Photomitiator dependent composite depth of cure and Knoop hardness with halogen and LED light curing units

被引:82
|
作者
Uhl, A
Mills, RW
Jandt, KD
机构
[1] Univ Jena, Inst Mat Sci & Technol, D-07743 Jena, Germany
[2] Univ Bristol, Dept Oral & Dent Sci, Biomed Engn & Biomat Sci Sect, Bristol BS1 2LY, Avon, England
关键词
LED; depth of cure; Knoop hardness; light curing unit (LCU); dental composites;
D O I
10.1016/S0142-9612(02)00532-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Light curing units (LCUs) are used for the polymerization of dental composites. Recent trends in light curing technology include replacing the halogen LCUs with LCUs using light emitting diodes (LEDs) reducing curing times and varying the LCUs light output within a curing cycle. This study investigated the time dependence of the Knoop hardness and depth of cure of dental composites polymerized with a halogen LCU (Trilight) and two LED LCUs (the commercial Freelight and custom-made LED LCU prototype). The halogen LCU was used in the soft-start (exponential increase of output power) and standard mode. Four dental composites (Z100, Spectrum, Definite, Solitaire2) were selected, two of them (Definite, Solitaire2) contain co-initiators in addition to the standard photoinitiator camphorquinone. The depth of cure obtained with the Trilight in the standard mode was statistically significantly greater (p<0.05) than that obtained with the LED LCUs for all materials and curing times. The custom made LED LCU prototype (LED63) achieved a statistically significantly greater depth of cure than the commercial LED LCU Freelight for all materials and curing times. There was no statistical difference in Knoop hardness at the 95% confidence level at the surface of the 2 mm thick sample between the LED63 or Trilight (standard mode) for the composite Z100 for all times, and for Spectrum for 20 s and 40 s curing time. The composites containing co-initiators showed statistically significantly smaller hardness values at the top and bottom of the samples if LED LCUs were used instead of halogen LCUs. The experiment revealed that the depth of cure test does not and the Knoop hardness test does discriminate between LCUs, used for the polymerization of composites containing photoinitiators in addition to camphorquinone. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1787 / 1795
页数:9
相关论文
共 50 条
  • [1] Halogen and LED light curing of composite: temperature increase and Knoop hardness
    L. F. Schneider
    S. Consani
    L. Correr-Sobrinho
    A. B. Correr
    M. A. Sinhoreti
    Clinical Oral Investigations, 2006, 10 : 66 - 71
  • [2] Halogen and LED light curing of composite: Temperature increase and Knoop hardness
    Schneider, LF
    Consani, S
    Correr-Sobrinho, L
    Correr, AB
    Sinhoreti, MA
    CLINICAL ORAL INVESTIGATIONS, 2006, 10 (01) : 66 - 71
  • [3] Curing depth of composite resin light cured by LED and halogen light-curing units
    Calixto, L. R.
    Lima, D. M.
    Queiroz, R. S.
    Rastelli, A. N. S.
    Bagnato, V. S.
    Andrade, M. F.
    LASER PHYSICS, 2008, 18 (11) : 1365 - 1369
  • [4] Light emitting diode (LED) and halogen curing - Composite depth of cure.
    Mills, RW
    Jandt, KD
    Blackwell, GB
    Ashworth, SH
    JOURNAL OF DENTAL RESEARCH, 1999, 78 (05) : 1053 - 1053
  • [5] Knoop hardness depth profiles and compressive strength of selected dental composites polymerized with halogen and LED light curing technologies
    Uhl, A
    Mills, RW
    Vowles, RW
    Jandt, KD
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (06): : 729 - 738
  • [6] Evaluation of composite resin depth of cure photopolymerized by two light curing unit: Halogen and LED.
    Vieira, LCC
    Bernardon, JK
    Lopes, GC
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 185 - 185
  • [7] Composite depth of cure and hardness using two LED curing lights.
    Munoz, C. A.
    Dahlke, K.
    Sy-Munoz, J.
    Dunn, J. R.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B200 - B200
  • [8] Effect of LED or halogen curing lights on Knoop hardness in posterior composites.
    Vandewalle, KS
    Ferracane, J
    Ly, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A486 - A486
  • [9] Effect of LED curing light on composite resin depth of cure.
    Dialani, N
    Sung, E
    Caputo, AA
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A86 - A86
  • [10] Depth of cure of composite resin with two light-curing units
    Dannheimer, MFG
    Marais, JT
    Germishuys, PJ
    Borman, JW
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1205 - 1205