Development of a Solid-Phase Extraction Method Based on Biocompatible Starch Polyurethane Polymers for GC-MS Analysis of Polybrominated Diphenyl Ethers in Ambient Water Samples

被引:1
|
作者
Zhang, Qian [1 ]
Okoli, Chukwunonso P. [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Geog Sci & Nat Resources Res, Beijing 100101, Peoples R China
[2] Alex Ekwueme Fed Univ, Dept Chem, Ndufu Alike 482131, Abakaliki, Nigeria
来源
MOLECULES | 2022年 / 27卷 / 10期
关键词
PBDEs; starch-based polyurethane polymer; SPE; GC-NCI-MS; TANDEM MASS-SPECTROMETRY; GAS-CHROMATOGRAPHY; ELECTRON-CAPTURE; ENVIRONMENTAL WATER; MICROEXTRACTION; TETRACYCLINE; ADSORPTION; REMOVAL;
D O I
10.3390/molecules27103253
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new solid-phase extraction (SPE) method for the extraction, enrichment, and analysis of eight polybrominated diphenyl ethers (PBDEs) in water was developed. The current approach involves using a cross-linked starch-based polymer as an extraction adsorbent and determining the PBDE analytes of interest using gas chromatography-mass spectrometry in negative chemical ionization mode (GC-NCI-MS). The starch-based polymer was synthesized by the reaction of soluble starch with 4,4 '-methylene-bis-phenyldiisocyanate as a cross-linking agent in dry dimethylformamide. Various parameters impacting extraction efficiencies, such as adsorbent quantity, sample volumes, elution solvents and volumes, and methanol content, were carefully optimized. The 500 mg of starch-based polymer as an adsorbent used to extract 1000 mL of spiked water, presented high extraction recoveries of eight PBDEs. The linearity of the extraction process was investigated in the range of 1-200 ng L-1 for BDE-28, 47, 99, 100, and 5-200 ng L-1 for BDE-153, 154, 183, and 209, with coefficients of determination (r2) exceeding 0.990 for all PBDEs. The limits of detection (LODs) ranged from 0.06 to 1.42 ng L-1 (S/N = 3) and the relative standard deviation values (RSD) were between 3.6 and 9.5 percent (n = 5) under optimum conditions. The method was successfully used to analyze river and lake water samples, where it exhibited acceptable recovery values of 71.3 to 104.2%. Considering the excellent analytical performance and comparative cost advantage, we recommend the developed starch-based SPE method for routine extraction and analysis of PBDEs in water media.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Determination of fluoroacetic acid in water and biological samples by GC-FID and GC-MS in combination with solid-phase microextraction
    Koryagina, Nadezhda L.
    Savelieva, Elena I.
    Khlebnikova, Natalia S.
    Goncharov, Nikolay V.
    Jenkins, Richard O.
    Radilov, Andrey S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (05) : 1395 - 1400
  • [32] Determination of fluoroacetic acid in water and biological samples by GC-FID and GC-MS in combination with solid-phase microextraction
    Nadezhda L. Koryagina
    Elena I. Savelieva
    Natalia S. Khlebnikova
    Nikolay V. Goncharov
    Richard O. Jenkins
    Andrey S. Radilov
    Analytical and Bioanalytical Chemistry, 2006, 386 : 1395 - 1400
  • [33] Graphene-assisted matrix solid-phase dispersion for extraction of polybrominated diphenyl ethers and their methoxylated and hydroxylated analogs from environmental samples
    Liu, Qian
    Shi, Jianbo
    Sun, Jianteng
    Thanh Wang
    Zeng, Lixi
    Zhu, Nali
    Jiang, Guibin
    ANALYTICA CHIMICA ACTA, 2011, 708 (1-2) : 61 - 68
  • [34] Occurrence of residual water within disk-based solid-phase extraction and its effect on GC-MS measurement of organic extracts of environmental samples
    Christine Erger
    Peter Balsaa
    Friedrich Werres
    Torsten C. Schmidt
    Analytical and Bioanalytical Chemistry, 2012, 403 : 2541 - 2552
  • [35] Occurrence of residual water within disk-based solid-phase extraction and its effect on GC-MS measurement of organic extracts of environmental samples
    Erger, Christine
    Balsaa, Peter
    Werres, Friedrich
    Schmidt, Torsten C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (09) : 2541 - 2552
  • [36] Development and Application of the Dispersive Solid-Phase Extraction Method Based on Molecular Imprinted Polymers for Removal of Matrix Components of Bivalve Shellfish Extracts in the GC-MS/MS Analysis of Amide/Dinitroaniline/Substituted Urea Herbicides
    Yu, Xin-ru
    Zhang, Ze-ming
    Li, Wei
    Zhang, Rong-rong
    Jiao, Hai-feng
    Zhao, Jian
    Sun, Ai-li
    Shi, Xi-zhi
    Chen, Jiong
    CHROMATOGRAPHIA, 2019, 82 (06) : 961 - 970
  • [37] Dispersive solid-phase extraction clean up combined with Soxhlet extraction for the determination of 16 PAHs in soil samples by GC-MS
    Nikolic, Jelena S.
    Jovanovic, Vesna P. Stankov
    Dimitrijevic, Marija V.
    Cvetkovic, Dragan J.
    Stanojevic, Ljiljana P.
    Nikolic, Ljubisa B.
    Mitic, Violeta D.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (02) : 112 - 123
  • [38] Automated solid-phase extraction for the determination of polybrominated diphenyl ethers and polychlorinated biphenyls in serum - application on archived Norwegian samples from 1977 to 2003
    Thomsen, Cathrine
    Liane, Veronica Horpestad
    Becher, Georg
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 846 (1-2): : 252 - 263
  • [39] Determination of Methadone and Metabolite (EDDP) in Urine Samples Using Solid Phase Extraction and GC-MS Analysis
    Hackett, Jeffery
    LC GC NORTH AMERICA, 2014, : 13 - 13
  • [40] Solid-phase extraction based in tube filled-magnetic carbon nanotubes coupled with GC-MS for analysis of polycyclic aromatic hydrocarbons in environmental samples
    Zhou, Chanyuan
    Meng, Tiao
    Yang, Chunyan
    Yang, Yike
    Chinese Journal of Analysis Laboratory, 2021, 40 (09) : 1015 - 1020