Photomitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units

被引:82
|
作者
Uhl, A
Mills, RW
Jandt, KD
机构
[1] Univ Jena, Inst Mat Sci & Technol, D-07743 Jena, Germany
[2] Univ Bristol, Dept Oral & Dent Sci, Biomed Engn & Biomat Sci Sect, Bristol BS1 2LY, Avon, England
关键词
LED; depth of cure; Knoop hardness; light curing unit (LCU); dental composites;
D O I
10.1016/S0142-9612(02)00532-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Light curing units (LCUs) are used for the polymerization of dental composites. Recent trends in light curing technology include replacing the halogen LCUs with LCUs using light emitting diodes (LEDs) reducing curing times and varying the LCUs light output within a curing cycle. This study investigated the time dependence of the Knoop hardness and depth of cure of dental composites polymerized with a halogen LCU (Trilight) and two LED LCUs (the commercial Freelight and custom-made LED LCU prototype). The halogen LCU was used in the soft-start (exponential increase of output power) and standard mode. Four dental composites (Z100, Spectrum, Definite, Solitaire2) were selected, two of them (Definite, Solitaire2) contain co-initiators in addition to the standard photoinitiator camphorquinone. The depth of cure obtained with the Trilight in the standard mode was statistically significantly greater (p<0.05) than that obtained with the LED LCUs for all materials and curing times. The custom made LED LCU prototype (LED63) achieved a statistically significantly greater depth of cure than the commercial LED LCU Freelight for all materials and curing times. There was no statistical difference in Knoop hardness at the 95% confidence level at the surface of the 2 mm thick sample between the LED63 or Trilight (standard mode) for the composite Z100 for all times, and for Spectrum for 20 s and 40 s curing time. The composites containing co-initiators showed statistically significantly smaller hardness values at the top and bottom of the samples if LED LCUs were used instead of halogen LCUs. The experiment revealed that the depth of cure test does not and the Knoop hardness test does discriminate between LCUs, used for the polymerization of composites containing photoinitiators in addition to camphorquinone. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1787 / 1795
页数:9
相关论文
共 50 条
  • [11] Cure depths with LED light curing units
    Nick Silikas
    British Dental Journal, 2002, 193 (8) : 455 - 455
  • [12] Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units
    Polydorou, Olga
    Manolakis, Allexandros
    Hellwig, Ehnar
    Hahn, Petra
    CLINICAL ORAL INVESTIGATIONS, 2008, 12 (01) : 45 - 51
  • [13] Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units
    Olga Polydorou
    Alexandros Manolakis
    Elmar Hellwig
    Petra Hahn
    Clinical Oral Investigations, 2008, 12 : 45 - 51
  • [14] Influence of curing tip distance on resin composite Knoop Hardness Number, using three different light curing units
    Caldas, DBM
    Almeida, JB
    Correr-Sobrinho, L
    Sinhoreti, MAC
    Consani, S
    OPERATIVE DENTISTRY, 2003, 28 (03) : 315 - 320
  • [16] Cure degree and hardness Knoop composite resin
    Carvalho, CMLS
    De Góes, MF
    Peres, PEC
    Sinhoreti, MAC
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 444 - 444
  • [17] Effects of irradiance, wavelength, and thermal emission of different light curing units on the Knoop and vickers hardness of a composite resin
    Torno, Vladja
    Soares, Paulo
    Martin, Juliana M. H.
    Mazur, Rui F.
    Souza, Evelise M.
    Vieira, Sergio
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 85B (01) : 166 - 171
  • [18] Deep cure and hardness Knoop of composite resin
    Carvalho, CMLS
    De Goes, MF
    Peres, PEC
    Sinhoreti, MAC
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1155 - 1155
  • [19] Effect of a LED versus halogen light cure polymerization on the curing characteristics of three composite resins
    Besnault, C
    Pradelle-Plasse, N
    Picard, B
    Colon, P
    AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (05): : 323 - 328
  • [20] Composite depth of cure with halogen and blue LED technology.
    Mills, RW
    Jandt, KD
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 640 - 640