Misregistration artifacts in image-derived arterial input function in non-echo-planar imaging-based dynamic contrast-enhanced MRI

被引:1
作者
Kuribayashi, Hideto [1 ]
Worthington, Philip L. [1 ]
Bradley, Daniel P. [1 ]
Checkley, David R. [1 ]
Tessier, Jean J. [1 ]
Waterton, John C. [1 ]
机构
[1] AstraZeneca, Macclesfield, Cheshire, England
关键词
arterial input function; dynamic contrast-enhanced magnetic resonance imaging; misregistration artifact; phase shift; semikeyhole; sliding-window reconstruction;
D O I
10.1002/jmri.20924
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To characterize misregistration artifact in arterial input function (AIF) pixels in dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using a two-dimensional non-echo-planar imaging (EPI)-based gradient-recalled echo (GRE) sequence. Materials and Methods: Dynamic gadopentetate-enhanced MRI was acquired in the rat using a semikeyhole acquisition scheme. The AIF was obtained from abdominal aorta pixels. Different sliding-window reconstruction techniques were applied to determine which lines in a series of the semikeyhole acquisition were associated with the misregistration artifacts. Results: The misregistration along the phase-encoding direction arose when k-space lines were acquired during the rise-time of the aortic gadolinium concentration. The maximum blood concentration of gadolinium estimated from the phase shift calculation agreed with that estimated from dosage. Conclusion: AIF misregistration results from a phase shift due to increasing gadolinium concentration in the aorta, and may need to be considered in small animal DCE-MRI studies with a high rate of rise in the AIF in high-field MR applications.
引用
收藏
页码:1248 / 1255
页数:8
相关论文
共 32 条
  • [1] BAMMER R, 2004, P 12 ANN M ISMRM KYO
  • [2] Dynamic contrast-enhanced MRI of vascular changes induced by the VEGF-signalling inhibitor ZD4190 in human tumour xenografts
    Checkley, D
    Tessier, JJL
    Wedge, SR
    Dukes, M
    Kendrew, J
    Curry, B
    Middleton, B
    Waterton, JC
    [J]. MAGNETIC RESONANCE IMAGING, 2003, 21 (05) : 475 - 482
  • [3] CHU SCK, 1990, MAGN RESON MED, V13, P239, DOI 10.1002/mrm.1910130207
  • [4] THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI
    CONSTABLE, RT
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) : 9 - 24
  • [5] MR IMAGING OF CEREBRAL PERFUSION BY PHASE-ANGLE RECONSTRUCTION OF BOLUS PARAMAGNETIC-INDUCED FREQUENCY-SHIFTS
    CONTURO, TE
    BARKER, PB
    MATHEWS, VP
    MONSEIN, LH
    BRYAN, RN
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 27 (02) : 375 - 390
  • [6] Applications of sliding window reconstruction with cartesian sampling for dynamic contrast enhanced MRI
    d'Arcy, JA
    Collins, DJ
    Rowland, IJ
    Padhani, AR
    Leach, MO
    [J]. NMR IN BIOMEDICINE, 2002, 15 (02) : 174 - 183
  • [7] Expanding the use of magnetic resonance in the assessment of tumor response to therapy: Workshop report
    Evelhoch, J
    Garwood, N
    Vigneron, D
    Knopp, N
    Sullivan, D
    Menkens, A
    Clarke, L
    Liu, GY
    [J]. CANCER RESEARCH, 2005, 65 (16) : 7041 - 7044
  • [8] Improving the temporal resolution of functional MR imaging using keyhole techniques
    Gao, JH
    Xiong, JH
    Lai, S
    Haacke, EM
    Woldorff, MG
    Li, JQ
    Fox, PT
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (06) : 854 - 860
  • [9] Haacke EM, 1999, MAGNETIC RESONANCE I
  • [10] Temporal sampling requirements for the tracer kinetics modeling of breast disease
    Henderson, E
    Rutt, BK
    Lee, TY
    [J]. MAGNETIC RESONANCE IMAGING, 1998, 16 (09) : 1057 - 1073