Drug Release From Irradiated PLGA and PLLA Multi-Layered Films

被引:45
作者
Loo, Say Chye Joachim [1 ]
Tan, Zhi Ying Serlin [1 ]
Chow, Yi Jun [1 ]
Lin, Siew Ling Ivy [1 ]
机构
[1] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
关键词
controlled release; biodegradable polymers; materials science; polymeric drug delivery systems; water sorption; ELECTRON-BEAM RADIATION; HYDROLYTIC DEGRADATION; POLY(LACTIDE-CO-GLYCOLIDE) PLGA; POLYMERIC NANOPARTICLES; POLY(L-LACTIDE) PLLA; STENT COATINGS; IN-VITRO; DELIVERY; PACLITAXEL; SIROLIMUS;
D O I
10.1002/jps.22079
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Poly(lactide-co-glycolic acid) (PLGA) and poly(L-lactide) (PLLA) films are widely studied for various biomedical applications. Because of their use for drug delivery, achieving controlled release from these biodegradable films has become an area of intense research. The objective of this study is therefore to investigate how PLGA and PLLA films fabricated through an irradiated-multi-layer approach can be a viable technique to achieve controlled drug delivery. In this study, lidocaine base (lido-base) and lidocaine salt (lido-salt) were used as model hydrophobic and hydrophilic drugs, respectively. Results show that multi-layer PLGA underwent pseudo surface degradation, while multi-layer PLLA degraded to a lesser extent over the same study period. Triphasic release was observed for lido-base, whereas lido-salt was released through a biphasic profile, from both polymer systems. The two dominating release phases for both drugs were diffusion and zero-order release, where the latter is characterized by the onset of mass loss. It was shown that PLGA had a shorter diffusion phase and a longer zero-order phase, while the contrary was true for PLLA. This difference was due to the faster degradation for PLGA. In conclusion, the hydrophilic gradient induced from an irradiated-multi-layer film system shows potential for controlled and sustained release of drugs. (C) 2010 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 99:3060-3071, 2010
引用
收藏
页码:3060 / 3071
页数:12
相关论文
共 47 条
[1]   A flexible technology for modified release of drugs: multi layered tablets [J].
Abdul, S ;
Poddar, SS .
JOURNAL OF CONTROLLED RELEASE, 2004, 97 (03) :393-405
[2]   DEVELOPMENT AND CHARACTERIZATION OF TETRACYCLINE-POLY(LACTIDE GLYCOLIDE) FILMS FOR THE TREATMENT OF PERIODONTITIS [J].
AGARWAL, RK ;
ROBINSON, DH ;
MAZE, GI ;
REINHARDT, RA .
JOURNAL OF CONTROLLED RELEASE, 1993, 23 (02) :137-146
[3]   Factors affecting the degradation and drug-release mechanism of poly(lactic acid) and poly[(lactic acid)-co-(glycolic acid)] [J].
Alexis, F .
POLYMER INTERNATIONAL, 2005, 54 (01) :36-46
[4]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[5]  
CHASIN M, 1990, DRUGS PHARM SCI, V45, P43
[6]   A novel drug-eluting stent spray-coated with multi-layers of collagen and sirolimus [J].
Chen, MC ;
Liang, HF ;
Chiu, YL ;
Chang, Y ;
Wei, HJ ;
Sung, HW .
JOURNAL OF CONTROLLED RELEASE, 2005, 108 (01) :178-189
[7]   Controlled degradation of multilayered poly(lactide-co-glycolide) films using electron beam irradiation [J].
Chia, N. K. ;
Venkatraman, S. S. ;
Boey, F. Y. C. ;
Cadart, S. ;
Loo, J. S. C. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (04) :980-987
[8]   MULTILAYERED HYDROPHILIC MATRICES AS CONSTANT RELEASE DEVICES (GEOMATRIX(TM) SYSTEMS) [J].
CONTE, U ;
MAGGI, L ;
COLOMBO, P ;
LAMANNA, A .
JOURNAL OF CONTROLLED RELEASE, 1993, 26 (01) :39-47
[9]   D-α-Tocopheryl polyethylene glycol 1000 succinate (TPGS) modified poly(L-lactide) (PLLA) films for localized delivery of paclitaxel [J].
Dong, Yuancai ;
Zhang, Zhiping ;
Feng, Si-Shen .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2008, 350 (1-2) :166-171
[10]   In-vitro release of fluoropyrimidines from PLGA film implants [J].
Dorta, MJ ;
Oliva, A ;
Munguía, O ;
Llabrés, M ;
Fariña, JB .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2002, 54 (06) :757-763