Influence of Intracanal Materials in Vertical Root Fracture Pathway Detection with Cone-beam Computed Tomography

被引:16
作者
Dutra, Kamile Leonardi [1 ]
Pacheco-Pereira, Camila [2 ]
Bortoluzzi, Eduardo Antunes [3 ]
Flores-Mir, Carlos [4 ]
Lagravere, Manuel O. [4 ]
Correa, Marcio [5 ]
机构
[1] Minist Educ Brazil, CAPES Fdn, Brasilia, DF, Brazil
[2] Univ Alberta, Fac Med & Dent, Dept Radiol, Edmonton, AB, Canada
[3] Univ Fed Santa Catarina, Dept Endodont, Florianopolis, SC, Brazil
[4] Univ Alberta, Fac Med & Dent, Orthodont Grad Program, Dept Dent, Edmonton, AB, Canada
[5] Univ Fed Santa Catarina, Dept Radiol, Florianopolis, SC, Brazil
关键词
Cone-beam computed tomography; diagnostic accuracy; endodontic treatment; vertical root fracture; ENDODONTICALLY TREATED TEETH; DIAGNOSIS; METAANALYSIS; SCAN;
D O I
10.1016/j.joen.2017.02.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Investigating the vertical root fracture (VRF) pathway under different clinical scenarios may help to diagnose this condition properly. We aimed to determine the capability and intrareliability of VRF pathway detection through cone-beam computed tomographic (CBCT) imaging as well as analyze the influence of different intracanal and crown materials. Methods: VRFs were mechanically induced in 30 teeth, and 4 clinical situations were reproduced in vitro: no filling, gutta-percha, post, and metal crown. A Prexion (San Mateo, CA) 3-dimensional tomographic device was used to generate 104 CBCT scans. The VRF pathway was determined by using landmarks in the Avizo software (Version 8.1; FEI Visualization Sciences Group, Burlington, MA) by 1 observer repeated 3 times. Analysis of variance and post hoc tests were applied to compare groups. Results: Intrareliability demonstrated an excellent agreement (intraclass correlation coefficient mean = 0.93). Descriptive analysis showed that the fracture line measurement was smaller in the post and metal crown groups than in the no-filling and gutta-percha groups. The 1-way analysis of variance test found statistically significant differences among the groups measurements. The Bonferroni correction showed statistically significant differences related to the no-filling and gutta-percha groups versus the post and metal crown groups. Conclusions: The VRF pathway can be accurately detected in a nonfilled tooth using limited field of view CBCT imaging. The presence of gutta-percha generated a low beam hardening artifact that did not hinder the VRF extent. The presence of an intracanal gold post made the fracture line appear smaller than it really was in the sagittal images; in the axial images, a VRF was only detected when the apical third was involved. The presence of a metal crown did not generate additional artifacts on the root surface compared to the intracanal gold post by itself.
引用
收藏
页码:1170 / 1175
页数:6
相关论文
共 26 条
[1]  
American Association of Endodontics
[2]  
colleagues of excellence, 2008, CRACK CRACK TOOTH CO
[3]   Use of Cone Beam Computed Tomography in Endodontics 2015 Update [J].
Fayad, Mohamed I. ;
Levin, Martin D. ;
Rubinstein, Richard A. ;
Hirschberg, Craig S. ;
Nair, Madhu ;
Benavides, Erika ;
Barghan, Sevin ;
Ruprecht, Axel .
JOURNAL OF ENDODONTICS, 2015, 41 (09) :1393-1396
[4]   Vertical root fracture in nonendodontically treated teeth - A clinical report of 64 cases in Chinese patients [J].
Chan, CP ;
Tseng, SC ;
Lin, CP ;
Huang, CC ;
Tsai, TP ;
Chen, CC .
JOURNAL OF ENDODONTICS, 1998, 24 (10) :678-681
[5]   A demographic analysis of vertical root fractures [J].
Cohen, Stephen ;
Berman, Louis H. ;
Blanco, Lucia ;
Bakland, Leif ;
Kim, Jay S. .
JOURNAL OF ENDODONTICS, 2006, 32 (12) :1160-1163
[6]   Cone beam computed tomography for the diagnosis of vertical root fractures: a systematic review of the literature and meta-analysis [J].
Corbella, Stefano ;
Del Fabbro, Massimo ;
Tamse, Aviad ;
Rosen, Eyal ;
Tsesis, Igor ;
Taschieri, Silvio .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 118 (05) :593-602
[7]   ALARA still applies [J].
Farman, AG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2005, 100 (04) :395-397
[8]   In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT) [J].
Fisekcioglu, Erdogan ;
Dolekoglu, Semanur ;
Ilguy, Mehmet ;
Ersan, Nilufer ;
Ilguy, Dilhan .
IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
[9]   Comparison of in vivo 3D cone-beam computed tomography tooth volume measurement protocols [J].
Forst D. ;
Nijjar S. ;
Flores-Mir C. ;
Carey J. ;
Secanell M. ;
Lagravere M. .
Progress in Orthodontics, 15 (1) :69
[10]   Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2009, 35 (05) :719-722