Push-out tests on bolted shear connectors in composite cold-formed steel beams

被引:26
作者
Hosseinpour, Mahmoud [1 ]
Zeynalian, Mehran [1 ]
Ataei, Abdoreza [1 ]
Daei, Maryam [1 ]
机构
[1] Univ Isfahan, Dept Civil Engn, Esfahan, Iran
关键词
Cyclic test; Composite floor joists; Cold-formed steel composite beam; Cold-formed steel-concrete composite  connection; BEHAVIOR;
D O I
10.1016/j.tws.2021.107831
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Composite beams comprised of steel sections and concrete slabs, are one of the most widely used beams due to their advantages such as improving stiffness and strength compared to bare steel or reinforced concrete beams. Moreover, another important advantage of such beams is to prevent buckling of steel section by placing it under tension, which is especially important for low-thickness steel sections such as cold-formed steel (CFS) sections. Although the use of CFS sections in combination with concrete slabs can increase the efficiency of such sections, their low thickness makes it difficult to weld traditional studs as shear connectors on their top flanges. The current paper presents an experimental investigation about the behavior of bolted shear connectors in the composite cold-formed steel beams as a suitable alternative to welded shear studs. To do so, three main parameters including thickness of CFS sections, and size and strength of bolts were taken into account. Fifteen full-scale push-out specimens were constructed and tested. The ultimate load, ductility, stiffness and failure mode of all specimens were then assessed; and their results were reported and precisely discussed. Based on the results, depending on the size and strength of bolts, the ultimate load per shear connector for 1 mm thick CFS sections' specimens is found between 6.2 and 8.6 KN, while this value for specimens by 2 mm thick CFS sections, is found between 15.6 and 26.8 KN. Moreover, based on EC4, the ductility of shear connectors was examined; the results indicate that all bolted shear connectors in this study can be assumed ductile and can be used in partial shear connections.
引用
收藏
页数:15
相关论文
共 31 条
[1]   Behavior of pre-cast U-Shaped Composite Beam integrating cold-formed steel with ferro-cement slab [J].
Alhajri, T. M. ;
Tahir, M. M. ;
Azimi, M. ;
Mirza, J. ;
Lawan, M. M. ;
Alenezi, K. K. ;
Ragaee, M. B. .
THIN-WALLED STRUCTURES, 2016, 102 :18-29
[2]  
American Iron and Steel Institute Standard, 2007, N AM SPEC DES COLD F
[3]  
[Anonymous], 2013, INT C COMP CONSTR ST
[4]  
[Anonymous], 11 INT
[5]  
[Anonymous], 2014, STANDARD TEST METHOD, P1
[6]  
[Anonymous], 1996, P 13 INT SPEC C COLD
[7]  
[Anonymous], 2014, 23 AUSTR C MECH STRU
[8]   Cyclic behaviour of bolted shear connectors in steel-concrete composite beams [J].
Ataei, Abdolreza ;
Zeynalian, Mehran ;
Yazdi, Yahya .
ENGINEERING STRUCTURES, 2019, 198
[9]   Experimental study of composite beams having a precast geopolymer concrete slab and deconstructable bolted shear connectors [J].
Ataei, Abdolreza ;
Bradford, Mark A. ;
Liu, Xinpei .
ENGINEERING STRUCTURES, 2016, 114 :1-13
[10]   Behaviour of headed stud shear connectors under low-cycle high amplitude displacements [J].
Bursi, OS ;
Gramola, G .
MATERIALS AND STRUCTURES, 1999, 32 (218) :290-297