Rapid analysis of selected beer volatiles by atmospheric pressure chemical ionisation-mass spectrometry

被引:16
作者
Ashraf, Nadim [1 ]
Linforth, Robert S. T. [1 ]
Bealin-Kelly, Francis
Smart, Katherine [1 ]
Taylor, Andrew J. [1 ]
机构
[1] Univ Nottingham, Sch Biosci, Samworth Flavour Lab, Loughborough LE12 5RD, Leics, England
关键词
APCI-MS; GC-MS; Fermentation; Headspace; Regression model; DIRECT APCI-MS; ORGANIC-COMPOUNDS; ISOBARIC COMPOUNDS; HEADSPACE ANALYSIS; ETHANOLIC SYSTEMS; RELEASE; DISCRIMINATION; MIXTURES;
D O I
10.1016/j.ijms.2010.05.007
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
For rapid determination of some key aroma compounds in fermented beer, headspace was analysed by atmospheric pressure chemical ionisation-mass spectrometry (APCI-MS) and the ion intensities used to predict beer aroma content. To achieve this aim, potential interference from ethanol during ionisation was overcome by using ethanol as the charge transfer reagent ion and the cone voltage was varied to induce fragmentation of the compounds and provide more information to build a robust correlation between headspace analysis and concentration in the beer itself. Ten solutions containing different ethanol concentrations (0.5-5 mL/100 mL), and different concentrations of the key aroma compounds, were analysed by APCI-MS at cone voltages between 12 and 21 V. Linear regression models were created for each compound to correlate the ion intensities measured by APCI-MS at the different cone voltages with the in-solution concentration of the compounds (average R-2=0.95). Of the 14 compounds studied, six could be quantified unequivocally, six compounds were quantified as pairs of isobaric compounds and two could not be reliably analysed. To test the linear regression model equations, the headspace above samples of fermenting wort or commercial beer and cider products were analysed by APCI-MS and the predicted concentrations of twelve aroma compounds in the samples were compared with the actual values measured by extraction and GC-MS analysis: correlation coefficients ranged between 0.753 and 0.979. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:47 / 53
页数:7
相关论文
共 24 条
[1]   Headspace analysis of volatile organic compounds from ethanolic systems by direct APCI-MS [J].
Aznar, M ;
Tsachaki, M ;
Linforth, RST ;
Ferreira, V ;
Taylor, AJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 239 (01) :17-25
[2]  
BAJIC S, 1993, INT LAB, V13, P4
[3]  
Biasioli F, 2007, PTR MS FOOD SCI TECH, P111
[4]   Aldehyde and ketone discrimination and quantification using two-stage proton transfer reaction mass spectrometry [J].
Blake, Robert S. ;
Patel, Milan ;
Monks, Paul S. ;
Ellis, Andrew M. ;
Inomata, Satoshi ;
Tanimoto, Hiroshi .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2008, 278 (01) :15-19
[5]  
Boulton C., 2001, BREWING YEAST FERMEN
[6]   Analysis of volatile flavour compounds by Proton Transfer Reaction-Mass Spectrometry: fragmentation patterns and discrimination between isobaric and isomeric compounds [J].
Buhr, K ;
van Ruth, S ;
Delahunty, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 221 (01) :1-7
[7]   ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY - CORONA DISCHARGE ION-SOURCE FOR USE IN LIQUID CHROMATOGRAPH MASS SPECTROMETER-COMPUTER ANALYTICAL SYSTEM [J].
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN ;
HAEGELE, KD ;
HORNING, EC .
ANALYTICAL CHEMISTRY, 1975, 47 (14) :2369-2373
[8]  
DANIEL RD, 1993, RAPID COMMUN MASS SP, V7, P462
[9]   A hollow cathode proton transfer reaction time of flight mass spectrometer [J].
Ennis, CJ ;
Reynolds, JC ;
Keely, BJ ;
Carpenter, LJ .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 247 (1-3) :72-80
[10]   Quantitatively resolving mixtures of isobaric compounds using chemical ionization mass spectrometry by modulating the reactant ion composition [J].
Fortner, E. C. ;
Knighton, W. B. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (16) :2597-2601