SLIM (slit lamp image mosaicing): handling reflection artifacts

被引:6
作者
Prokopetc, Kristina [1 ,2 ]
Bartoli, Adrien [2 ]
机构
[1] Quantel Med, 11 Rue Bois Joli, F-63808 Cournon Auvergne, France
[2] Univ Clermont Auvergne, CNRS, EnCoV, IP,UMR 6602, 28 Pl Henri Dunant, F-63001 Clermont Ferrand, France
关键词
Specular highlight; Glare; Lens flare; Motion cue; Context; Retinal mosaicing; Image blending; Slit lamp; SPECULAR REFLECTION; SINGLE IMAGE; CHROMATICITY; COMPONENTS; SEPARATION; MOSAICKING;
D O I
10.1007/s11548-017-1555-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The slit lamp is an essential instrument for eye care. It is used in navigated laser treatment with retina mosaicing to assist diagnosis. Specifics of the imaging setup introduce bothersome illumination artifacts. They not only degrade the quality of the mosaic but may also affect the diagnosis. Existing solutions in SLIM manage to deal with strong glares which corrupt the retinal content entirely while leaving aside the correction of semitransparent specular highlights and lens flare. This introduces ghosting and information loss. We propose an effective technique to detect and correct light reflections of different degrees in SLIM. We rely on the specular-free image concept to obtain glare-free image and use it coupled with a contextually driven probability map to segment the visible part of the retina in every frame before image mosaicing. We then perform the image blending on a subset of all spatially aligned frames. We detect the lens flare and label each pixel as 'flare' or 'non flare' using a probability map. We then invoke an adequate blending method. We also introduce a new quantitative measure for global photometric quality. We tested on a set of video sequences obtained from slit lamp examination sessions of 11 different patients presenting healthy and unhealthy retinas. The segmentation of glare and visible retina was evaluated and compared to state-of-the-art methods. The correction of lens flare and semitransparent highlight with content-aware blending was applied and its performance was evaluated qualitatively and quantitatively. The experiments demonstrated that integrating the proposed method to the mosaicing framework significantly improves the global photometric quality of the mosaics and outperforms existing works in SLIM.
引用
收藏
页码:911 / 920
页数:10
相关论文
共 19 条
[1]   Toward Detection and Localization of Instruments in Minimally Invasive Surgery [J].
Allan, Max ;
Ourselin, Sebastien ;
Thompson, Steve ;
Hawkes, David J. ;
Kelly, John ;
Stoyanov, Danail .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :1050-1058
[2]   Mosaicking and enhancement of slit lamp biomicroscopic fundus images [J].
Asmuth, J ;
Madjarov, B ;
Sajda, P ;
Berger, JW .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (05) :563-565
[3]  
Boykov Y, 2000, LECT NOTES COMPUT SC, V1935, P276
[4]  
Chenxue Xu, 2015, 2015 Visual Communications and Image Processing (VCIP), P1, DOI 10.1109/VCIP.2015.7457903
[5]  
Chhatkuli A, 2014, I S BIOMED IMAGING, P1263, DOI 10.1109/ISBI.2014.6868106
[6]   Specular Reflection Separation using Dark Channel Prior [J].
Kim, Hyeongwoo ;
Jin, Hailin ;
Hadap, Sunil ;
Kweon, Inso .
2013 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2013, :1460-1467
[7]   Automatic glare removal in reflectance imagery of the uterine cervix [J].
Lange, H .
Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 :2183-2192
[8]  
Nussberger A, 2015, IEEE INT CONF ROBOT, P6380, DOI 10.1109/ICRA.2015.7140095
[9]  
Prokopetc K, 2016, INT J COMPUT ASSIS R, V1-10
[10]  
Prokopetc K, 2016, IEEE C COMP VIS PATT, P93