 0
机构:
Univ Calif Los Angeles, Sch Dent, Dent Implant Ctr, Dept Oral & Maxillofacial Surg, Los Angeles, CA 90024 USASao Leopoldo Mand Inst & Res Ctr, Dept Implant Dent, Campinas, SP, Brazil