Carbamazepine interference with an immune assay for tricyclic antidepressants in plasma

被引:22
作者
Chattergoon, DS [1 ]
Verjee, Z [1 ]
Anderson, M [1 ]
Johnson, D [1 ]
McGuigan, MA [1 ]
Koren, G [1 ]
Ito, S [1 ]
机构
[1] Univ Toronto, Hosp Sick Children, Div Clin Pharmacol & Toxicol, Toronto, ON M5G 1X8, Canada
来源
JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY | 1998年 / 36卷 / 1-2期
关键词
D O I
10.3109/15563659809162597
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Background: Drug toxicological screening is commonly used res a diagnostic tool in patients with suspected toxic ingestion. False positive results due to cross-reactive compounds in drug assays may lead to misdiagnosis and mismanagement, especially when child abuse is suspected. Case Report: Two of our patients with history of ingestion of carbamazepine were tested positive on screening with the tricyclic antidepressant immunoassay. The immunoassay's known cross-reactivity for carbamazepine is reportedly as low as 0.3%. Plasma samples of our patients were initially considered positive for tricyclic antidepressants because the cross-reaction of carbamazepine gave tricyclic antidepressant concentrations as imipramine equivalent sufficiently above the assay cut-off point (20 ng/mL). Later, confirmatory urine testing of both patients using high-performance liquid chromatography was negative for tricyclic antidepressants, Conclusion: This interference has significant clinical implications, and can be avoided on mine testing using a specific chromatographic assay such as high-performance liquid chromatography.
引用
收藏
页码:109 / 113
页数:5
相关论文
共 11 条