Is Resonance Frequency Analysis a Reliable Evaluation for Primary Stability of Implants Without Apical Contact?

被引:0
|
作者
Ozyurt, Anil [1 ,3 ]
Bilmenoglu, Caglar [2 ]
机构
[1] Dokuz Eylul Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Izmir, Turkey
[2] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey
[3] Trakya Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Edirne, Turkey
关键词
apically contactless; dental implant; primary stability; resonance frequency analysis; SINUS FLOOR ELEVATION; ATROPHIC POSTERIOR MAXILLA; SURGICAL TECHNIQUE; INSERTION TORQUE; COLLAR DESIGN; BONE; PLACEMENT; SURGERY; SURFACE; SHAPE;
D O I
10.11607/jomi.9480
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The primary stability of dental implants is one of the most crucial factors for providing long-term success of osseointegration. Vertical deficiencies, such as those due to maxillary sinus pneumatization, may cause a severe vertical limitation to residual bone height. This study aimed to examine the primary stabilization of implants without apical contacts. Materials and Methods: Eighty bone-level implants (4.1-mm diameter/10-mm length) were placed into polyurethane test blocks without apical contacts. According to coronal bone-to-implant contact, groups were set as 4,6, 8, and 10 mm, respectively. Resonance frequency analysis (RFA) using a SmartPeg was performed separately toward the transversal and horizontal axes by two independent researchers. Data were statistically compared for interobserver and among groups. Results: Interobserver reliability varied from moderate to excellent (intraclass correlation coefficient [ICC]: 0.629 to 0.985). There were no significant differences among the 6 mm, 8 mm, and 10 mm groups, although the 4 mm group showed the significantly lowest stability (P < .001). Transversal and longitudinal measurements of the same groups did not show a parallel correlation statistically. Conclusion: RFA values may be affected by the finger torque in tightening of the SmartPeg among different researchers. Fully placed implants did not significantly show the highest stability among various apically contactless groups. Consequently, RFA should not be used alone to evaluate primary stability for implants without an apical contact.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 50 条
  • [31] The evaluation of implant stability measured by resonance frequency analysis in different bone types
    Sargolzaie, Naser
    Samizade, Sarah
    Arab, Hamidreza
    Ghanbari, Habibollah
    Khodadadifard, Leila
    Khajavi, Amin
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2019, 45 (01) : 29 - 33
  • [32] Evaluation of primary stability of implants in bovine bone defects models
    Kim, Minji
    Lee, Jae-Hyun
    Kim, Hyo-seon
    Lee, Su Young
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [33] Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants
    Kahraman, S.
    Bal, B. T.
    Asar, N. V.
    Turkyilmaz, I.
    Tozum, T. F.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (10) : 755 - 761
  • [34] In vitro comparative analysis of two resonance frequency measurement devices: Osstell implant stability coefficient and Penguin resonance frequency analysis
    Herrero-Climent, Mariano
    Falcao, Artur
    Lopez-Jarana, Paula
    Diaz-Castro, Carmen M.
    Rios-Carrasco, Blanca
    Vicente Rios-Santos, Jose
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (06) : 1124 - 1131
  • [35] Biomechanical evaluation of dental implants with three different designs: Removal torque and resonance frequency analysis in rabbits
    Gehrke, Sergio Alexandre
    Marin, Giovanni Wiel
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2015, 199 : 30 - 35
  • [36] Resonance frequency analysis of miniscrew implant stability
    Tseng, Yu-Chuan
    Pan, Chin-Yun
    Liu, Pao-Hsin
    Yang, Yi-Hsin
    Chang, Hong-Po
    Chen, Chun-Ming
    JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 64 - 69
  • [37] Resonance frequency analysis (RFA) and insertional torque (IT) stability comparisons of implants placed using osteotomes versus drilling techniques: A preliminary case study
    Xing, Yi
    Khandelwal, Namita
    Petrov, Sofia
    Drew, Howard J.
    Mupparapu, Mel
    QUINTESSENCE INTERNATIONAL, 2015, 46 (09): : 789 - 798
  • [38] Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants
    Yahya Açil
    Jan Sievers
    Aydin Gülses
    Mustafa Ayna
    Jörg Wiltfang
    Hendrik Terheyden
    Odontology, 2017, 105 : 347 - 353
  • [39] Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants
    Acil, Yahya
    Sievers, Jan
    Guelses, Aydin
    Ayna, Mustafa
    Wiltfang, Joerg
    Terheyden, Hendrik
    ODONTOLOGY, 2017, 105 (03) : 347 - 353
  • [40] Zirconia vs. Titanium Dental Implants: Primary Stability In-Vitro Analysis
    Arlucea, Nerea
    Brizuela-Velasco, Aritza
    Dieguez-Pereira, Markel
    Punset, Miquel
    Molmeneu, Meritxell
    Sanchez Lasheras, Fernando
    deLlanos-Lanchares, Hector
    Alvarez-Arenal, Angel
    MATERIALS, 2021, 14 (24)