High-resolution, energy-dispersive microcalorimeter spectrometer for X-ray microanalysis

被引:196
|
作者
Wollman, DA
Irwin, KD
Hilton, GC
Dulcie, LL
Newbury, DE
Martinis, JM
机构
[1] Natl Inst Stand & Technol, Boulder, CO 80303 USA
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
来源
JOURNAL OF MICROSCOPY-OXFORD | 1997年 / 188卷
关键词
count rate; EDS; energy-dispersive detector; high energy resolution; microcalorimeter spectrometer; microcalorimeter; particle identification; polycapillary X-ray optics; solid angle; TES microcalorimeter; WDS; X-ray microanalysis; X-ray microcalorimeter; X-ray spectroscopy;
D O I
10.1046/j.1365-2818.1997.2670824.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
We have developed a prototype ii-ray microcalorimeter spectrometer with high energy resolution for use in ii-ray microanalysis. The microcalorimeter spectrometer system consists of a superconducting transition-edge sensor X-ray microcalorimeter cooled to an operating temperature near 100 mK by a compact adiabatic demagnetization refrigerator, a superconducting quantum interference device current amplifier followed by pulse-shaping amplifiers and pileup rejection circuitry, and a multichannel analyser with computer interface for the real-time acquisition of X-ray spectra. With the spectrometer mounted on a scanning electron microscope, we have achieved an instrument response energy resolution of better than 10 eV full width at half-maximum (FWHM) over a broad energy range at real-time output count rates up to 150 s(-1). Careful analysis of digitized X-ray pulses yields an instrument-response energy resolution of 7.2 +/- 0.4 eV FWHM at 5.89 keV for Mn K alpha(1,2) X-rays from a radioactive Fe-55 source, the best reported energy resolution for any energy-dispersive detector.
引用
收藏
页码:196 / 223
页数:28
相关论文
共 50 条
  • [21] The High-Resolution X-ray Microcalorimeter Spectrometer System for the SXS on ASTRO-H
    Mitsuda, Kazuhisa
    Kelley, Richard L.
    Boyce, Kevin R.
    Brown, Gregory V.
    Costantini, Elisa
    DiPirro, Michael J.
    Ezoe, Yuichiro
    Fujimoto, Ryuichi
    Gendreau, Keith C.
    den Herder, Jan-Willem
    Hoshino, Akio
    Ishisaki, Yoshitaka
    Kilbourne, Caroline A.
    Kitamoto, Shunji
    McCammon, Dan
    Murakami, Masahide
    Murakami, Hiroshi
    Ogawa, Mina
    Ohashi, Takaya
    Okamoto, Atsushi
    Paltani, Stephane
    Pohl, Martin
    Porter, F. Scott
    Sato, Yoichi
    Shinozaki, Keisuke
    Shirron, Peter J.
    Sneiderman, Gary A.
    Sugita, Hiroyuki
    Szymkowiak, Andrew
    Takei, Yoh
    Tamagawa, Toru
    Tashiro, Makoto
    Terada, Yukikatsu
    Tsujimoto, Masahiro
    de Vries, Cor
    Yamaguchi, Hiroya
    Yamasaki, Noriko Y.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [22] A Method to Test the Performance of an Energy-Dispersive X-Ray Spectrometer (EDS)
    Hodoroaba, Vasile-Dan
    Procop, Mathias
    MICROSCOPY AND MICROANALYSIS, 2014, 20 (05) : 1556 - 1564
  • [23] A SPECTROMETER FOR X-RAY ENERGY-DISPERSIVE DIFFRACTION USING SYNCHROTRON RADIATION
    OLSEN, JS
    BURAS, B
    GERWARD, L
    STEENSTRUP, S
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (10): : 1154 - 1158
  • [24] A simple method to improve the quantification accuracy of energy-dispersive X-ray microanalysis
    Walther, T.
    EMAG: ELECTRON MICROSCOPY AND ANALYSIS GROUP CONFERENCE 2007, 2008, 126
  • [26] ENERGY-DISPERSIVE X-RAY ANALYSIS - COMPARISON BETWEEN X-RAY MICROANALYSIS AND X-RAY-FLUORESCENCE ANALYSIS
    LINNEMANN, B
    REIMER, L
    MIKROSKOPIE, 1978, 34 (5-6) : 145 - 146
  • [27] SIMULTANEOUS USE OF ENERGY-DISPERSIVE AND WAVELENGTH-DISPERSIVE SPECTROMETERS IN X-RAY-MICROANALYSIS - DEVELOPMENT OF AN ADJUSTABLE APERTURE IN FRONT OF THE ENERGY-DISPERSIVE SPECTROMETER
    VANAMELSVOORT, JMM
    SMITS, HTJ
    STADHOUDERS, AM
    MICRON, 1982, 13 (02) : 229 - 234
  • [28] REDUCTION OF BACKGROUND DUE TO BACKSCATTERED ELECTRONS IN ENERGY-DISPERSIVE X-RAY MICROANALYSIS
    HALL, TA
    JOURNAL OF MICROSCOPY-OXFORD, 1977, 110 (JUL): : 103 - 106
  • [29] ENERGY-DISPERSIVE X-RAY SPECTROSCOPY
    HURLEY, JP
    DAGRAGNA.VL
    MATHIESEN, JM
    RESEARCH-DEVELOPMENT, 1970, 21 (12): : 14 - +
  • [30] Energy-dispersive x-ray fluorescence spectrometer with capillary optics for the chemical analysis of atmospheric aerosols with high time resolution
    Holynska, B
    Ptasinski, J
    Maenhaut, W
    Annegarn, HJ
    JOURNAL OF AEROSOL SCIENCE, 1997, 28 (08) : 1455 - 1463