Hypoperfusion in nucleus accumbens in chronic migraine using 3D pseudo-continuous arterial spin labeling imaging MRI

被引:9
|
作者
Liu, Mengqi [1 ,2 ]
Sun, Yijie [1 ]
Li, Xin [1 ,3 ]
Chen, Zhiye [1 ,3 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Radiol, Sanya 572013, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing 100853, Peoples R China
[3] Southern Med Univ, Sch Clin Med 2, Guangzhou 510515, Peoples R China
关键词
Arterial spin labelling; Brain; Chronic migraine; Magnetic resonance imaging; Nucleus accumbens; Perfusion imaging; CEREBRAL PERFUSION; PAIN; BRAIN; INVOLVEMENT; VOLUME;
D O I
10.1186/s10194-022-01444-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Nucleus accumbens (NAcc) played an important role in pain mediation, and presents changes of neuronal plasticity and functional connectivity. However, less is known about altered perfusion of NAcc in chronic migraine (CM). The aim of this study is to investigate the altered perfusion of the NAcc in CM using a MR three-dimensional pseudo-continuous arterial spin labeling (3D PCASL) imaging. Methods Thirteen CM patients and 15 normal controls (NC) were enrolled and underwent 3D PCASL and brain structural imaging. The cerebral blood flow (CBF) images were co-registered with the brain structural images, and the volume and CBF value of NAcc were extracted from the raw brain structural images and co-registered CBF images using an individual NAcc mask, which was obtained from the AAL3 template under transformation by the inverse deformation field generated from the segmentation of the brain structural images. The independent sample t test and receiver operating characteristic (ROC) curve was used to investigate the altered volume and perfusion of the NAcc in CM patients. Results There was no significant difference for the volume of bilateral NAccs between CM and NC (p > 0.05). CM presented a lower CBF value (49.34 +/- 6.09 ml/100 mg/min) compared with that of NC (55.83 +/- 6.55 ml/100 mg/min) in left NAcc (p = 0.01), while right NAcc showed no significant difference between CM and NC (p = 0.11). ROC analysis identified that the area under the curve was 0.73 (95CI% 0.53-0.88) with cut-off value 48.63 ml/100 mg/min with sensitivity 50.00% and specificity 93.33%. The correlation analysis found a negative correlation between the CBF value of the left NAcc and VAS score (r = -0.61, p = 0.04). Conclusion Hypoperfusion of the left NAcc was observed in CM, which could be considered as a potential diagnostic imaging biomarker in CM.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [22] Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla
    Sigurdsson, Sigurdur
    Forsberg, Lars
    Aspelund, Thor
    van der Geest, Rob J.
    van Buchem, Mark A.
    Launer, Lenore J.
    Gudnason, Vilmundur
    van Osch, Matthias J.
    PLOS ONE, 2015, 10 (12):
  • [23] In vivo visualization of the PICA perfusion territory with super-selective pseudo-continuous arterial spin labeling MRI
    Hartkamp, Nolan S.
    De Cocker, Laurens J.
    Helle, Michael
    van Osch, Matthias J. P.
    Kappelle, L. Jaap
    Bokkers, Reinoud P. H.
    Hendrikse, Jeroen
    NEUROIMAGE, 2013, 83 : 58 - 65
  • [24] Influence of post-label delay time on the performance of 3D pseudo-continuous arterial spin labeling magnetic resonance imaging in the characterization of parotid gland tumors
    Hu, Hao
    Chen, Lu
    Zhu, Liu-Ning
    Chen, Wei
    Su, Guo-Yi
    Dou, Weiqiang
    Bu, Shou-Shan
    Wu, Fei-Yun
    Xu, Xiao-Quan
    EUROPEAN RADIOLOGY, 2022, 32 (02) : 1087 - 1094
  • [25] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    Johan N. van der Meer
    Dennis F. R. Heijtel
    Guus van Hest
    Geert-Jan Plattèl
    Matthijs J. P. van Osch
    Eus J. W. van Someren
    Ed T. vanBavel
    Aart J. Nederveen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2014, 27 : 269 - 276
  • [26] Influence of post-label delay time on the performance of 3D pseudo-continuous arterial spin labeling magnetic resonance imaging in the characterization of parotid gland tumors
    Hao Hu
    Lu Chen
    Liu-Ning Zhu
    Wei Chen
    Guo-Yi Su
    Weiqiang Dou
    Shou-Shan Bu
    Fei-Yun Wu
    Xiao-Quan Xu
    European Radiology, 2022, 32 : 1087 - 1094
  • [27] Evaluation of the degree of arteriovenous shunting in intracranial arteriovenous malformations using pseudo-continuous arterial spin labeling magnetic resonance imaging
    Sunwoo, Leonard
    Sohn, Chul-Ho
    Lee, Jong Young
    Yi, Kyung Sik
    Yun, Tae Jin
    Choi, Seung Hong
    Cho, Young Dae
    Kim, Ji-hoon
    Park, Sun-Won
    Han, Moon Hee
    Paek, Sun Ha
    Kim, Yong Hwy
    Kim, Jin Wook
    Chung, Hyun-Tai
    Kim, Dong Gyu
    NEURORADIOLOGY, 2015, 57 (08) : 775 - 782
  • [28] Pseudo-continuous arterial spin labeling quantifies cerebral blood flow in patients with acute ischemic stroke and chronic lacunar stroke
    Guo, LingFei
    Zhang, Qun
    Ding, Linda
    Liu, Kai
    Ding, Kevin
    Jiang, Chuanwu
    Liu, Cheng
    Li, Kuncheng
    Cui, Li
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2014, 125 : 229 - 236
  • [29] Comparison of 2D simultaneous multi-slice and 3D GRASE readout schemes for pseudo-continuous arterial spin labeling of cerebral perfusion at 3 T
    Manjunathan Nanjappa
    Thomas Troalen
    Josef Pfeuffer
    Bénédicte Maréchal
    Tom Hilbert
    Tobias Kober
    Fabien C. Schneider
    Pierre Croisille
    Magalie Viallon
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 437 - 450
  • [30] Repeatability of perfusion measurements in adult gliomas using pulsed and pseudo-continuous arterial spin labelling MRI
    Amirah Faisal Alsaedi
    David Lee Thomas
    Enrico De Vita
    Jasmina Panovska-Griffiths
    Sotirios Bisdas
    Xavier Golay
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 113 - 125