Photomitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units

被引:82
|
作者
Uhl, A
Mills, RW
Jandt, KD
机构
[1] Univ Jena, Inst Mat Sci & Technol, D-07743 Jena, Germany
[2] Univ Bristol, Dept Oral & Dent Sci, Biomed Engn & Biomat Sci Sect, Bristol BS1 2LY, Avon, England
关键词
LED; depth of cure; Knoop hardness; light curing unit (LCU); dental composites;
D O I
10.1016/S0142-9612(02)00532-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Light curing units (LCUs) are used for the polymerization of dental composites. Recent trends in light curing technology include replacing the halogen LCUs with LCUs using light emitting diodes (LEDs) reducing curing times and varying the LCUs light output within a curing cycle. This study investigated the time dependence of the Knoop hardness and depth of cure of dental composites polymerized with a halogen LCU (Trilight) and two LED LCUs (the commercial Freelight and custom-made LED LCU prototype). The halogen LCU was used in the soft-start (exponential increase of output power) and standard mode. Four dental composites (Z100, Spectrum, Definite, Solitaire2) were selected, two of them (Definite, Solitaire2) contain co-initiators in addition to the standard photoinitiator camphorquinone. The depth of cure obtained with the Trilight in the standard mode was statistically significantly greater (p<0.05) than that obtained with the LED LCUs for all materials and curing times. The custom made LED LCU prototype (LED63) achieved a statistically significantly greater depth of cure than the commercial LED LCU Freelight for all materials and curing times. There was no statistical difference in Knoop hardness at the 95% confidence level at the surface of the 2 mm thick sample between the LED63 or Trilight (standard mode) for the composite Z100 for all times, and for Spectrum for 20 s and 40 s curing time. The composites containing co-initiators showed statistically significantly smaller hardness values at the top and bottom of the samples if LED LCUs were used instead of halogen LCUs. The experiment revealed that the depth of cure test does not and the Knoop hardness test does discriminate between LCUs, used for the polymerization of composites containing photoinitiators in addition to camphorquinone. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1787 / 1795
页数:9
相关论文
共 50 条
  • [31] Influence of curing tip distance on the composite Knoop hardness values
    Consani, S
    Sobrinho, LC
    Almeida, AA
    Sinhoreti, MAC
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 996 - 996
  • [32] SPECTRAL DISTRIBUTION OF VISIBLE-LIGHT CURING UNITS - EFFECT ON THE DEPTH OF CURE IN A DENTAL COMPOSITE RESIN
    HIROSE, T
    WAKASA, K
    YAMAKI, M
    JOURNAL OF MATERIALS SCIENCE, 1990, 25 (2B) : 1209 - 1213
  • [33] An evaluation of depth of cure with two lamps: a Knoop hardness study.
    Pelissier, B
    Castany, E
    Chazel, JC
    Valcarcel, J
    De Souffron, N
    Duret, F
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 525 - 525
  • [34] Comparison of halogen, plasma and LED curing units
    Nomoto, R
    McCabe, J
    Hirano, S
    OPERATIVE DENTISTRY, 2004, 29 (03) : 287 - 294
  • [35] Time dependence of composite shrinkage using halogen and LED light curing
    Uhl, A
    Mills, RW
    Rzanny, AE
    Jandt, KD
    DENTAL MATERIALS, 2005, 21 (03) : 278 - 286
  • [36] Evaluation of the Depth of Cure by Microhardness of Bulk-Fill Composites with Monowave and Polywave LED Light-Curing Units
    Thomaidis, Socratis
    Kampouropoulos, Dimitris
    Antoniadou, Maria
    Kakaboura, Afrodite
    APPLIED SCIENCES-BASEL, 2024, 14 (24):
  • [37] Composite hardness with intra and extra oral light curing units.
    Capilla, M
    Macchi, AR
    Macchi, RL
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 918 - 918
  • [38] Effectiveness of composite cure associated with different light curing units.
    Soh, MS
    Yap, AUJ
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 639 - 639
  • [39] The Influence of Different Light Curing Modes on the Depth of Cure of the Composite Resin
    Miljkovic, Nikola
    Dacic, Stefan
    Karuntanovic, Tamara
    Igic, Marko
    Dacic, Milica
    Dacic-Simonovic, Dragica
    ACTA FACULTATIS MEDICAE NAISSENSIS, 2018, 35 (01) : 58 - 64
  • [40] Correlation between Knoop hardness and cure degree of composite resins.
    Carvalho, CMLS
    Goes, MF
    Rosolen, M