An investigation into the effects of excipient particle size, blending techniques and processing parameters on the homogeneity and content uniformity of a blend containing low-dose model drug

被引:55
作者
Alyami, Hamad [1 ]
Dahmash, Eman [1 ,3 ]
Bowen, James [2 ]
Mohammed, Afzal R. [1 ]
机构
[1] Aston Univ, Aston Sch Pharm, Birmingham, W Midlands, England
[2] Open Univ, Dept Engn & Innovat, Milton Keynes, Bucks, England
[3] Aston Univ, Aston Particle Technol Ltd, Birmingham, W Midlands, England
关键词
PHARMACEUTICAL POWDERS; DISINTEGRATING TABLETS; SEGREGATION; ADHESION; FLOW;
D O I
10.1371/journal.pone.0178772
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Powder blend homogeneity is a critical attribute in formulation development of low dose and potent active pharmaceutical ingredients (API) yet a complex process with multiple contributing factors. Excipient characteristics play key role in efficient blending process and final product quality. In this work the effect of excipient type and properties, blending technique and processing time on content uniformity was investigated. Powder characteristics for three commonly used excipients (starch, pregelatinised starch and microcrystalline cellulose) were initially explored using laser diffraction particle size analyser, angle of repose for flowability, followed by thorough evaluations of surface topography employing scanning electron microscopy and interferometry. Blend homogeneity was evaluated based on content uniformity analysis of the model API, ergocalciferol, using a validated analytical technique. Flowability of powders were directly related to particle size and shape, while surface topography results revealed the relationship between surface roughness and ability of excipient with high surface roughness to lodge fine API particles within surface groves resulting in superior uniformity of content. Of the two blending techniques, geometric blending confirmed the ability to produce homogeneous blends at low dilution when processed for longer durations, whereas manual ordered blending failed to achieve compendial requirement for content uniformity despite mixing for 32 minutes. Employing the novel dry powder hybrid mixer device, developed at Aston University laboratory, results revealed the superiority of the device and enabled the production of homogenous blend irrespective of excipient type and particle size. Lower dilutions of the API (1% and 0.5% w/w) were examined using non-sieved excipients and the dry powder hybrid mixing device enabled the development of successful blends within compendial requirements and low relative standard deviation.
引用
收藏
页数:19
相关论文
共 42 条
[11]   The influence of carrier roughness on adhesion, content uniformity and the in vitro deposition of terbutaline sulphate from dry powder inhalers [J].
Flament, MP ;
Leterme, P ;
Gayot, A .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 275 (1-2) :201-209
[12]  
Harnby, 2000, Pharm Sci Technol Today, V3, P303, DOI 10.1016/S1461-5347(00)00283-2
[13]   ORDERED MIXING - NEW CONCEPT IN POWDER MIXING PRACTICE [J].
HERSEY, JA .
POWDER TECHNOLOGY, 1975, 11 (01) :41-44
[14]  
Hirani JJ, 2009, TROP J PHARM RES, V8, P161
[15]   PREPARATION OF DRUG-DILUENT HYBRID POWDERS BY DRY PROCESSING [J].
ISHIZAKA, T ;
HONDA, H ;
KIKUCHI, Y ;
ONO, K ;
KATANO, T ;
KOISHI, M .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1989, 41 (06) :361-368
[16]   Improvement of flow and bulk density of pharmaceutical powders using surface modification [J].
Jallo, Laila J. ;
Ghoroi, Chinmay ;
Gurumurthy, Lakxmi ;
Patel, Utsav ;
Dave, Rajesh N. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2012, 423 (02) :213-225
[17]  
Kaye B.H., 1997, Powder mixing
[18]  
Kornchankul W, 2002, PHARMAZIE, V57, P49
[19]  
Kukkar V., 2008, Thai Journal of Pharmaceutical Sciences, V32, P43
[20]  
Leach R. K., 2008, Measurement Good Practice Guide