Development of multiplex HRM-based loop-mediated isothermal amplification method for specific and sensitive detection of Treponema pallidum

被引:4
|
作者
Priya, Krishnamoorthy [1 ]
Rathinasabapathi, Pasupathi [1 ]
Arunraj, Rex [1 ]
Sugapriya, Dhanasekaran [2 ]
Ramya, Mohandass [1 ]
机构
[1] SRM Inst Sci & Technol, Coll Engn & Technol, Dept Genet Engn, Mol Genet Lab, Chennai 603203, Tamil Nadu, India
[2] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Dept Med Lab Pathol, Riyadh 11451, Saudi Arabia
关键词
Treponema pallidum; Serological methods; LAMP; polA; tprL; Multiplex HRM-LAMP; PCR; SYPHILIS; DIAGNOSIS; SPECIMENS; ULCERS; DNA;
D O I
10.1007/s00203-022-02973-z
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Syphilis is a sexually transmitted disease caused by the spirochaete bacterium Treponema pallidum. This study has developed a multiplex High-Resolution Melt-curve Loop-mediated isothermal amplification (multiplex HRM-LAMP) assay targeting the marker genes polA and tprL to detect T. pallidum. The multiplex HRM-LAMP assay conditions were optimized at 65 degrees C for 45 min. Real-time melt-curve analysis of multiplex HRM-LAMP shows two melt-curve peaks corresponding to polA and tprL with a Tm value of 80 +/- 0.5 degrees C and 87 +/- 0.5 degrees C, respectively. The detection limit of multiplex HRM-LAMP was found to be 6.4 x 10(-4) ng/mu L (3.79 copies/mu L) of T. pallidum. The specificity was evaluated using seven different bacterial species, and the developed method was 100% specific in detecting T. pallidum. A total of 64 blood samples of T. pallidum suspected cases were used to validate the assay method. The clinical validation showed that the assay was 96.43% sensitive and 100% specific in detecting syphilis. Thus, the developed method was more rapid and sensitive than other available methods and provides a multigene-based diagnostic approach to detect T. pallidum.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development of multiplex HRM-based loop-mediated isothermal amplification method for specific and sensitive detection of Treponema pallidum
    Krishnamoorthy Priya
    Pasupathi Rathinasabapathi
    Rex Arunraj
    Dhanasekaran Sugapriya
    Mohandass Ramya
    Archives of Microbiology, 2022, 204
  • [2] Multiplex Mediator Displacement Loop-Mediated Isothermal Amplification for Detection of Treponema pallidum and Haemophilus ducreyi
    Becherer, Lisa
    Knauf, Sascha
    Marks, Michael
    Lueert, Simone
    Frischmann, Sieghard
    Borst, Nadine
    von Stetten, Felix
    Bieb, Sibauk
    Adu-Sarkodie, Yaw
    Asiedu, Kingsley
    Mitja, Oriol
    Bakheit, Mohammed
    EMERGING INFECTIOUS DISEASES, 2020, 26 (02) : 282 - 288
  • [3] Multiplex Loop-Mediated Isothermal Amplification Coupled Lateral Flow Assay for Point-of-Care Detection of Syphilis
    Priya, Krishnamoorthy
    Saranya, Elangovan
    Kapoor, Ashish
    Ramya, Mohandass
    INDIAN JOURNAL OF MICROBIOLOGY, 2024, 64 (03) : 1246 - 1256
  • [4] Development and Evaluation of a Loop-Mediated Isothermal Amplification Assay for the Detection of Treponema pallidum DNA in the Peripheral Blood of Secondary Syphilis Patients
    Xiao, Yongjian
    Xie, Yafeng
    Xu, Man
    Liu, Shuangquan
    Jiang, Chuanhao
    Zhao, Feijun
    Zeng, Tiebing
    Liu, Zhuoran
    Yu, Jian
    Wu, Yimou
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2017, 97 (06) : 1673 - 1678
  • [5] Loop-Mediated Isothermal Amplification Assay Using Gold Nanoparticles for Detecting Treponema pallidum subspp. pallidum
    Phurijaruyangkun, Saranthum
    Tangjitrungrot, Pongbun
    Jaratsing, Pornpun
    Augkarawaritsawong, Suphitcha
    Pongparit, Sawanya
    Veeramano, Rungnapa
    Tanomnuch, Kularb
    Areekit, Supatra
    Chansiri, Kosum
    Santiwatanakul, Somchai
    DIAGNOSTICS, 2024, 14 (20)
  • [6] Development of a loop-mediated isothermal amplification method for the rapid detection of Pythium ultimum
    Shen, Danyu
    Li, Qingling
    Yu, Jia
    Zhao, Yuanyuan
    Zhu, Ye
    Xu, Heng
    Dou, Daolong
    AUSTRALASIAN PLANT PATHOLOGY, 2017, 46 (06) : 571 - 576
  • [7] Development of an electrochemical method for Ochratoxin A detection based on aptamer and loop-mediated isothermal amplification
    Xie, Shunbi
    Chai, Yaqin
    Yuan, Yali
    Bai, Lijuan
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 324 - 329
  • [8] Detection of Pathogen-Specific Antibodies by Loop-Mediated Isothermal Amplification
    Burbulis, Ian E.
    Yamaguchi, Kumiko
    Nikolskaia, Olga V.
    Prigge, Sean T.
    Magez, Stefan
    Bisser, Sylvie
    Reller, Megan E.
    Grab, Dennis J.
    CLINICAL AND VACCINE IMMUNOLOGY, 2015, 22 (04) : 374 - 380
  • [9] Development of a loop-mediated isothermal amplification assay for sensitive and rapid detection of Mycoplasma bovis
    Bai, ZhiDi
    Shi, Lei
    Hu, Changmin
    Chen, Xi
    Qi, Jingjing
    Ba, Xiaoliang
    Peng, Qingjie
    Chen, Yingyu
    Chen, Huanchun
    Guo, Aizhen
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (57): : 12333 - 12338
  • [10] Development of a loop-mediated isothermal amplification assay for detection of Trichomonas vaginalis
    Reyes, John Carlo B.
    Solon, Juan Antonio A.
    Rivera, Windell L.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 79 (03) : 337 - 341