The field of three-dimensional multi-modal X-ray nanoimaging relies not only on high-brilliance X-rays but also on high-precision mechanics and position metrology. Currently available state-of-the-art linear and rotary drives can provide 3D position accuracy within tens to hundreds of nm, which is often insufficient for high resolution imaging with nanofocused X-ray beams. Motion errors are especially troublesome in the case of rotation drives and their correction is more complicated and relies on the metrology grade reference objects. Here we present a method which allows the characterisation and correction of the radial and angular errors of the rotary drives without the need for a highly accurate metrology object. The method is based on multi-probe error separation using fiber-laser interferometry and uses a standard cylindrical sample holder as a reference. The obtained runout and shape measurements are then used to perform the position corrections using additional drives. We demonstrate the results of the characterization for a piezo-driven small rotation stage. The error separation allowed us to measure the axis runout to be approximately +/-1.25 mu m, and with active runout compensation this could be reduced down to +/-42 nm. Published by AIP Publishing.
引用
收藏
页数:6
相关论文
共 50 条
[31]   Local Motion Detection, Characterization, and Quantification for X-ray CT [J].
Hsieh, Jiang .
MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
[32]   THREE DIMENSIONAL CHARACTERIZATION OF SOIL MACROPOROSITY BY X-RAY MICROTOMOGRAPHY [J].
Passoni, Sabrina ;
Pires, Luiz Fernando ;
Heck, Richard ;
Rosa, Jadir Aparecido .
REVISTA BRASILEIRA DE CIENCIA DO SOLO, 2015, 39 (02) :448-457
[33]   Characterization of failure in soils using X-ray CT scanner [J].
Otani, J ;
Obara, Y ;
Mukunoki, T .
DEFORMATION AND PROGRESSIVE FAILURE IN GEOMECHANICS - IS-NAGOYA'97, 1997, :311-314
[34]   Characterization of Prebake Anodes by Micro X-ray Computed Tomography [J].
Rorvik, Stein ;
Lossius, Lorentz Petter .
LIGHT METALS 2017, 2017, :1237-1245
[35]   Synchrotron X-ray nanotomography and three-dimensional nanoscale imaging analysis of pore structure-function in nanoporous polymeric membranes [J].
Lee, Se-Hee ;
Chang, Won-Seok ;
Han, Sung-Mi ;
Kim, Duck-Hyun ;
Kim, Jong-Ki .
JOURNAL OF MEMBRANE SCIENCE, 2017, 535 :28-34
[36]   X-Ray Tomography as a Diagnostic Method of X-Ray Refractive Optics [J].
Narikovich, A. S. ;
Ershov, P. A. ;
Leitsin, V. N. ;
Savin, V. V. ;
Snigirev, A. A. .
INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2017, 60 (03) :390-393
[37]   X-ray computed tomography using projection X-ray microscope [J].
Yoshimura, F ;
Miyata, C ;
Kuzuryu, C ;
Hori, A ;
Obi, T ;
Ohyama, N .
DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 :166-171
[38]   Development of x-ray laminography under an x-ray microscopic condition [J].
Hoshino, Masato ;
Uesugi, Kentaro ;
Takeuchi, Akihisa ;
Suzuki, Yoshio ;
Yagi, Naoto .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (07)
[39]   A microfocus X-ray tube based on a microstructured X-ray target [J].
Ihsan, Aamir ;
Heo, Sung Hwan ;
Cho, Sung Oh .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (21-22) :3566-3573
[40]   Computer-assisted quantification of periaxial bone rotation from X-ray CT [J].
Tsao, J ;
Chiodo, CP ;
Williamson, DS ;
Wilson, MG ;
Kikinis, R .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :615-620