Divalent metal ion-sensitive holographic sensors

被引:33
作者
González, BM [1 ]
Christie, G [1 ]
Davidson, CAB [1 ]
Blyth, J [1 ]
Lowe, CR [1 ]
机构
[1] Univ Cambridge, Inst Biotechnol, Cambridge CB2 1QT, England
基金
英国生物技术与生命科学研究理事会;
关键词
hologram; hydrogel; iminodiacetic acid; smart polymer;
D O I
10.1016/j.aca.2004.03.029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A holographic sensor for real-time detection of divalent metal ions (Ca2+, Mg2+, Ni (2+), Co2+ and Zn2+) has been fabricated by incorporating a chelating monomer into a hydrogel matrix. A methacrylated analogue of iminodiacetic acid (IDA) was prepared and co-polymerised with hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EDMA) as a cross-linker to form polymer films. A silver-based reflection hologram was incorporated into the hydrogel by diffusion followed by holographic recording using a frequency-doubled Nd/YAG laser. Changes in the replay wavelength of the hologram were used to characterise the swelling behaviour of the matrix as a function of its chemical composition and concentration of analyte in the media. The effects of active monomer, cross-linker, pH and ionic strength on the swelling of the matrix and on metal detection sensitivity have been studied. Polymers containing > 10 mol% of chelating monomer and 6 mol% of cross-linker showed significant responses (46.3 nm) within 30 s at an ion concentration of 0-40 nm. The selectivity of the holograms towards the different ions tested was Ni2+ > Zn2+ > CO2+ > Ca2+ > Mg2+. The sensor showed fully reversible responses, permitting real-time monitoring of calcium ion efflux during the germination of Bacillus megaterium spores. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 228
页数:10
相关论文
共 56 条
[1]  
Asher S.A., 1986, SPECTROSCOPY, V1, P26
[2]   SELF-ASSEMBLY MOTIF FOR CREATING SUBMICRON PERIODIC MATERIALS - POLYMERIZED CRYSTALLINE COLLOIDAL ARRAYS [J].
ASHER, SA ;
HOLTZ, J ;
LIU, L ;
WU, ZJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (11) :4997-4998
[3]   Photonic crystal aqueous metal cation sensing materials [J].
Asher, SA ;
Sharma, AC ;
Goponenko, AV ;
Ward, MM .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1676-1683
[4]   Photophysical properties of tris-acetylpyrene derivative of a cryptand in different environments [J].
Bandyopadhyay, P ;
Bharadwaj, PK ;
Roy, MB ;
Dutta, R ;
Ghosh, S .
CHEMICAL PHYSICS, 2000, 255 (2-3) :325-334
[5]   Inductively coupled plasma mass spectrometry [J].
Beauchemin, D .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2873-2893
[6]   Immunoassays for metal ions [J].
Blake, DA ;
Blake, RC ;
Khosraviani, M ;
Pavlov, AR .
ANALYTICA CHIMICA ACTA, 1998, 376 (01) :13-19
[7]   A diffusion method for making silver bromide based holographic recording material [J].
Blyth, J ;
Millington, RB ;
Mayes, AG ;
Lowe, CR .
IMAGING SCIENCE JOURNAL, 1999, 47 (02) :87-91
[8]   Holographic sensor for water in solvents [J].
Blyth, J ;
Millington, RB ;
Mayes, AG ;
Frears, ER ;
Lowe, CR .
ANALYTICAL CHEMISTRY, 1996, 68 (07) :1089-1094
[9]   EQUILIBRIUM SWELLING BEHAVIOR OF PH-SENSITIVE HYDROGELS [J].
BRANNONPEPPAS, L ;
PEPPAS, NA .
CHEMICAL ENGINEERING SCIENCE, 1991, 46 (03) :715-722
[10]   Bacillus megaterium spore germination is influenced by inoculum size [J].
Caipo, ML ;
Duffy, S ;
Zhao, L ;
Schaffner, DW .
JOURNAL OF APPLIED MICROBIOLOGY, 2002, 92 (05) :879-884