Capillary electrochromatography on silica columns: factors influencing performance

被引:41
作者
Bartle, KD [1 ]
Carney, RA [1 ]
Cavazza, A [1 ]
Cikalo, MG [1 ]
Myers, P [1 ]
Robson, MM [1 ]
Roulin, SCP [1 ]
Sealey, K [1 ]
机构
[1] Univ Leeds, Sch Chem, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会;
关键词
electrochromatography; silica columns; reviews; capillary columns; stationary phases;
D O I
10.1016/S0021-9673(00)00150-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Much capillary electrochromatography (CEC) work is carried out on bonded silica packings which offer many advantages: the number of such packings which are available; the fact that the chemistry of bonding and the separation process are fairly well understood; and the possibility of the transfer to CEC of existing HPLC methods. Packing methods for the preparation of CEC columns have been investigated. The problems inherent in the use of burned-in frits remains an obstacle, but can be at least partially overcome by minimising the length and by silanisation. The influence of a variety of mobile phase variables on aspects of CEC is in agreement with theory for: ionic strength, organic content (including isoeluotropy), and pH. Temperature can be used as a variable to change column selectivity in CEC. The influence of pH on electroosmotic flow (EOF) by changing the degree of ionisation of residual silanol groups is similar for a wide range of neutral bonded groups, but is much less marked for bonded sulphonic acid groups. The EOF may be reversed for bonded groups containing nitrogen. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:279 / 290
页数:12
相关论文
共 50 条
[31]   Influence of the unpacked section on the chromatographic performance of duplex strong anion-exchange columns in capillary electrochromatography [J].
Byrne, CD ;
Smith, NW ;
Dearie, HS ;
Moffatt, F ;
Wren, SAC ;
Evans, KP .
JOURNAL OF CHROMATOGRAPHY A, 2001, 927 (1-2) :169-177
[32]   Overview of capillary electrophoresis and capillary electrochromatography [J].
Altria, KD .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :443-463
[33]   Instrumentation for capillary electrochromatography [J].
Steiner, F ;
Scherer, B .
JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) :55-83
[34]   Influence of ionic strength and organic modifier on performance in capillary electrochromatography on phenyl silica stationary phase [J].
Cahours, X ;
Morin, P ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 845 (1-2) :203-216
[35]   Photopolymerized sol-gel frits for packed columns in capillary electrochromatography [J].
Kato, M ;
Dulay, MT ;
Bennett, BD ;
Quirino, JP ;
Zare, RN .
JOURNAL OF CHROMATOGRAPHY A, 2001, 924 (1-2) :187-195
[36]   Magnetically immobilized frits for the preparation of packed columns used in capillary electrochromatography [J].
Wang, Hongling ;
Cao, Jingjing ;
Bi, Yanping ;
Chen, Lei ;
Wan, Qian-Hong .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (31) :5882-5887
[37]   Separation of histidine enantiomers by capillary electrochromatography with molecularly imprinted monolithic columns [J].
Sarkaya, Koray ;
Asir, Suleyman ;
Gokturk, Ilgim ;
Ektirici, Sisem ;
Yilmaz, Fatma ;
Yavuz, Handan ;
Denizli, Adil .
SEPARATION SCIENCE PLUS, 2020, 3 (06) :235-245
[38]   Development and characterization of hydrophobic organic monolithic columns for use in capillary electrochromatography [J].
Aguiar, Valeska Soares ;
Grespan Bottoli, Carla Beatriz .
MICROCHEMICAL JOURNAL, 2013, 109 :51-57
[39]   Repeatability of Octadecyl Methacrylate-Based Monolithic Columns for Capillary Electrochromatography [J].
Aguiar, Valeska Soares ;
Grespan Bottoli, Carla Beatriz .
INSTRUMENTATION SCIENCE & TECHNOLOGY, 2015, 43 (02) :139-155
[40]   Analysis of channel-geometry effects an separation efficiency in rectangular-capillary electrochromatography columns [J].
Zhang, X ;
Regnier, FE .