Bone Response to a Pure Titanium Implant Surface Modified by Laser Etching and Microarc Oxidation

被引:0
|
作者
Guo, Zehong [1 ]
Zhou, Lei [1 ]
Rong, Mingdeng [1 ]
Zhu, Andi [1 ]
Geng, Huaou [1 ]
机构
[1] So Med Univ, Affiliated Stomatol Hosp, Guangdong Prov Stomatol Hosp, Guangzhou 510280, Guangdong, Peoples R China
关键词
implant; laser; microarc oxidation; osseointegration; rabbit; titanium; OXIDIZED TITANIUM; IN-VIVO; ARC OXIDATION; ROUGHNESS; COATINGS;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the bone responses to a pure titanium machined implant surface and one that has been modified by laser etching and microarc oxidation. Materials and Methods: Forty-eight threaded implants with a machined surface were manufactured from rods of commercially pure titanium. The control group consisted of 24 implants with a machined surface. The test group consisted of 24 machined-surface implants that were modified by laser etching and treated by microarc oxidation in an electrolyte solution containing Ca2+ and PO43- ions. The implants were analyzed by energy-dispersive x-ray and scanning electron microscopy. Next, the two types of implants were inserted in the tibiae of 12 New Zealand White rabbits; one of the two tibiae received two control implants and the opposite side received two test implants. After 2, 4, and 6 weeks, the rabbits were sacrificed. Prior to sacrifice, all rabbits were injected with fluorescent-labeled achromycin and calcein. Samples were cut and ground for histomorphologic observation, and the mineralization appositional rate and the osseointegration index were measured and analyzed. Results: Proportional spacing craters were found with a diameter of 100 mu m and a depth of 80 to 100 mu m at intervals of 100 mu m around the test surface, and a porous titanium dioxide coating on the surface with pores of 1 to 5 mu m in diameter was also produced. Carbon, oxygen, calcium, and phosphonium were detected by electronic probe. The ratio of calcium to phosphonium was 1.418, and the crystal structure of x-ray diffractive patterns indicated pure anatase phases. Compared with the control samples, the mineralization ratio and the osseointegration index of the bone around the test implants were higher (P = .00). Conclusions: The porous titanium dioxide coating produced by laser etching and microarc oxidation treatment improved the bone response versus that seen around machined titanium implants and enhanced the bone formation rate. It was concluded that the surface chemistry and topography, either separately or together, play an important role in the bone response to implants. INT J ORAL MAXILLOFAC IMPLANTS 2009; 24: 130-136
引用
收藏
页码:130 / 136
页数:7
相关论文
共 50 条
  • [31] Skeletal stem cell and bone implant interactions are enhanced by LASER titanium modification
    Sisti, Karin E.
    de Andres, Maria C.
    Johnston, David
    Almeida-Filho, Edson
    Guastaldi, Antonio C.
    Oreffo, Richard O. C.
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2016, 473 (03) : 719 - 725
  • [32] Invariable current mode microarc oxidation on titanium surface and its energy
    Chen Liuzhu
    Li Wei
    RARE METAL MATERIALS AND ENGINEERING, 2008, 37 (04) : 682 - 685
  • [33] Effects of Titanium Implant Surface Topology on Bone Cell Attachment and Proliferation in vitro
    Levin, Michael
    Spiro, Robert C.
    Jain, Himanshu
    Falk, Matthias M.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2022, 15 : 103 - 119
  • [34] Osteoblast maturation and new bone formation in response to titanium implant surface features are reduced with age
    Olivares-Navarrete, Rene
    Raines, Andrew L.
    Hyzy, Sharon L.
    Park, Jung Hwa
    Hutton, Daphne L.
    Cochran, David L.
    Boyan, Barbara D.
    Schwartz, Zvi
    JOURNAL OF BONE AND MINERAL RESEARCH, 2012, 27 (08) : 1773 - 1783
  • [35] Effect of electrical parameters on characteristics of microarc oxidation coatings of commercially pure titanium in colloid
    Chen Gen-Yu
    Wu Han-Hua
    Li Yue
    Chang Hong
    Tang Yuan-Guang
    ACTA PHYSICA SINICA, 2010, 59 (03) : 1958 - 1963
  • [36] Bone response to the multilayer BMP-2 gene coated porous titanium implant surface
    Jiang, Qiao-Hong
    Liu, Li
    Peel, Sean
    Yang, Guo-Li
    Zhao, Shi-Fang
    He, Fu-Ming
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (08) : 853 - 861
  • [37] Producing High Wettable Surface on Pure Titanium Sheets by Shot Peening for Bone Implant Applications
    Satyanarayana, Chelamalasetti Pavan
    Raju, Lam Ratna
    Dumpala, Ravikumar
    Buradagunta, Ratna Sunil
    BIOINTERFACE RESEARCH IN APPLIED CHEMISTRY, 2022, 12 (05): : 5745 - 5752
  • [38] Influence of different modes of microarc oxidation of titanium on the electrochemical properties and surface morphology of the obtained coatings
    Kasatkin, V. E.
    Kasatkina, I. V.
    Bogdashkina, N. L.
    Gerasimov, M. V.
    Krit, B. L.
    Grigoriev, S. N.
    Suminov, I. V.
    Kozlov, I. A.
    SURFACE ENGINEERING, 2023, 39 (03) : 295 - 306
  • [39] Anticorrosion, antiscale coatings obtained on the surface of titanium alloys by microarc oxidation method and used in seawater
    Gnedenkov, SV
    Gordienko, PS
    Sinebrukhov, SL
    Khrisanphova, OA
    Skorobogatova, TM
    CORROSION, 2000, 56 (01) : 24 - 31
  • [40] The Role of Titanium Implant Surface Modification with Hydroxyapatite Nanoparticles in Progressive Early Bone-Implant Fixation In Vivo
    Lin, Audrey
    Wang, Chiachien Jake
    Kelly, James
    Gubbi, Prabhu
    Nishimura, Ichiro
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 808 - 816