Spiral CT vs incremental CT: Is spiral CT superior in imaging of the brain?

被引:28
作者
Bahner, ML
Reith, W
Zuna, I
Engenhart-Cabillic, R
van Kaick, G
机构
[1] German Canc Res Ctr, Dept Radiol, D-69120 Heidelberg, Germany
[2] Univ Heidelberg, Dept Neuroradiol, D-69120 Heidelberg, Germany
[3] Univ Marburg, Dept Radiotherapy, D-35033 Marburg, Germany
关键词
brain; CT; image quality; spiral CT; comparative studies;
D O I
10.1007/s003300050403
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to evaluate image quality of spiral CT of the brain as compared with incremental CT using identical scanning parameters. Incremental or spiral cranial CT was performed on 46 consecutive, randomized patients with non-traumatic disease of the brain on a Siemens (Erlangen, Germany) Somatom Plus 4. Evaluation was done in a randomized blinded way by two experienced radiologists. Different anatomical structures, image noise, and artifacts were scaled 1 (bad) to 4 (very good). Statistical analysis was done using the F-test of variance for partial sums of squares as well as Student's t-test. Incremental CT was superior to spiral CT for evaluation of the internal capsule, supratentorial artifacts, gray/white matter differentiation, and image noise. No statistically significant differences were seen for evaluation of the pens, infratentorial artifacts, and eye muscles. With identical scanning parameters incremental CT is superior to spiral CT in the assessment of small, complex structures in a low-contrast setting. No differences are seen for larger structures or small structures in a medium-contrast range. Artifacts localized close to the skull in spiral CT can easily mimic hemorrhage in traumatized patients. Spiral CT should therefore only be used for CT angiography and if 3D reconstructions are needed.
引用
收藏
页码:416 / 420
页数:5
相关论文
共 12 条
  • [1] Cerebral CT venography
    Casey, SO
    Alberico, RA
    Patel, M
    Jimenez, JM
    Ozsvath, RR
    Maguire, WM
    Taylor, ML
    [J]. RADIOLOGY, 1996, 198 (01) : 163 - 170
  • [2] GORZER H, 1994, J COMPUT ASSIST TOMO, V18, P839, DOI 10.1097/00004728-199409000-00031
  • [3] SPIRAL(HELICAL) CT
    HEIKEN, JP
    BRINK, JA
    VANNIER, MW
    [J]. RADIOLOGY, 1993, 189 (03) : 647 - 656
  • [4] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [5] PHYSICAL PERFORMANCE-CHARACTERISTICS OF SPIRAL CT SCANNING
    KALENDER, WA
    POLACIN, A
    [J]. MEDICAL PHYSICS, 1991, 18 (05) : 910 - 915
  • [6] 3-DIMENSIONAL SPIRAL CT FOR NEUROSURGICAL PLANNING
    KLEIN, HM
    BERTALANFFY, H
    MAYFRANK, L
    THRON, A
    GUNTHER, RW
    GILSBACH, JM
    [J]. NEURORADIOLOGY, 1994, 36 (06) : 435 - 439
  • [7] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [8] NEURORADIOLOGICAL APPLICATIONS OF SPIRAL CT
    SCHWARTZ, RB
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 1994, 15 (02) : 139 - 147
  • [9] VONKUMMER R, 1994, AM J NEURORADIOL, V15, P9
  • [10] Detectability of cerebral hemisphere ischaemic infarcts by CT within 6 h of stroke
    vonKummer, R
    Nolte, PN
    Schnittger, H
    Thron, A
    Ringelstein, EB
    [J]. NEURORADIOLOGY, 1996, 38 (01) : 31 - 33