Short-column liquid chromatography with hydride generation atomic fluorescence detection for the speciation of arsenic

被引:128
作者
Le, XC [1 ]
Ma, MS [1 ]
机构
[1] Univ Alberta, Fac Med, Dept Publ Hlth Sci, Environm Hlth Sci Program, Edmonton, AB T6G 2G3, Canada
关键词
D O I
10.1021/ac971247q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Increasing concerns over human exposure to arsenic and more stringent environmental regulations require rapid determination of trace levels of individual arsenic species, which presents an analytical challenge. We describe a method that is capable of speciating nanogram-per-milliliter levels of arsenite (As(III)), arsenate (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) within 3 min. Speciation of two common inorganic species in drinking water, As(III) and As(V), is complete in 1.5 min. The method is based on a combination of fast high-performance liquid chromatography (HPLC) separation of arsenic species on 3-cm HPLC guard columns and the sensitive detection of arsenic hydride by atomic fluorescence spectrometry. Detection limits for the four arsenic species in urine samples are 0.4-0.8 ng/mL. This simple method allows for the direct speciation of arsenic present in natural water samples and in human mine samples from the general population, with no need of any sample pretreatment. Our results from the determination of arsenic species in urine and water standard reference materials are in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of metabolism of arsenosugars following the consumption of arsenosugar-containing mussels by human volunteers. Speciation of arsenic in urine samples collected from four volunteers after the ingestion of mussels reveals significant increases of DMAA concentration, resulting from the metabolism of arsenosugars. These results suggest that the commonly used biomarkers for assessing human exposure to inorganic arsenic, which are based on the determination of urinary arsenite, arsenate, MMAA, and DMAA, are not reliable when arsenosugar-containing seafood is ingested.
引用
收藏
页码:1926 / 1933
页数:8
相关论文
共 58 条
[11]  
CHEN CJ, 1985, CANCER RES, V45, P5895
[12]   HIGH-SPEED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES AND PROTEINS [J].
CHEN, H ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY A, 1995, 705 (01) :3-20
[13]   Arsenic speciation by liquid chromatography coupled with ionspray tandem mass spectrometry [J].
Corr, JJ ;
Larsen, EH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (12) :1215-1224
[14]  
Crecelius E, 1997, ENVIRON HEALTH PERSP, V105, P650
[15]   CHANGES IN CHEMICAL SPECIATION OF ARSENIC FOLLOWING INGESTION BY MAN [J].
CRECELIUS, EA .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1977, 19 (AUG) :147-150
[16]   ARSENIC SPECIATION IN THE ENVIRONMENT [J].
CULLEN, WR ;
REIMER, KJ .
CHEMICAL REVIEWS, 1989, 89 (04) :713-764
[17]   DETERMINATION OF THE GROWTH PROMOTER, 4-HYDROXY-3-NITROPHENYL-ARSONIC ACID IN CHICKEN TISSUE BY COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
DEAN, JR ;
EBDON, L ;
FOULKES, ME ;
CREWS, HM ;
MASSEY, RC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (05) :615-618
[18]   ARSENIC SPECIATION BY MICELLAR LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION [J].
DING, H ;
WANG, JS ;
DORSEY, JG ;
CARUSO, JA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 694 (02) :425-431
[19]  
Dixon HBF, 1997, ADV INORG CHEM, V44, P191
[20]  
Edmonds JS, 1997, APPL ORGANOMET CHEM, V11, P281, DOI 10.1002/(SICI)1099-0739(199704)11:4<281::AID-AOC581>3.0.CO