Domestic wastewater disinfection by combined treatment using multi-soil-layering system and sand filters (MSL-SF): A laboratory pilot study

被引:48
作者
Latrach, Lahbib [1 ,2 ]
Ouazzani, Naaila [1 ,2 ]
Masunaga, Tsugiyuki [3 ]
Hejjaj, Abdessamad [1 ]
Bouhoum, Khadija [2 ]
Mahi, Mustapha [4 ]
Mandi, Laila [1 ,2 ]
机构
[1] Cadi Ayyad Univ, Natl Ctr Res & Study Water & Energy CNEREE, POB 511, Marrakech 40000, Morocco
[2] Fac Sci Semlalia, Lab Hydrobiol Ecotoxicol & Sanitat LHEA, URAC 33, Marrakech, Morocco
[3] Shimane Univ, Fac Life & Environm Sci, Matsue, Shimane 6908504, Japan
[4] Natl Off Elect & Potable Water IEA ONEE, Int Inst Water & Sanitat, Rabat, Morocco
关键词
Fecal indicators; Multi-soil-layering system; Nutrients; Organic matter; Parasites; Sand filter; Wastewater treatment; CONSTRUCTED WETLANDS; NITROGEN REMOVAL; PERFORMANCE; PHOSPHORUS; FILTRATION; MECHANISMS;
D O I
10.1016/j.ecoleng.2016.02.036
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
This study aims to present the removal of bacterial indicators of fecal contamination and parasites in a combined treatment using a multi-soil-layering system with sand filters (MSL-SF). This experiment was carried out in a laboratory scale. The MSL pilot (height 65 cm, width 36 cm, depth 30 cm) was composed of soil mixture layers (SML) and gravel layers that are arranged in a brick-layer like pattern. The soil mixture layers are composed of local sandy soil mixed with sawdust, metal iron and charcoal at the ratio of 70, 10, 10 and 10%, respectively, on a dry weight basis. The applied hydraulic loading rate (HLR) was 200 L m(-2) day(-1). The experimental sand filter included three parallel similar sand columns (inside diameter 12.5 cm, height 120 cm). Each column was filled with 80 cm of fine sand and 10 cm of gravel in the top and the bottom of the filter. Three sand columns HLRs (100, 200 and 400 L m(-2) day(-1)) were compared. The obtained results indicated that the conceptual model based on the combination of the MSL method and sand filter (MSL-SF) showed very high efficiency in organic matter, nutrients, bacteria and the reduction of parasites. The high performances were noted in the low HLR. The main removal percentage of SS, BOD5, COD, TN and TP were respectively 99.73, 97.78, 98.40, 92.93 and 96.21% for the HLR-100. In addition, the Log(10) removal for total coliforms, fecal coliforms and fecal streptococci were 4.46, 4.47 and 4.13 Log unit respectively. MSL-SF is capable of removing 100% of helminthes eggs. The MSL system is an efficient method, especially for organic matter and nutrients (N, P) removal. Sand filters have experimentally been proved to be useful for fecal indicators and the removal of parasites. Good operational stability and high contaminants removal efficiency of the combined systems were observed. Therefore, the combination of the MSL system and sand filter offer a good alternative option for agricultural wastewater reuse. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 32 条
[1]  
AFNOR, 1997, REC NORM FRANC EAU M
[2]  
[Anonymous], 2005, Standard methods for the examination of water and waste- water
[3]   Intermittent filtration of wastewater - removal of fecal coliforms and fecal streptococci [J].
Ausland, G ;
Stevik, TK ;
Hanssen, JF ;
Kohler, JC ;
Jenssen, PD .
WATER RESEARCH, 2002, 36 (14) :3507-3516
[4]  
BAILENGER J., 1962, PHARMACIEN BIOLOGISTE, V3, P249
[5]   Treatment of secondary wastewater effluents by infiltration percolation [J].
Bali, M. ;
Gueddari, M. ;
Boukchina, R. .
DESALINATION, 2010, 258 (1-3) :1-4
[6]  
Bock E., 1989, AUTOTROPHIC BACTERIA, V42, P81
[7]   Removal of fish pathogenic bacteria in biological sand filters [J].
Bomo, AM ;
Husby, A ;
Stevik, TK ;
Hanssen, JF .
WATER RESEARCH, 2003, 37 (11) :2618-2626
[8]  
BOUHOUM K, 1989, ZBL HYG UMWELTMED, V188, P322
[9]   INFILTRATION PERCOLATION IN FRANCE - 10 YEARS EXPERIENCE [J].
BRISSAUD, F ;
LESAVRE, J .
WATER SCIENCE AND TECHNOLOGY, 1993, 28 (10) :73-81
[10]  
Chen X, 2008, WATER ENVIRON J, V4, P255