Neural Implants Without Electronics: A Proof-of-Concept Study on a Human Skin Model

被引:4
作者
Kiele, Patrick [1 ]
Braig, David [2 ,3 ]
Weiss, Jakob [3 ]
Baslan, Yara [1 ]
Pasluosta, Cristian [1 ]
Stieglitz, Thomas [1 ,4 ,5 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn EMTEK, Lab Biomed Microtechnol, D-79110 Freiburg, Germany
[2] Univ Freiburg, Med Ctr, Fac Med, Dept Plast & Hand Surg, D-79106 Freiburg, Germany
[3] Ludwig Maximilians Univ Munchen, Div Hand Plast & Aesthet Surg, Univ Hosp, D-80336 Munich, Germany
[4] Univ Freiburg, Bernstein Ctr Freiburg, D-79098 Freiburg, Germany
[5] Univ Freiburg, BrainLinks BrainTools, D-79110 Freiburg, Germany
来源
IEEE OPEN JOURNAL OF ENGINEERING IN MEDICINE AND BIOLOGY | 2020年 / 1卷
关键词
Capacitive coupling; electrode; neural implant; skin; telemetry; SOMATOSENSORY FEEDBACK; RESTORATION; STIMULATION; INTERFACE; SYSTEM;
D O I
10.1109/OJEMB.2020.2981254
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Chronic neural implants require energy and signal supply. The objective of this work was to evaluate a multichannel transcutaneous coupling approach in an ex vivo split-concept study, which minimizes the invasiveness of such an implant by externalizing the processing electronics. Methods: Herein, the experimental work focused on the transcutaneous energy and signal transmission. The performance was discussed with widely evaluated concepts of neural interfaces in the literature. Results: The performance of the transcutaneous coupling approach increased with higher channel count and higher electrode pitches. Electrical crosstalk among channels was present, but acceptable for the stimulation of peripheral nerves. Conclusions: Transcutaneous coupling with extracorporeal transmitting arrays and subcutaneous counterparts provide a promising alternative to the inductive concept particularly when a fully integration of the system in a prosthetic shaft is intended. The relocation of the electronics can potentially prevent pressure sores, improve accessibility for maintenance and increase lifetime of the implant.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 29 条
[1]   A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve [J].
Boretius, Tim ;
Badia, Jordi ;
Pascual-Font, Aran ;
Schuettler, Martin ;
Navarro, Xavier ;
Yoshida, Ken ;
Stieglitz, Thomas .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :62-69
[2]   High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations [J].
Charkhkar, Hamid ;
Shell, Courtney E. ;
Marasco, Paul D. ;
Pinault, Gilles J. ;
Tyler, Dustin J. ;
Triolo, Ronald J. .
JOURNAL OF NEURAL ENGINEERING, 2018, 15 (05)
[3]  
Clark GA, 2014, IEEE ENG MED BIO, P1977, DOI 10.1109/EMBC.2014.6944001
[4]  
Daly JJ, 2001, J REHABIL RES DEV, V38, P513
[5]   Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves [J].
Davis, T. S. ;
Wark, H. A. C. ;
Hutchinson, D. T. ;
Warren, D. J. ;
O'Neill, K. ;
Scheinblum, T. ;
Clark, G. A. ;
Normann, R. A. ;
Greger, B. .
JOURNAL OF NEURAL ENGINEERING, 2016, 13 (03)
[6]  
Desai VH, 2017, I IEEE EMBS C NEUR E, P203, DOI 10.1109/NER.2017.8008326
[7]   Residual function in peripheral nerve stumps of amputees: Implications for neural control of artificial limbs [J].
Dhillon, GS ;
Lawrence, SM ;
Hutchinson, DT ;
Horch, KW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (04) :605-615
[8]   The dielectric properties of biological tissues .3. Parametric models for the dielectric spectrum of tissues [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2271-2293
[9]   Properties of the Stimulus Router System, a Novel Neural Prosthesis [J].
Gan, Liu Shi ;
Prochazka, Arthur .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (02) :450-459
[10]   THE STRENGTH-DURATION CURVE [J].
GEDDES, LA ;
BOURLAND, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (06) :458-459