The formation of perianchor fluid associated with various suture anchors used in rotator cuff repair ALL-SUTURE, POLYETHERETHERKETONE, AND BIOCOMPOSITE ANCHORS

被引:27
作者
Kim, S. H. [1 ,2 ]
Yang, S. H. [1 ,3 ]
Rhee, S-M [1 ]
Lee, K. J. [1 ,4 ]
Kim, H. S. [1 ]
Oh, J. H. [1 ]
机构
[1] Seoul Natl Univ, Dept Orthopaed Surg, Bundang Hosp, Seongnam, South Korea
[2] Seoul Natl Univ Hosp, Dept Orthopaed Surg, Seoul, South Korea
[3] KS Hosp, Dept Orthopaed Surg, Seongnam, South Korea
[4] Sun Orthopaed Hosp, Dept Orthopaed Surg, Seongnam, South Korea
关键词
SHOULDER; COMPLICATIONS; RADIOLUCENCY; TEARS;
D O I
10.1302/0301-620X.101B12.BJJ-2019-0462.R2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims The aim of this study was to compare the osseous reactions elicited by all-suture, polyetheretherketone (PEEK), and two different biodegradable anchors used during rotator cuff repair. Patients and Methods Transosseous-equivalent rotator cuff repair was performed in 73 patients. The patients were divided into two groups, in both of which two different medial-row anchors were used. In group 1, anchor A comprised 30% beta-tricalcium phosphate (TCP) + 70% fast-absorbing poly lactic-co-glycolic acid copolymer (85% polylactic acid enantiomers + 15% polyglycolic acid) and anchor B comprised all-sutures. In group 2, anchor C comprised 23% micro beta-TCP + 77% polylactic acid enantiomers and anchor D comprised PEEK polymer. There were 37 patients in group 1 and 36 patients in group 2. The presence and severity of fluid collection around anchors and healing of the rotator cuff were assessed using MRI scans, approximately one year postoperatively. The severity of the collection was graded as 0 (no perianchor fluid signal), 1 (minimal perianchor fluid), 2 (local collection of fluid), 3 (fluid collection around the whole length of the anchor but of a diameter less than twice the anchor diameter), or 4 (fluid collection around the whole length of the anchor and of a diameter greater than twice the anchor diameter). Results A perianchor fluid signal was seen in three patients (8.1%) with anchor A, four (10.8%) with anchor B, 15 (41.7%) with anchor C, and 15 (41.7%) with anchor D. The severity of the collection around anchor was grade 2:1:0:0 for anchor A, grade 2:2:0:0 for anchor B, grade 12:2:0:1 for anchor C, and grade 11:3:0:1 for anchor D (grade 1:2:3:4, respectively). The prevalence and severity of fluid formation was not significantly different between anchors A and B, and anchors C and D. However, on intergroup analysis, there were significant differences for the prevalence and severity of fluid formation between anchors in group 1 and group 2. The prevalence of failure to heal was not significant in group 1 (seven, 18.9%) or group 2 (nine, 25.0%). There was no relationship between the presence of perianchor fluid and each type of anchor, and the integrity of the rotator cuff repair, in either group. Conclusion Despite the nonabsorbable nature of all-suture and PEEK anchors, all-suture anchors produced less osseous reaction after rotator cuff repair. In deciding which kind of anchor to use, consideration should be given not only to the strength of the initial fixation, but also to the postoperative biological reaction.
引用
收藏
页码:1506 / 1511
页数:6
相关论文
共 22 条
[1]   Triple labrum tears repaired with the JuggerKnot™ soft anchor: Technique and results [J].
Agrawal, Vivek ;
Pietrzak, William S. .
INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2015, 9 (03) :81-89
[2]   Osteolysis and arthropathy of the shoulder after use of bioabsorbable knotless suture anchors - A report of four cases [J].
Athwal, George S. ;
Shridharani, Shyam M. ;
O'Driscoll, Shawn W. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (08) :1840-1845
[4]  
Barber FA, 2015, SPORTS MED ARTHROSC, V23, P149, DOI 10.1097/JSA.0000000000000076
[5]   RESULTS OF A 2ND ATTEMPT AT SURGICAL REPAIR OF A FAILED INITIAL ROTATOR-CUFF REPAIR [J].
DEORIO, JK ;
COFIELD, RH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (04) :563-567
[6]   Complications of Bioabsorbable Suture Anchors in the Shoulder [J].
Dhawan, Aman ;
Ghodadra, Neil ;
Karas, Vasili ;
Salata, Michael J. ;
Cole, Brian J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2012, 40 (06) :1424-1430
[7]   Pullout strength of all suture anchors in the repair of rotator cuff tears: a biomechanical study [J].
Galland, Alexandre ;
Airaudi, Stephane ;
Gravier, Renaud ;
Le Cann, Sophie ;
Chabrand, Patrick ;
Argenson, Jean-Noel .
INTERNATIONAL ORTHOPAEDICS, 2013, 37 (10) :2017-2023
[8]   Biomechanical comparison of traditional anchors to all-suture anchors in a double-row rotator cuff repair cadaver model [J].
Goschka, Andrew M. ;
Hafer, Jason S. ;
Reynolds, Kirk A. ;
Aberle, Nicholas S., II ;
Baldini, Todd H. ;
Hawkins, Monica J. ;
McCarty, Eric C. .
CLINICAL BIOMECHANICS, 2015, 30 (08) :808-813
[9]   Arthroscopic double-row repair of the rotator cuff: a comparison of bio-absorbable and non-resorbable anchors regarding osseous reaction [J].
Haneveld, Hendrik ;
Hug, Konstantin ;
Diederichs, Gerd ;
Scheibel, Markus ;
Gerhardt, Christian .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (07) :1647-1654
[10]   Osseous integration of poly-(L-co-D/L-Lactide) 70/30 and titanium suture anchors:: An experimental study in sheep cancellous bone [J].
Kääb, MJ ;
Rahn, BA ;
Weiler, A ;
Curtis, R ;
Perren, SM ;
Schneider, E .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 :37-42