A full Stokes imaging polarimeter based on a consumer CMOS camera

被引:1
|
作者
Pena-Gutierrez, Sara [1 ]
Ballesta, Maria [1 ]
Royo, Santiago [1 ]
机构
[1] Univ Politecn Cataluna, Ctr Desenvolupament Sensors Instrumentacio & Sist, Rambla St Nebridi 10, E-08222 Terrassa, Spain
关键词
Imaging polarimetry; polarization; machine vision;
D O I
10.1117/12.2525706
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Nowadays, taking advantage of polarization allows enhancing the contrast of a detected object and extending the information of the scene compared to conventional intensity imagery, as the information added by polarimetric images is complementary to intensity ones. Using polarization has a wide interest in space exploration, earth remote sensing, machine vision and biomedical diagnosis, and is extending its use to several applications. Here, we present a basic imaging polarimeter which measures the full Stokes vector of the scene based on a division of time structure, based on a consumer CMOS camera. The polarization state of partially or fully polarized light can be represented by means of the Stokes vector, which is the goal of the measurement. However, due to its nature, the components of the Stokes vector cannot be measured directly, as they must be recovered from a set of intensity measurements. In the paper the results show the measured intensity at 632nm and the recovered Stokes data produced by the determined data reduction matrix at six reference polarization states, as well as the theoretical and recovered Stokes parameters from the calibration experiment. The root mean square (RMS) errors are below 10%. Therefore, this system can provide a well-conditioned data reduction matrix for noise immunity and the spectral range can be widened by using white light and a monochrome camera.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Optimization of Polarization-Camera-Based Full Stokes Polarimeter
    Li Haiyu
    Li Chao
    Li Xiaobo
    Wang Hui
    Hu Haofeng
    Liu Tiegen
    ACTA OPTICA SINICA, 2020, 40 (03)
  • [2] Four camera complete Stokes imaging polarimeter
    Pezzaniti, J. Larry
    Chenault, David
    Roche, Mike
    Reinhardt, John
    Pezzaniti, Joseph P.
    Schultz, Howard
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING VIII, 2008, 6972
  • [3] Design and calibration for a Full-Stokes imaging polarimeter
    Montes Gonzalez, Ivan
    Bruce, Neil C.
    UNCONVENTIONAL OPTICAL IMAGING, 2018, 10677
  • [4] Snapshot compressive imaging full-Stokes polarimeter
    Xu, Zhilong
    Meng, Jianwen
    Zhao, Man
    Yang, Ting
    Wu, Dan
    Zhang, Rui
    Xie, Yingge
    Ren, Wenyi
    OPTICS COMMUNICATIONS, 2022, 509
  • [5] Robust full Stokes imaging polarimeter with dynamic calibration
    Shibata, Shuhei
    Hagen, Nathan
    Otani, Yukitoshi
    OPTICS LETTERS, 2019, 44 (04) : 891 - 894
  • [6] Full Stokes polarization imaging camera
    Vedel, M.
    Breugnot, S.
    Lechocinski, N.
    POLARIZATION SCIENCE AND REMOTE SENSING V, 2011, 8160
  • [7] Static hyperspectral imaging polarimeter for full linear Stokes parameters
    Mu, Tingkui
    Zhang, Chunmin
    Jia, Chenling
    Ren, Wenyi
    OPTICS EXPRESS, 2012, 20 (16): : 18194 - 18201
  • [8] A compact full Stokes polarimeter
    Chaturvedi, M.
    Bhandare, R.
    Kumar, S.
    Verma, Y.
    Raja, S.
    OPTIK, 2022, 267
  • [9] A compact full Stokes polarimeter
    Chaturvedi, M.
    Bhandare, R.
    Kumar, S.
    Verma, Y.
    Raja, S.
    Optik, 2022, 267
  • [10] Full-Stokes imaging polarimeter using an array of elliptical polarizer
    Hsu, Wei-Liang
    Myhre, Graham
    Balakrishnan, Kaushik
    Brock, Neal
    Ibn-Elhaj, Mohammed
    Pau, Stanley
    OPTICS EXPRESS, 2014, 22 (03): : 3063 - 3074