Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint

被引:645
作者
Block, Kai Tobias [1 ]
Uecker, Martin [1 ]
Frahm, Jens [1 ]
机构
[1] Biomed NMR Forsch GmbH, Max Planck Inst Biophys Chem, D-37070 Gottingen, Germany
关键词
compressed sensing; inverse problems; iterative reconstruction; projection reconstruction; regridding;
D O I
10.1002/mrm.21236
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The reconstruction of artifact-free images from radially encoded MRI acquisitions poses a difficult task for undersampled data sets, that is for a much lower number of spokes in k-space than data samples per spoke. Here, we developed an iterative reconstruction method for undersampled radial MRI which (i) is based on a nonlinear optimization, (ii) allows for the incorporation of prior knowledge with use of penalty functions, and (iii) deals with data from multiple coils. The procedure arises as a two-step mechanism which first estimates the coil profiles and then renders a final image that complies with the actual observations. Prior knowledge is introduced by penalizing edges in coil profiles and by a total variation constraint for the final image. The latter condition leads to an effective suppression of undersampling (streaking) artifacts and further adds a certain degree of denoising. Apart from simulations, experimental results for a radial spin-echo MRI sequence are presented for phantoms and human brain in vivo at 2.9 T using 24,48, and 96 spokes with 256 data samples. In comparison to conventional reconstructions (regridding) the proposed method yielded visually improved image quality in all cases.
引用
收藏
页码:1086 / 1098
页数:13
相关论文
共 26 条
[1]   Time-resolved contrast-enhanced imaging with isotropic resolution and broad coverage using an undersampled 3D projection trajectory [J].
Barger, AV ;
Block, WF ;
Toropov, Y ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (02) :297-305
[2]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[3]  
Bernstein MA, 2004, HDB MRI PULSE SEQUEN, P616
[4]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[5]  
CHANG TC, 2006, P INT SOC MAG RESON, V14, P696
[6]   A fast and accurate Fourier algorithm for iterative parallel-beam tomography [J].
Delaney, AH ;
Bresler, Y .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (05) :740-753
[7]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[8]   NONLINEAR IMAGE RECOVERY WITH HALF-QUADRATIC REGULARIZATION [J].
GEMAN, D ;
YANG, CD .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (07) :932-946
[9]   CONSISTENT PROJECTION RECONSTRUCTION (CPR) TECHNIQUES FOR MRI [J].
GLOVER, GH ;
NOLL, DC .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (03) :345-351
[10]   Radial GRASE: Implementation and applications [J].
Gmitro, AF ;
Kono, M ;
Theilmann, RJ ;
Altbach, MI ;
Li, ZQ ;
Trouard, TP .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) :1363-1371