Hypoperfusion in nucleus accumbens in chronic migraine using 3D pseudo-continuous arterial spin labeling imaging MRI

被引:9
|
作者
Liu, Mengqi [1 ,2 ]
Sun, Yijie [1 ]
Li, Xin [1 ,3 ]
Chen, Zhiye [1 ,3 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Radiol, Sanya 572013, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing 100853, Peoples R China
[3] Southern Med Univ, Sch Clin Med 2, Guangzhou 510515, Peoples R China
关键词
Arterial spin labelling; Brain; Chronic migraine; Magnetic resonance imaging; Nucleus accumbens; Perfusion imaging; CEREBRAL PERFUSION; PAIN; BRAIN; INVOLVEMENT; VOLUME;
D O I
10.1186/s10194-022-01444-6
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Nucleus accumbens (NAcc) played an important role in pain mediation, and presents changes of neuronal plasticity and functional connectivity. However, less is known about altered perfusion of NAcc in chronic migraine (CM). The aim of this study is to investigate the altered perfusion of the NAcc in CM using a MR three-dimensional pseudo-continuous arterial spin labeling (3D PCASL) imaging. Methods Thirteen CM patients and 15 normal controls (NC) were enrolled and underwent 3D PCASL and brain structural imaging. The cerebral blood flow (CBF) images were co-registered with the brain structural images, and the volume and CBF value of NAcc were extracted from the raw brain structural images and co-registered CBF images using an individual NAcc mask, which was obtained from the AAL3 template under transformation by the inverse deformation field generated from the segmentation of the brain structural images. The independent sample t test and receiver operating characteristic (ROC) curve was used to investigate the altered volume and perfusion of the NAcc in CM patients. Results There was no significant difference for the volume of bilateral NAccs between CM and NC (p > 0.05). CM presented a lower CBF value (49.34 +/- 6.09 ml/100 mg/min) compared with that of NC (55.83 +/- 6.55 ml/100 mg/min) in left NAcc (p = 0.01), while right NAcc showed no significant difference between CM and NC (p = 0.11). ROC analysis identified that the area under the curve was 0.73 (95CI% 0.53-0.88) with cut-off value 48.63 ml/100 mg/min with sensitivity 50.00% and specificity 93.33%. The correlation analysis found a negative correlation between the CBF value of the left NAcc and VAS score (r = -0.61, p = 0.04). Conclusion Hypoperfusion of the left NAcc was observed in CM, which could be considered as a potential diagnostic imaging biomarker in CM.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Hypoperfusion in nucleus accumbens in chronic migraine using 3D pseudo-continuous arterial spin labeling imaging MRI
    Mengqi Liu
    Yijie Sun
    Xin Li
    Zhiye Chen
    The Journal of Headache and Pain, 2022, 23
  • [2] Hypoperfusion of Amygdala in Chronic Migraine: An Exploratory Quantitative Perfusion Imaging Using 3D Pseudo-Continuous Arterial Spin Labeling
    Jiang, Yujiao
    Li, Xin
    Zhao, Shuqiang
    Liu, Mengqi
    Chen, Zhiye
    CURRENT MEDICAL IMAGING, 2024, 20
  • [3] Hypoperfusion of periaqueductal gray as an imaging biomarker in chronic migraine beyond diagnosis: A 3D pseudocontinuous arterial spin labeling MR imaging
    Huang, Pan
    Wu, Mei
    Liu, Mengqi
    Li, Xin
    Jiang, Yujiao
    Chen, Zhiye
    BRAIN AND BEHAVIOR, 2024, 14 (09):
  • [4] Decreased Cerebral Perfusion in Chronic Migraine: A Voxel-based Cerebral Blood Flow Analysis Using 3D Pseudo-continuous Arterial Spin Labeling
    Li X.
    Liu M.
    Zhao S.
    Chen Z.
    Current Medical Imaging, 2024, 20
  • [5] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Zhiye Chen
    Xiaoyan Chen
    Mengyu Liu
    Mengqi Liu
    Lin Ma
    Shengyuan Yu
    The Journal of Headache and Pain, 2018, 19
  • [6] Evaluation of gray matter perfusion in episodic migraine using voxel-wise comparison of 3D pseudo-continuous arterial spin labeling
    Chen, Zhiye
    Chen, Xiaoyan
    Liu, Mengyu
    Liu, Mengqi
    Ma, Lin
    Yu, Shengyuan
    JOURNAL OF HEADACHE AND PAIN, 2018, 19
  • [7] Acoustic noise reduction in pseudo-continuous arterial spin labeling (pCASL)
    van der Meer, Johan N.
    Heijtel, Dennis F. R.
    van Hest, Guus
    Plattel, Geert-Jan
    van Osch, Matthijs J. P.
    van Someren, Eus J. W.
    vanBavel, Ed T.
    Nederveen, Aart J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2014, 27 (03) : 269 - 276
  • [8] Selective multivessel labeling approach for perfusion territory imaging in pseudo-continuous arterial spin labeling
    Helle, Michael
    Ruefer, Susanne
    van Osch, Matthias J. P.
    Jansen, Olav
    Norris, David G.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 214 - 219
  • [9] Can 3D pseudo-continuous arterial spin labeling perfusion imaging be applied to predict early response to chemoradiotherapy in patients with advanced nasopharyngeal carcinoma?
    Sun, Zongqiong
    Hu, Shudong
    Xue, Qian
    Jin, Linfang
    Huang, Jianfeng
    Dou, Weiqiang
    RADIOTHERAPY AND ONCOLOGY, 2021, 160 : 97 - 106
  • [10] Characterization of Skull Base Lesions Using Pseudo-Continuous Arterial Spin Labeling
    Geerts, B.
    Leclercq, D.
    du Montcel, S. Tezenas
    Law-ye, B.
    Gerber, S.
    Bernardeschi, D.
    Galanaud, D.
    Dormont, D.
    Pyatigorskaya, N.
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 75 - 86