Measurements of cavitation dose, echogenicity, and temperature during ultrasound ablation

被引:0
作者
Mast, T. Douglas [1 ]
Salgaonkar, Vasant A. [1 ]
Karunakaran, Chandrapriya [1 ]
Besse, John A. [1 ]
Datta, Saurabh [1 ]
Holland, Christy K. [1 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45267 USA
来源
6TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND | 2007年 / 911卷
关键词
intense ultrasound; ablation; therapy monitoring; passive cavitation detection;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Ultrasound ablation experiments were performed, with simultaneous measurements of acoustic emissions, tissue echogenicity, and tissue temperature, on fresh, degassed bovine liver. The tissue was exposed to bursts of unfocused, continuous-wave, 3.10 MHz from a 3 mm-diameter, 32-element array, which performed B-scan imaging with the same piezoelectric elements during quiescent periods. Exposures employed pulse lengths of 0.9-3.3 s with pressure amplitudes of 0.8-1.4 MPa and duty cycles of 97-99% for exposure times of 6-20 min, sufficient to achieve significant thermal coagulation in all cases. RF echo traces from the array, time-domain signals received by a 1 MHz, unfocused passive cavitation detector, and tissue temperature detected by a needle thermocouple were sampled 0.3-1.1 times per second. Tissue echogenicity was quantified, within the region of significant tissue heating, from the amplitude of RF signals received by the array. Cavitation dose was quantified from the spectra of signals measured by the passive cavitation detector, including subharmonic signal components at 1.55 MHz, broadband signal components within the band 0.3-1.1 MHz, and low-frequency components within the band 10-30 kHz. Tissue ablation effects were assessed by quantitative analysis of digitally imaged, macroscopic tissue sections. Correlation analysis was performed among the averaged and time-dependent acoustic emissions in each band considered, tissue echogenicity, tissue temperature, and ablation rate. Tissue echogenicity correlated significantly with subharmonic and low-frequency emissions as well as tissue temperature, but was uncorrelated with broadband emissions. Ablation rate correlated significantly with broadband and low-frequency emissions, but was uncorrelated with subharmonic emissions.
引用
收藏
页码:335 / +
页数:2
相关论文
共 15 条
  • [1] Mechanisms of lesion formation in high intensity focused ultrasound therapy
    Chen, WS
    Lafon, C
    Matula, TJ
    Vaezy, S
    Crum, LA
    [J]. ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2003, 4 (02): : 41 - 46
  • [2] Interstitial ultrasound heating applicator for MR-guided thermal therapy
    Chopra, R
    Luginbuhl, C
    Weymouth, AJ
    Foster, FS
    Bronskill, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) : 3133 - 3145
  • [3] Ultrasound applicators for interstitial thermal coagulation
    Diederich, CJ
    Nau, WH
    Stauffer, PR
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) : 1218 - 1228
  • [4] Ultrasound-mediated cavitation thresholds of liquid perfluorocarbon droplets in vitro
    Giesecke, T
    Hynynen, K
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (09) : 1359 - 1365
  • [5] Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material
    Holt, RG
    Roy, RA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) : 1399 - 1412
  • [6] Miniaturized ultrasound arrays for interstitial ablation and imaging
    Makin, IRS
    Mast, TD
    Faidi, W
    Runk, MM
    Barthe, PG
    Slayton, MH
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (11) : 1539 - 1550
  • [7] Mast TD, 2005, J ACOUST SOC AM, V118, P3457, DOI [10.1121/1.21108997, 10.1121/1.2108997]
  • [8] Bulk ablation of soft tissue with intense ultrasound: Modeling and experiments
    Mast, TD
    Makin, IRS
    Faidi, W
    Runk, MM
    Barthe, PG
    Slayton, MH
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 118 (04) : 2715 - 2724
  • [9] MAST TD, 2006, UNPUB IEEE T ULTRSON
  • [10] Endoscopic treatment of cholangiocarcinoma and carcinoma of the duodenal papilla by intraductal high-intensity US: results of a pilot study
    Prat, F
    Lafon, C
    de Lima, DM
    Theilliere, Y
    Fritsch, J
    Pelletier, G
    Buffet, C
    Cathignol, D
    [J]. GASTROINTESTINAL ENDOSCOPY, 2002, 56 (06) : 909 - 915