Is Resonance Frequency Analysis a Reliable Evaluation for Primary Stability of Implants Without Apical Contact?

被引:0
|
作者
Ozyurt, Anil [1 ,3 ]
Bilmenoglu, Caglar [2 ]
机构
[1] Dokuz Eylul Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Izmir, Turkey
[2] Trakya Univ, Dept Prosthodont, Fac Dent, Edirne, Turkey
[3] Trakya Univ, Dept Oral & Maxillofacial Surg, Fac Dent, Edirne, Turkey
关键词
apically contactless; dental implant; primary stability; resonance frequency analysis; SINUS FLOOR ELEVATION; ATROPHIC POSTERIOR MAXILLA; SURGICAL TECHNIQUE; INSERTION TORQUE; COLLAR DESIGN; BONE; PLACEMENT; SURGERY; SURFACE; SHAPE;
D O I
10.11607/jomi.9480
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The primary stability of dental implants is one of the most crucial factors for providing long-term success of osseointegration. Vertical deficiencies, such as those due to maxillary sinus pneumatization, may cause a severe vertical limitation to residual bone height. This study aimed to examine the primary stabilization of implants without apical contacts. Materials and Methods: Eighty bone-level implants (4.1-mm diameter/10-mm length) were placed into polyurethane test blocks without apical contacts. According to coronal bone-to-implant contact, groups were set as 4,6, 8, and 10 mm, respectively. Resonance frequency analysis (RFA) using a SmartPeg was performed separately toward the transversal and horizontal axes by two independent researchers. Data were statistically compared for interobserver and among groups. Results: Interobserver reliability varied from moderate to excellent (intraclass correlation coefficient [ICC]: 0.629 to 0.985). There were no significant differences among the 6 mm, 8 mm, and 10 mm groups, although the 4 mm group showed the significantly lowest stability (P < .001). Transversal and longitudinal measurements of the same groups did not show a parallel correlation statistically. Conclusion: RFA values may be affected by the finger torque in tightening of the SmartPeg among different researchers. Fully placed implants did not significantly show the highest stability among various apically contactless groups. Consequently, RFA should not be used alone to evaluate primary stability for implants without an apical contact.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 50 条
  • [21] Primary Stability of Cylindrical and Conical Dental Implants in Relation to Insertion TorqueA Comparative Ex Vivo Evaluation
    Staedt, Henning
    Palarie, Victor
    Staedt, Arne
    Wolf, Jens M.
    Lehmann, Karl Martin
    Ottl, Peter
    Kaemmerer, Peer W.
    IMPLANT DENTISTRY, 2017, 26 (02) : 250 - 255
  • [22] Can resonance frequency analysis detect narrow marginal bone defects around dental implants? An ex vivo animal pilot study
    Yao, C. J.
    Ma, L.
    Mattheos, N.
    AUSTRALIAN DENTAL JOURNAL, 2017, 62 (04) : 433 - 439
  • [23] A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants
    Turkyilmaz, I.
    JOURNAL OF ORAL REHABILITATION, 2006, 33 (10) : 754 - 759
  • [24] Effects of buccal bi-cortical anchorages on primary stability of dental implants: a numerical approach of natural frequency analysis
    Wang, K.
    Li, D. H.
    Guo, J. F.
    Liu, B. L.
    Shi, S. Q.
    JOURNAL OF ORAL REHABILITATION, 2009, 36 (04) : 284 - 291
  • [25] Evaluation of primary and secondary stability of titanium implants using different surgical techniques
    Tabassum, Afsheen
    Meijer, Gert J.
    Walboomers, X. Frank
    Jansen, John A.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (04) : 487 - 492
  • [26] Stability changes of miniscrew implants over time A pilot resonance frequency analysis
    Ure, Derid S.
    Oliver, Donald R.
    Kim, Ki Beom
    Melo, Ana Claudia
    Buschang, Peter H.
    ANGLE ORTHODONTIST, 2011, 81 (06) : 994 - 1000
  • [27] Resonance Frequency Analysis of 208 Straumann Dental Implants During the Healing Period
    Guler, Ahmet Umut
    Sumer, Mahmut
    Duran, Ibrahim
    Sandikci, Elif Ozen
    Telcioglu, Nazife Tuba
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (02) : 161 - 168
  • [28] Evaluation of postoperative dental implant primary stability using 3D finite element analysis
    Pammer, David
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (03) : 280 - 287
  • [29] Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis
    Ivanjac, Filip
    Konstantinovic, Vitomir S.
    Lazic, Vojkan
    Dordevic, Igor
    Ihde, Stefan
    JOURNAL OF CRANIOFACIAL SURGERY, 2016, 27 (02) : E185 - E189
  • [30] The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study
    Mikic, Mirko
    Vlahovic, Zoran
    Stevanovic, Momir
    Arsic, Zoran
    Mladenovic, Rasa
    TOMOGRAPHY, 2022, 8 (03) : 1293 - 1306