Much capillary electrochromatography (CEC) work is carried out on bonded silica packings which offer many advantages: the number of such packings which are available; the fact that the chemistry of bonding and the separation process are fairly well understood; and the possibility of the transfer to CEC of existing HPLC methods. Packing methods for the preparation of CEC columns have been investigated. The problems inherent in the use of burned-in frits remains an obstacle, but can be at least partially overcome by minimising the length and by silanisation. The influence of a variety of mobile phase variables on aspects of CEC is in agreement with theory for: ionic strength, organic content (including isoeluotropy), and pH. Temperature can be used as a variable to change column selectivity in CEC. The influence of pH on electroosmotic flow (EOF) by changing the degree of ionisation of residual silanol groups is similar for a wide range of neutral bonded groups, but is much less marked for bonded sulphonic acid groups. The EOF may be reversed for bonded groups containing nitrogen. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:279 / 290
页数:12
相关论文
共 50 条
  • [1] Packing columns for capillary electrochromatography
    Colón, LA
    Maloney, TD
    Fermier, AM
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 43 - 53
  • [2] Preparation of fritless packed silica columns for capillary electrochromatography
    Fujimoto, C
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (01): : 89 - 92
  • [3] Performance of single particle fritted capillary columns in electrochromatography
    Zhang, Bo
    Liu, Qing
    Yang, Lijun
    Wang, Qiuquan
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1272 : 136 - 140
  • [4] Preparation of various silica-based columns for capillary electrochromatography by in-column derivatization
    Suzuki, S
    Kuwahara, Y
    Makiura, K
    Honda, S
    JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (02) : 247 - 256
  • [5] Silicate entrapped columns - new columns designed for capillary electrochromatography
    Chirica, G
    Remcho, VT
    ELECTROPHORESIS, 1999, 20 (01) : 50 - 56
  • [6] Capillary electrochromatography in columns packed by centripetal forces
    Fermier, AM
    Colon, LA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1998, 10 (05) : 439 - 447
  • [7] Joule heating and determination of temperature in capillary electrophoresis and capillary electrochromatography columns
    Rathore, AS
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1037 (1-2) : 431 - 443
  • [8] Pseudo-electrokinetic packing of high efficiency columns for capillary electrochromatography
    Stol, R
    Mazereeuw, M
    Tjaden, UR
    van der Greef, J
    JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (02) : 293 - 298
  • [9] Design of the monolithic polymers used in capillary electrochromatography columns
    Svec, F
    Peters, EC
    Sykora, D
    Fréchet, JMJ
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 3 - 29
  • [10] Characterisation of electroosmotic flow in capillary electrochromatography columns
    Dearie, HS
    Spikmans, V
    Smith, NW
    Moffatt, F
    Wren, SAC
    Evans, KP
    JOURNAL OF CHROMATOGRAPHY A, 2001, 929 (1-2) : 123 - 131