Angiographic Analysis of Vascular Integrity After Percutaneous Closure Using Prostar XL Device During Transcatheter Aortic Valve Implantation

被引:5
作者
Lareyre, Fabien [1 ,2 ]
Raffort, Juliette [2 ]
Dommerc, Carine [1 ]
Benhammamia, Mohamed [1 ]
Bourlon, Francois [1 ]
Habib, Yacoub [1 ]
Mialhe, Claude [1 ]
机构
[1] Cardiothorac Ctr Monaco, 11 Bis Ave Ostende, MC-98000 Monaco, Monaco
[2] Univ Cote Azur, CNRS, INSERM, IRCAN, Nice, France
关键词
Prostar XL; vascular complications; vascular closure device; transfemoral access angiography; transcatheter aortic valve implantation; ACCESS; COMPLICATIONS; DEFINITIONS;
D O I
10.1177/1538574417705285
中图分类号
R61 [外科手术学];
学科分类号
摘要
Introduction: Percutaneous closure devices are commonly used to achieve hemostasis during endovascular procedures including transcatheter aortic valve implantation (TAVI). The aim of our study was to investigate the quality of the percutaneous femoral arterial closure by Prostar XL device using a systematic peroperative angiographic control at the end of TAVI procedure. Materials and Methods: Two hundred seventeen consecutive patients (mean age: 84 [6.5]; 112 women and 105 men) undergoing TAVI with percutaneous transfemoral access were prospectively registered in our center. Preoperative computed tomography scan was performed, and mean femoral vessel diameter was 7.9 (0.9) mm. At the end of TAVI intervention, the hemostasis was systematically achieved using the percutaneous closure device Prostar XL, without selection of patients based on anatomical criteria. An angiography with front and oblique views was performed to evaluate the quality and the safety of the closure device. Success of the percutaneous closure was defined as the absence of hemorrhage and the restitution of the arterial anatomy. Complications related to the percutaneous closure were classified as stenosis, dissection at the puncture site, suture failure, misplacement, or persistent bleeding. Results: Twenty-three (10.6%) patients had complications related to arterial percutaneous closure14 (60.8%) stenosis, 6 (26.1%) persistent bleeding, and 1 (4.3%) dissection. These lesions were accessible to endovascular treatment via a crossover procedure. One (4.3%) suture failure and 1 (4.3%) misplacement of the device, with a puncture site created above the femoral arch, were reported. The patient developed a retroperitoneal hematoma postoperatively and required transfusion of 2 units of red blood cells associated with a cutdown to remove hematoma and to repair the common femoral artery. Conclusion: Angiography after arterial percutaneous closure using Prostar XL device during TAVI allows detection and endovascular treatment of vascular complications and is associated with low rate of conversion to open surgery.
引用
收藏
页码:282 / 287
页数:6
相关论文
共 17 条
  • [1] Percutaneous Interventions in Aortic Disease
    Aranson, Nathan J.
    Watkins, Michael T.
    [J]. CIRCULATION, 2015, 131 (14) : 1291 - 1299
  • [2] Comparison of suture-based vascular closure devices in transfemoral transcatheter aortic valve implantation
    Barbanti, Marco
    Capranzano, Piera
    Ohno, Yohei
    Gulino, Simona
    Sgroi, Carmelo
    Imme, Sebastiano
    Tamburino, Claudia
    Cannata, Stefano
    Patane, Martina
    Di Stefano, Daniele
    Todaro, Denise
    Di Simone, Emanuela
    Deste, Wanda
    Gargiulo, Giuseppe
    Capodanno, Davide
    Grasso, Carmelo
    Tamburino, Corrado
    [J]. EUROINTERVENTION, 2015, 11 (06) : 690 - 697
  • [3] Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation
    Barbash, Israel M.
    Barbanti, Marco
    Webb, John
    De Nicolas, Javier Molina-Martin
    Abramowitz, Yigal
    Latib, Azeem
    Nguyen, Caroline
    Deuschl, Florian
    Segev, Amit
    Sideris, Konstantinos
    Buccheri, Sergio
    Simonato, Matheus
    Della Rosa, Francesco
    Tamburino, Corrado
    Jilaihawi, Hasan
    Miyazaki, Tadashi
    Himbert, Dominique
    Schofer, Niklas
    Guetta, Victor
    Bleiziffer, Sabine
    Tchetche, Didier
    Imme, Sebastiano
    Makkar, Raj R.
    Vahanian, Alec
    Treede, Hendrik
    Lange, Ruediger
    Colombo, Antonio
    Dvir, Danny
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (47) : 3370 - 3379
  • [4] Large calibre arterial access device closure for percutaneous aortic valve interventions: Use of the prostar system in 118 cases
    Cockburn, James
    de Belder, Adam
    Brooks, Michael
    Hutchinson, Nevil
    Hill, Andrew
    Trivedi, Uday
    Hildick-Smith, David
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 79 (01) : 143 - 149
  • [5] Vascular closure devices - The second devices
    Dauerman, Harold L.
    Applegate, Robert J.
    Cohen, David J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (17) : 1617 - 1626
  • [6] Aorto-iliac angiography as a screening tool in selecting patients for transfemoral aortic valve implantation with the Edwards SAPIEN bioprosthesis
    Eltchaninoff, Helene
    Kerkeni, Mehdi
    Zajarias, Alan
    Tron, Christophe
    Godin, Matthieu
    Giron, Carlos Sanchez
    Baala, Brahim
    Cribier, Alain
    [J]. EUROINTERVENTION, 2009, 5 (04) : 438 - 442
  • [7] Vascular Complications After Transcatheter Aortic Valve Replacement
    Genereux, Philippe
    Webb, John G.
    Svensson, Lars G.
    Kodali, Susheel K.
    Satler, Lowell F.
    Fearon, William F.
    Davidson, Charles J.
    Eisenhauer, Andrew C.
    Makkar, Raj R.
    Bergman, Geoffrey W.
    Babaliaros, Vasilis
    Bavaria, Joseph E.
    Velazquez, Omaida C.
    Williams, Mathew R.
    Hueter, Irene
    Xu, Ke
    Leon, Martin B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (12) : 1043 - 1052
  • [8] A Systematic Literature Review of the Efficacy and Safety of the Prostar XL Device for the Closure of Large Femoral Arterial Access Sites in Patients Undergoing Percutaneous Endovascular Aortic Procedures
    Haulon, S.
    Khodja, R. Hassen
    Proudfoot, C. W.
    Samuels, E.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 41 (02) : 201 - 213
  • [9] True Percutaneous Approach for Transfemoral Aortic Valve Implantation Using the Prostar XL Device Impact of Learning Curve on Vascular Complications
    Hayashida, Kentaro
    Lefevre, Thierry
    Chevalier, Bernard
    Hovasse, Thomas
    Romano, Mauro
    Garot, Philippe
    Mylotte, Darren
    Uribe, Jhonathan
    Farge, Arnaud
    Donzeau-Gouge, Patrick
    Bouvier, Erik
    Cormier, Bertrand
    Morice, Marie-Claude
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (02) : 207 - 214
  • [10] Percutaneous Versus Surgical Management of Lower Extremity Peripheral Artery Disease
    Kakkar, Amit M.
    Abbott, J. Dawn
    [J]. CURRENT ATHEROSCLEROSIS REPORTS, 2015, 17 (02)