Osteon pullout in the equine third metacarpal bone: effects of ex vivo fatigue

被引:64
作者
Hiller, LP
Stover, SM
Gibson, VA
Gibeling, JC
Prater, CS
Hazelwood, SJ
Yeh, OC
Martin, RB
机构
[1] Univ Calif Davis, Sch Med, Orthopaed Res Labs, Davis, CA 95616 USA
[2] Univ Calif Davis, Sch Vet Med, JD Wheat Vet Orthoped Res Lab, Davis, CA 95616 USA
[3] Univ Calif Davis, Coll Engn, Dept Chem Engn & Mat Sci, Davis, CA 95616 USA
关键词
fatigue; fracture; osteon; horse; remodeling;
D O I
10.1016/S0736-0266(02)00232-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
An important concept in bone mechanics is that osteons influence mechanical properties in several ways, including contributing to toughness and fatigue strength by debonding from the interstitial matrix so as to "bridge" developing cracks. Observations of "pulled out" osteons on fracture surfaces are thought to be indicative of such behavior. We tested the hypothesis that osteon pullout varies with mode of loading (fatigue vs. monotonic), cortical region, elastic modulus, and fatigue life. Mid-diaphseal beams from the dorsal, medial, and lateral regions of the equine third metacarpal bone were fractured in four point bending by monotonic loading to failure under deflection control, with or without 10(5) cycles of previous fatigue loading producing 5000 microstrain (15-20% of the expected failure strain) on the first cycle; or sinusoidal fatigue loading to failure, under load or deflection control, with the initial cycle producing 10,000 microstrain (30-40% of the expected failure strain). Using scanning electron microscopy, percent fracture surface area exhibiting osteon pullout (%OP.Ar) was measured. Monotonically loaded specimens and the compression side of fatigue fracture surfaces exhibited no osteon pullout. In load-controlled fatigue, pullout was present on the tension side of fracture surfaces, was regionally dependent (occurring to a greater amount dorsally), and was correlated negatively with elastic modulus and positively with fatigue life. Regional variation in %OP.Ar was also significant for the pooled (load and deflection controlled) fatigue specimens. %OP.Ar was nearly significantly greater in deflection controlled fatigue specimens than in load-controlled specimens (p = 0.059). The data suggest that tensile fatigue loading of cortical bone eventually introduces damage that results in osteonal debonding and pullout, which is also associated with increased fatigue life via mechanisms that are not yet clear. (C) 2003 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 25 条
  • [1] BEHIRI JC, 1987, BIOMECHANICS BASIC A
  • [2] BONE STRESS IN THE HORSE FORELIMB DURING LOCOMOTION AT DIFFERENT GAITS - A COMPARISON OF 2 EXPERIMENTAL METHODS
    BIEWENER, AA
    THOMASON, J
    GOODSHIP, A
    LANYON, LE
    [J]. JOURNAL OF BIOMECHANICS, 1983, 16 (08) : 565 - 576
  • [3] BONFIELD W, 1989, APPL FRACTURE MECH C, P615
  • [4] COMPOSITION OF THE CEMENT LINE AND ITS POSSIBLE MECHANICAL ROLE AS A LOCAL INTERFACE INHUMAN COMPACT-BONE
    BURR, DB
    SCHAFFLER, MB
    FREDERICKSON, RG
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (11) : 939 - &
  • [5] COOKE FW, 1973, J BIOMED MATER RES, V4, P383
  • [6] CORANDON G, 1986, J BIOMECH, V19, P207
  • [7] DAVIES HMS, 1993, ACTA ANAT, P146
  • [8] Fatigue behavior of the equine third metacarpus: Mechanical property analysis
    Gibson, VA
    Stover, SM
    Martin, RB
    Gibeling, TC
    Willits, NH
    Gustafson, MB
    Griffin, LV
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1995, 13 (06) : 861 - 868
  • [9] GIBSON VA, 2000, FATIGUE BEHAV EQUINE
  • [10] CHARACTERIZING BONE STRAIN DISTRIBUTIONS INVIVO USING 3 TRIPLE ROSETTE STRAIN-GAUGES
    GROSS, TS
    MCLEOD, KJ
    RUBIN, CT
    [J]. JOURNAL OF BIOMECHANICS, 1992, 25 (09) : 1081 - 1087