A miniature cylindrical differential mobility analyzer for sub-3 nm particle sizing

被引:55
作者
Cai, Runlong [1 ]
Chen, Da-Ren [1 ,2 ]
Hao, Jiming [1 ]
Jiang, Jingkun [1 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100084, Peoples R China
[2] Virginia Commonwealth Univ, Dept Mech & Nucl Engn, Med Coll Virginia Campus, Richmond, VA 23284 USA
基金
美国国家科学基金会;
关键词
Cylindrical differential mobility analyzer (DMA); Sub-3 nm particles; Transfer function; New particle formation; Soot particle; HIGH-RESOLUTION; SIZE DISTRIBUTIONS; VIENNA DMA; FLOW; SPECTROMETER; PM2.5; IONS;
D O I
10.1016/j.jaerosci.2017.01.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Effective particle sizing is one of the limitations in measuring sub-3 nm aerosol. In this study we developed a miniature cylindrical differential mobility analyzer (mini-cyDMA) for sub-3 rim particle sizing. The construction of the miniature cylindrical DMA, stemmed from the costeffective DMA (cDMA) developed by Mei et al. (2011), enables it to be operated at higher sheath flowrate than the cDMA. To keep the sheath flow laminar in the DMA classification region for the flowrate up to 30 1 per minute (1pm) for better matching the flowrate required by the aerosol detector while having a good sizing resolution, the DMA components such as the inlet for sheath flow, nylon screen for flow laminarization, and the chambers for polydisperse aerosol flow inlet and excess flow exit were re-designed in the mini-cyDMA. Transfer function of the mini-cyDMA was evaluated using tetra-alkyl ammonium cations with electrical mobility diameters of 1.16 nm, 1.47 nm and 1.78 nm, respectively. A data inversion routine based on an empirical diffusive transfer function was used to obtain the transfer function of the mini-cyDMA. When classifying L47 nm particles at the aerosol-to-sheath flow ratio of 2.5/25 1pm, the penetration efficiency and the sizing resolution of the mini-cyDMA are 0.21 and 5.7, respectively. The mini-cyDMA was deployed to characterize newly-formed atmospheric particles and flame-generated nascent soot particles.
引用
收藏
页码:111 / 119
页数:9
相关论文
共 33 条
  • [1] RE-EVALUATION OF MILLIKAN OIL DROP DATA FOR THE MOTION OF SMALL PARTICLES IN AIR
    ALLEN, MD
    RAABE, OG
    [J]. JOURNAL OF AEROSOL SCIENCE, 1982, 13 (06) : 537 - 547
  • [2] Tandem DMA Generation of Strictly Monomobile 1-3.5 nm Particle Standards
    Attoui, M.
    Paragano, M.
    Cuevas, J.
    de la Mora, J. Fernandez
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2013, 47 (05) : 499 - 511
  • [3] Bezantakos S., 2015, AEROSOL SCI TECHNOLO, V49
  • [4] Radial Differential Mobility Analyzer for One Nanometer Particle Classification
    Brunelli, N. A.
    Flagan, R. C.
    Giapis, K. P.
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2009, 43 (01) : 53 - 59
  • [5] Inhalable Microorganisms in Beijing's PM2.5 and PM10 Pollutants during a Severe Smog Event
    Cao, Chen
    Jiang, Wenjun
    Wang, Buying
    Fang, Jianhuo
    Lang, Jidong
    Tian, Geng
    Jiang, Jingkun
    Zhu, Ting F.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2014, 48 (03) : 1499 - 1507
  • [6] Design and evaluation of a nanometer aerosol differential mobility analyzer (Nano-DMA)
    Chen, DR
    Pui, DYH
    Hummes, D
    Fissan, H
    Quant, FR
    Sem, GJ
    [J]. JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) : 497 - 509
  • [7] Cheng Y, 2011, AEROSOL MEASUREMENT, VThird
  • [8] High resolution size analysis of nanoparticles and ions: Running a Vienna DMA of near optimal length at Reynolds numbers up to 5000
    de Juan, L
    de la Mora, JF
    [J]. JOURNAL OF AEROSOL SCIENCE, 1998, 29 (5-6) : 617 - 626
  • [9] Hand-held differential mobility analyzers of high resolution for 1-30 nm particles: Design and fabrication considerations
    de la Mora, Juan Fernandez
    Kozlowski, Jerzy
    [J]. JOURNAL OF AEROSOL SCIENCE, 2013, 57 : 45 - 53
  • [10] On differential mobility analyzer resolution
    Flagan, RC
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 1999, 30 (06) : 556 - 570