A portable array biosensor for food safety

被引:0
作者
Golden, JP [1 ]
Ngundi, MM [1 ]
Shriver-Lake, LC [1 ]
Taitt, CR [1 ]
Ligler, FS [1 ]
机构
[1] USN, Res Lab, Ctr Biomol Sci & Engn, Washington, DC 20375 USA
来源
NONDESTRUCTIVE SENSING FOR FOOD SAFETY, QUALITY, AND NATURAL RESOURCES | 2004年 / 5587卷
关键词
evanescent wave; biosensor; automated fluidies Fluorescence Imaging;
D O I
10.1117/12.570285
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
An array biosensor developed for simultaneous analysis of multiple samples has been utilized to develop assays for toxins and pathogens in a variety of foods. The biochemical component of the multi-analyte biosensor consists of a patterned array of biological recognition elements immobilized on the surface of a planar waveguide. A fluorescence assay is performed on the patterned surface, yielding an array of fluorescent spots, the locations of which are used to identify what analyte is present. Signal transduction is accomplished by means of a diode laser for fluorescence excitation, optical filters and a CCD camera for image capture. A laptop computer controls the miniaturized fluidics system and image capture. Results for four mycotoxin competition assays in buffer and food samples are presented.
引用
收藏
页码:241 / 244
页数:4
相关论文
共 9 条
[1]   A comparison of imaging methods for use in an array biosensor [J].
Golden, JP ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (09) :719-725
[2]  
NGUNDI MN, UNPUB ANAL CHEM
[3]   Array biosensor for simultaneous identification of bacterial, viral, and protein analytes [J].
Rowe, CA ;
Tender, LM ;
Feldstein, MJ ;
Golden, JP ;
Scruggs, SB ;
MacCraith, BD ;
Cras, JJ ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3846-3852
[4]   An array immunosensor for simultaneous detection of clinical analytes [J].
Rowe, CA ;
Scruggs, SB ;
Feldstein, MJ ;
Golden, JP ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 1999, 71 (02) :433-439
[5]   Array biosensor for detection of biohazards [J].
Rowe-Taitt, CA ;
Golden, JP ;
Feldstein, MJ ;
Cras, JJ ;
Hoffman, KE ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :785-794
[6]   Simultaneous detection of six biohazardous agents using a planar waveguide array biosensor [J].
Rowe-Taitt, CA ;
Hazzard, JW ;
Hoffman, KE ;
Cras, JJ ;
Golden, JP ;
Ligler, FS .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (11-12) :579-589
[7]   Demonstration of four immunoassay formats using the array biosensor [J].
Sapsford, KE ;
Charles, PT ;
Patterson, CH ;
Ligler, FS .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1061-1068
[8]   Detection of staphylococcal enterotoxin B in spiked food samples [J].
Shriver-Lake, LC ;
Shubin, YS ;
Ligler, FS .
JOURNAL OF FOOD PROTECTION, 2003, 66 (10) :1851-1856
[9]  
SHRIVERLAKE LC, IN PRESS JAOAC