Comparison of two derivatization-based methods for solid-phase microextraction-gas chromatography-mass spectrometric determination of bisphenol A, bisphenol S and biphenol migrated from food cans

被引:197
作者
Vinas, P. [1 ]
Campillo, N. [1 ]
Martinez-Castillo, N. [1 ]
Hernandez-Cordoba, M. [1 ]
机构
[1] Univ Murcia, Dept Analyt Chem, Fac Chem, E-30071 Murcia, Spain
关键词
Gas chromatography-mass spectrometry; Solid-phase microextraction; On-fibre derivatisation; Bisphenols; Food cans; LIQUID-CHROMATOGRAPHY; ENDOCRINE DISRUPTORS; COLUMN SILYLATION; DIGLYCIDYL ETHER; CANNED FOODS; WASTE-WATER; EXTRACTION; COATINGS; SAMPLES; ALKYLPHENOLS;
D O I
10.1007/s00216-010-3464-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An environmentally friendly sample pretreatment system based on solid-phase microextraction (SPME) for the sensitive determination of bisphenol A (BPA), bisphenol S (BPS) and biphenol (BP) is described. Two derivatisation reactions to obtain volatile derivatives are compared. Derivatisation with acetic anhydride (AA) was performed in situ in a 5-mM Na2CO3/NaHCO3 buffer solution and analytes were extracted by direct immersion (DI) using a PA fibre (85 mu m) at 90 degrees C for 40 min with stirring at 1,500 rpm. For derivatisation with bis-(trimethylsilyl) trifluoroacetamide (BSTFA), the analytes were first extracted by DI using the PA fibre at 70 degrees C for 40 min with stirring at 500 rpm. The fibre was then removed, dried in a nitrogen stream for 2 min and introduced into the headspace of BSTFA at 50 degrees C for 30 s. After derivatisation, the analytes were desorbed in the injection port of the GC in the splitless mode at 280 degrees C for 4 min. The separation was carried out by coupling gas chromatography with mass spectrometry in the selected ion monitoring mode, GC-MS(SIM). The method allowed the determination of the migrating levels of bisphenols found in food cans, and it was validated for linearity, detection and quantitation limits, selectivity, accuracy and precision. Detection limits ranged from 3 to 16 pg mL(-1), depending on the compound, at a signal-to-noise ratio of 3. Recoveries obtained for spiked samples were satisfactory for all compounds. Levels of BPA were higher than those of BPS and the lowest contents were found for BP.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 45 条
[1]   Application of solid-phase extraction coupled with freezing-lipid filtration clean-up for the determination of endocrine-disrupting phenols in fish [J].
Ahn, Yun Gyong ;
Shin, Jeoung Hwa ;
Kim, Hye-Young ;
Khim, Jeehyeong ;
Lee, Mi-Kyouny ;
Hong, Jongki .
ANALYTICA CHIMICA ACTA, 2007, 603 (01) :67-75
[2]   Analytical methods for the determination of bisphenol A in food [J].
Ballesteros-Gomez, Ana ;
Rubio, Soledad ;
Perez-Bendito, Dolores .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :449-469
[3]   Determination of alkylphenols and bisphenol-A - A comparative investigation of functional polymer-coated membrane microextraction and solid-phase microextraction techniques [J].
Basheer, C ;
Parthiban, A ;
Jayaraman, A ;
Lee, HK ;
Valiyaveettil, S .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1087 (1-2) :274-282
[4]   Endocrine disrupting alkylphenols and bisphenol-A in coastal waters and supermarket seafood from Singapore [J].
Basheer, C ;
Lee, HK ;
Tan, KS .
MARINE POLLUTION BULLETIN, 2004, 48 (11-12) :1161-1167
[5]   Determination of bisphenol-A in reusable polycarbonate food-contact plastics and migration to food-simulating liquids [J].
Biles, JE ;
McNeal, TP ;
Begley, TH ;
Hollifield, HC .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (09) :3541-3544
[6]   Determination of bisphenol a migrating from epoxy can coatings to infant formula liquid concentrates [J].
Biles, JE ;
McNeal, TP ;
Begley, TH .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (12) :4697-4700
[7]   Trace analysis of technical nonylphenol, bisphenol A and 17α-ethinylestradiol in wastewater using solid-phase microextraction and gas chromatography-mass spectrometry [J].
Braun, P ;
Moeder, M ;
Schrader, S ;
Popp, P ;
Kuschk, P ;
Engewald, W .
JOURNAL OF CHROMATOGRAPHY A, 2003, 988 (01) :41-51
[8]   Determining leaching of bisphenol A from plastic containers by solid-phase microextraction and gas chromatography-mass spectrometry [J].
Chang, CM ;
Chou, CC ;
Lee, MR .
ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) :41-47
[9]   Optimization of the determination of polybrominated diphenyl ethers in human serum using solid-phase extraction and gas chromatography-electron capture negative ionization mass spectrometry [J].
Covaci, A ;
Voorspoels, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02) :216-223
[10]   Determination of bisphenol A in food-simulating liquids using LCED with a chemically modified electrode [J].
D'Antuono, A ;
Dall'Orto, VC ;
Lo Balbo, A ;
Sobral, S ;
Rezzano, I .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (03) :1098-1101