Effects of miniplate anchored Herbst appliance on skeletal, dental and masticatory structures of the craniomandibular apparatus: A finite element study

被引:14
作者
Duggal, Isha [1 ]
Sidhu, Maninder Singh [1 ]
Chawla, Anoop [2 ]
Dabas, Ashish [1 ]
Dhimole, Vivek Kumar [2 ]
机构
[1] SGT Univ, Fac Dent Sci, Dept Orthodont & Dentofacial Orthopaed, Gurugram 122505, Haryana, India
[2] Indian Inst Technol, Dept Mech Engn, New Delhi 110016, India
关键词
Skeletal anchorage; Fixed functional appliance; Herbst appliance; Mandibular protraction; Finite element analysis; Stress pattern; Convergence test; Virtual model; Muscle element modelling; Discal ligament; FIXED FUNCTIONAL APPLIANCE; FATIGUE RESISTANT DEVICE; TEMPOROMANDIBULAR-JOINT; MANDIBULAR PROTRACTION; STRESS-DISTRIBUTION; FORSUS; MINISCREWS; MODEL; SYSTEM;
D O I
10.1016/j.ortho.2021.04.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective > To analyze the stress distribution in the hard and soft tissue structures of craniomandibular complex during mandibular advancement with miniplate anchored rigid fixed functional appliance (FFA) using Finite Element Analysis (FEA). Material and methods > The virtual model consisting of all the maxillofacial bones (up to calvaria), the mandible and temporomandibular joint (TMJ) was generated using the volumetric data from pre-treatment CBCT-scan of a growing patient. The masticatory muscles, other soft tissues, Herbst appliance and plate geometry were modelled mathematically. Force vectors simulating muscle contraction at rest and advanced mandibular positions, with protraction force of 8 N were applied. The final model was imported into ANSYS for analysis after assigning material properties. Results > The maximum von Mises stress of 11.69 MPa and 11.96 MPa magnitude was observed in the region of pterygoid plates and at the bone-miniplate interface respectively, with the mandibular advancement of 7 mm. Stress patterns were also noted at the condylar neck. The stress values observed in the medial and lateral pterygoid muscles were of 10.42 MPa and 4.16 MPa magnitude, respectively. Stress was noted in the bucco-cervical region of the upper posterior teeth, but negligible change was seen on the lower anterior teeth and periodontal ligament. Conclusion > Miniplate Anchored Herbst Appliance brought about Class II skeletal correction in growing children as it was accompanied by minimal changes in the inclination of the lower incisors. Soft tissue structures like pterygoid muscles and discal ligaments exhibited increased stress whereas masseter muscle displayed reduction in stresses.
引用
收藏
页码:301 / 309
页数:9
相关论文
共 44 条
[1]   Treatment effects of the Forsus Fatigue Resistant Device used with miniscrew anchorage [J].
Aslan, Belma I. ;
Kucukkaraca, Ebru ;
Turkoz, Cagri ;
Dincer, Mufide .
ANGLE ORTHODONTIST, 2014, 84 (01) :76-87
[2]   Is there any enhanced treatment effect on class II growing patients when Forsus Fatigue Resistant Device is reinforced by either miniplates or miniscrews? A systematic review and meta-analysis [J].
Bakdach, Wesam Mhd Mounir ;
Hadad, Rania .
INTERNATIONAL ORTHODONTICS, 2021, 19 (01) :15-24
[3]   Development and Validation of a Three-Dimensional Finite Element Model of the Face [J].
Barbarino, G. G. ;
Jabareen, M. ;
Trzewik, J. ;
Nkengne, A. ;
Stamatas, G. ;
Mazza, E. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04)
[4]   FUNCTIONAL APPLIANCES - A REVIEW [J].
BISHARA, SE ;
ZIAJA, RR .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1989, 95 (03) :250-258
[5]   Treatment effects of skeletally anchored Forsus FRD EZ and Herbst appliances: A retrospective clinical study [J].
Celikoglu, Mevlut ;
Buyuk, Suleyman Kutalmis ;
Ekizer, Abdullah ;
Unal, Tuba .
ANGLE ORTHODONTIST, 2016, 86 (02) :306-314
[6]   Evaluation of stress changes in the mandible with a fixed functional appliance: A finite element study [J].
Chaudhry, Anshul ;
Sidhu, Maninder S. ;
Chaudhary, Girish ;
Grover, Seema ;
Chaudhry, Nimisha ;
Kaushik, Ashutosh .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 147 (02) :226-234
[7]  
de Almeida MR, 2005, ANGLE ORTHOD, V75, P540
[8]   Three-dimensional effects of the mini-implant-anchored Forsus Fatigue Resistant Device: A randomized controlled trial [J].
Elkordy, Sherif A. ;
Abouelezz, Amr M. ;
Fayed, Mona M. Salah ;
Attia, Khaled H. ;
Ishaq, Ramy Abdul Rahman ;
Mostafa, Yehya A. .
ANGLE ORTHODONTIST, 2016, 86 (02) :292-305
[9]   3D assessment of mandibular skeletal effects produced by the Herbst appliance [J].
Fan, Yi ;
Schneider, Paul ;
Matthews, Harold ;
Roberts, Wilbur Eugene ;
Xu, Tianmin ;
Wei, Robert ;
Claes, Peter ;
Clement, John ;
Kilpatrick, Nicky ;
Penington, Anthony .
BMC ORAL HEALTH, 2020, 20 (01)
[10]   Influence of conventional and skeletal anchorage system supported fixed functional appliance on maxillo-mandibular complex and temporomandibular joint: A preliminary comparative cone beam computed tomography study [J].
Gandedkar, Narayan H. ;
Shrikantaiah, Shashwath ;
Patil, Anand K. ;
Baseer, Mohammed Abdul ;
Chng, Chai Kiat ;
Ganeshkar, Sanjay V. ;
Kambalyal, Prabhuraj .
INTERNATIONAL ORTHODONTICS, 2019, 17 (02) :267-279