The influences of iron characteristics, operating conditions and solution chemistry on contaminants removal by zero-valent iron: A review

被引:394
|
作者
Sun, Yuankui [1 ,2 ]
Li, Jinxiang [3 ]
Huang, Tinglin [1 ,2 ]
Guan, Xiaohong [3 ]
机构
[1] Xian Univ Architecture & Technol, Minist Educ, Key Lab Northwest Water Resources Environm & Ecol, Xian 710055, Peoples R China
[2] Xian Univ Architecture & Technol, Shaanxi Key Lab Environm Engn, Xian 710055, Peoples R China
[3] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resources Reuse, Shanghai 200092, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Oxide films; Impurity; pH; Dissolved oxygen; Anions; Natural organic matter; WEAK MAGNETIC-FIELD; PERMEABLE REACTIVE BARRIERS; LONG-TERM PERFORMANCE; GROUNDWATER TREATMENT PROCESSES; NATURAL ORGANIC-MATTER; ZEROVALENT IRON; GRANULAR IRON; NITRATE REDUCTION; HUMIC-ACID; IN-SITU;
D O I
10.1016/j.watres.2016.05.031
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For successful application of a zero-valent iron (ZVI) system, of particular interest is the performance of ZVI under various conditions. The current review comprehensively summarizes the potential effects of the major influencing factors, such as iron intrinsic characteristics (e.g., surface area, iron impurities and oxide films), operating conditions (e.g., pH, dissolved oxygen, iron dosage, iron pretreatment, mixing conditions and temperature) and solution chemistry (e.g., anions, cations and natural organic matter) on the performance of ZVI reported in literature. It was demonstrated that all of the factors could exert significant effects on the ZVI performance toward contaminants removal, negatively or positively. Depending on the removal mechanisms of the respective contaminants and other environmental conditions, an individual variable may exhibit different effects. On the other hand, many of these influences have not been well understood or cannot be individually isolated in experimental or natural systems. Thus, more research is required in order to elucidate the exact roles and mechanisms of each factor in affecting the performance of ZVI. Furthermore, based on these understandings, future research may attempt to establish some feasible strategies to minimize the deteriorating effects and utilize the positive effects so as to improve the performance of ZVI. (c) 2016 Elsevier Ltd.
引用
收藏
页码:277 / 295
页数:19
相关论文
共 50 条
  • [31] Mechanisms for removal of p-nitrophenol from aqueous solution using zero-valent iron
    Nakatsuji, Yusuke
    Salehi, Zeinab
    Kawase, Yoshinori
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2015, 152 : 183 - 191
  • [32] Mechanisms of phosphate removal by Micron-Scale Zero-Valent iron
    Zhao, Ying
    Li, Qingxu
    Shi, Qiantao
    Xi, Beidou
    Zhang, Xinyi
    Jian, Zhiqiang
    Zhou, Gaoting
    Meng, Xiaoguang
    Mao, Xuhui
    Kang, Dejun
    Gong, Bin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 319
  • [33] Removal of critical metals from waste water by zero-valent iron
    Vollprecht, Daniel
    Krois, Lisa-Marie
    Sedlazeck, Klaus Philipp
    Mueller, Peter
    Mischitz, Robert
    Olbrich, Tobias
    Pomberger, Roland
    JOURNAL OF CLEANER PRODUCTION, 2019, 208 : 1409 - 1420
  • [34] Effect of Humic Acid on the Nitrate Removal by Strong Base Anion Exchanger Supported Nanoscale Zero-valent Iron Composite
    Wang, Luyao
    Zhou, Hongguang
    Liu, Jie
    Chen, Jie
    Wei, Shiqiang
    Jiang, Zhenmao
    WATER AIR AND SOIL POLLUTION, 2018, 229 (11)
  • [35] Applications of nanoscale zero-valent iron and its composites to the removal of antibiotics: a review
    Zhou, Yuzhou
    Wang, Ting
    Zhi, Dan
    Guo, Binglin
    Zhou, Yaoyu
    Nie, Jing
    Huang, Anqi
    Yang, Yuan
    Huang, Hongli
    Luo, Lin
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (19) : 12171 - 12188
  • [36] Weak magnetic field accelerates chromate removal by zero-valent iron
    Feng, Pian
    Guan, Xiaohong
    Sun, Yuankui
    Choi, Wonyong
    Qin, Hejie
    Wang, Jianmin
    Qiao, Junlian
    Li, Lina
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2015, 31 : 175 - 183
  • [37] Perchlorate Removal Using a Minimized Dosage of Electrodeposited Zero-Valent Iron
    Wang, Chuan
    Liu, Tianfu
    Bu, Fang
    Liu, Hong
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2015, 141 (03)
  • [38] Enhanced chromium(VI) removal by zero-valent iron in the presence of anions and a weak magnetic field: Batch and column tests
    Sun, Yuankui
    Song, Yadan
    Qiao, Junlian
    Pan, Bingcai
    Zhang, Weiming
    Guan, Xiaohong
    CHEMICAL ENGINEERING JOURNAL, 2018, 354 : 445 - 453
  • [39] Use of Nanoscale Zero-Valent Iron (NZVI) Particles for Chemical Denitrification under Different Operating Conditions
    Siciliano, Alessio
    METALS, 2015, 5 (03): : 1507 - 1519
  • [40] The roles of pyrite for enhancing reductive removal of nitrobenzene by zero-valent iron
    Lu, Ying
    Li, Jianfa
    Li, Yimin
    Liang, Liping
    Dong, Huaping
    Chen, Kun
    Yao, Chunxia
    Li, Zhanfeng
    Li, Jinxiang
    Guan, Xiaohong
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2019, 242 : 9 - 18