Experimental thermal performance analysis of finned tube-phase change material based double pass solar air heater

被引:149
作者
Sajawal, Muhammad [1 ]
Rehman, Tauseef-ur [1 ]
Ali, Hafiz Muhammad [2 ]
Sajjad, Uzair [3 ]
Raza, Ali [4 ]
Bhatti, Muhammad Sheheryar [5 ]
机构
[1] Univ Engn & Technol, Mech Engn Dept, Taxila 47050, Pakistan
[2] KFUPM, Mech Engn Dept, Dhahran 31261, Saudi Arabia
[3] Natl Chiao Tung Univ, Mech Engn Dept, Thermal Management & Energy Efficiency Lab, Hsinchu, Taiwan
[4] HITEC Univ, Mech Engn Dept, Taxila 47050, Pakistan
[5] Pakistan Navy Engn Coll, Mech Engn Dept, Karachi 75350, Pakistan
关键词
Phase change material; Finned tube; Energy storage; Solar air heater; Thermal management; ENERGY STORAGE; GRAPHENE NANOPLATELETS; IMPROVEMENT; COLLECTOR; DESIGN; FLAT; FOAM; PCM;
D O I
10.1016/j.csite.2019.100543
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present experimental study is performed to investigate the thermal performances of double pass solar air heater comprising of phase change materials (PCM) contained in metallic finned tubes to have increased energy storage and heat transfer rate. Experimental results were also helpful in the evaluation of the charging and the discharging characteristics of the PCMs. The air heater is studied for three different configurations. In the first configuration, is no PCM used. In the second configuration, RT44HC having higher melting point filled in semi-circular finned tubes (SFT) on the upper pass of double pass solar air heater (DPSAH) as a thermal storage medium (TSM) is used. While the third configuration is a combination of the second configuration and RT18HC having lower melting point, filled in circular finned tubes (FT) as TSM placed in the lower pass to enhance the thermal storage capacity of solar air heater (SAH). The heater's thermal performance is evaluated for all configurations separately. It was revealed that the third configuration containing RT44HC and RT18HC in upper and lower passes respectively is the best among others for optimum heater performance.
引用
收藏
页数:12
相关论文
共 44 条
[1]   Performance improvement of double-pass solar air heater - A state of art of review [J].
Alam, Tabish ;
Kim, Man-Hoe .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 79 :779-793
[2]   Thermal performance of LHSU for electronics under steady and transient operations modes [J].
Ali, Hafiz Muhammad ;
Arshad, Adeel ;
Janjua, Muhammad Mansoor ;
Baig, Wajahat ;
Sajjad, Uzair .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 :1223-1232
[3]   AN EXPERIMENTAL INVESTIGATION OF PERFORMANCE OF A DOUBLE PASS SOLAR AIR HEATER WITH THERMAL STORAGE MEDIUM [J].
Ali, Hafiz Muhammad ;
Bhatti, Arslan Iqbal ;
Ali, Muzaffar .
THERMAL SCIENCE, 2015, 19 (05) :1699-1708
[4]  
AlKamil MT, 1997, ENERG CONVERS MANAGE, V38, P1451, DOI 10.1016/S0196-8904(96)00050-7
[5]   A mathematical model of thermal performance of a solar air heater with slats [J].
Ammari, HD .
RENEWABLE ENERGY, 2003, 28 (10) :1597-1615
[6]   A highly efficient solution of off-sunshine solar air heating using two packed beds of latent storage energy [J].
Arfaoui, Nessim ;
Bouadila, Salwa ;
Guizani, Amenallah .
SOLAR ENERGY, 2017, 155 :1243-1253
[7]   THE DEPENDENCE OF SOLAR AIR HEATER PERFORMANCE UPON TILT AND ORIENTATION [J].
BADESCU, V .
ENERGY CONVERSION AND MANAGEMENT, 1990, 30 (02) :179-185
[8]   Effect of employing a new biological nanofluid containing functionalized graphene nanoplatelets on thermal and hydraulic characteristics of a spiral heat exchanger [J].
Bahiraei, Mehdi ;
Salmi, Hamid Kiani ;
Safaei, Mohammad Reza .
ENERGY CONVERSION AND MANAGEMENT, 2019, 180 :72-82
[9]  
Bayrak F, 2015, ISI BILIM TEK DERG, V35, P11
[10]   Air-based solar systems for building heating with PCM fluidized bed energy storage [J].
Belmonte, J. F. ;
Izquierdo-Barrientos, M. A. ;
Molina, A. E. ;
Almendros-Ibanez, J. A. .
ENERGY AND BUILDINGS, 2016, 130 :150-165