Programming optimal atrioventricular delay in dual chamber pacing using acceleration: Comparison with a standard echocardiographic procedure

被引:45
作者
Dupuis, JM
Kobeissi, A
Vitali, L
Gaggini, G
Merheb, M
Rouleau, F
Leftheriotis, G
Ritter, P
Victor, J
机构
[1] Univ Hosp Angers, Dept Cardiol, F-49033 Angers 01, France
[2] Sorin Biomed CRM, Saluggia, Italy
[3] InParys, Paris, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
atrioventricular delay; peak endocardial acceleration; pacemaker programming;
D O I
10.1046/j.1460-9592.2003.00018.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Optimization of programmed atrioventricular delay in dual chamber pacing is essential to the hemodynamic efficiency of the heart. Automatic AV delay optimization in an implanted pacemaker is highly desirable. Variations of peak endocardial acceleration (PEA) with AV delay at rest correlate well with echocardiography derived observations, particularly with end-diastolic filling and mitral valve closure timings. This suggests the possibility of devising a procedure for the automatic determination of the optimal AV delay. The aim of this study was to compare a proposed algorithm for optimal AV delay determination with an accepted echocardiographic method. Fifteen patients with high degree AV block received BEST-Living pacing systems, Automatic AV delay scans were performed at rest (60-300 ms in 20-ms steps with 60 beats per step) in DDD at 90 ppm, while simultaneously recording cycle-by-cycle PEA values, which were averaged for each AV delay to obtain a PEA versus AV delay curve. Nonlinear regression analysis based on a Boltzmann sigmoid curve was performed, and the optimal AV delay (OAVD) was chosen as the sigmoid inflection point of the regression curve. The OAVD was also evaluated for each patient using the Bitter echocardiographic method. Good sigmoid fit was obtained in 13 of 15 patients. The mean OAVD obtained by the PEA sigmoid algorithm was 146.9 +/- 32.1 ms, and the corresponding result obtained by echocardiography was 156.4 +/- 34.3 ms (range 31.8-39.7 ms). Correlation analysis yielded r = 0.79, P = 0.0012. In conclusion, OAVD estimates obtained by PEA analysis during automatic AV delay scanning are consistent with those obtained by echocardiography. The proposed algorithm can be used for automatic OAVD determination in an implanted pacemaker pulse generator.
引用
收藏
页码:210 / 213
页数:4
相关论文
共 23 条
[1]   Cardiac resynchronization therapy restores optimal atrioventricular mechanical timing in heart failure patients with ventricular conduction delay [J].
Auricchio, A ;
Ding, J ;
Spinelli, JC ;
Kramer, AP ;
Salo, RW ;
Hoersch, W ;
KenKnight, BH ;
Klein, HU .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (07) :1163-1169
[2]  
CARLETON RA, 1966, CLIN SCI, V30, P151
[3]   SEQUENTIAL ATRIOVENTRICULAR PACING IN HEART BLOCK COMPLICATING ACUTE MYOCARDIAL INFARCTION [J].
CHAMBERL.DA ;
VASSAUX, CE ;
KASTOR, JA ;
DESANCTI.RW ;
SANDERS, CA .
NEW ENGLAND JOURNAL OF MEDICINE, 1970, 282 (11) :577-&
[4]   Dual chamber rate responsive pacing system driven by contractility:: Final assessment after 1-year follow-up [J].
Clémenty, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11) :2192-2197
[5]   A sensor-based evaluation of heart contractility in patients with head-up tilt-induced syncope [J].
Deharo, JC ;
Peyre, JP ;
Ritter, PH ;
Chalvidan, T ;
Berland, Y ;
Djiane, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01) :223-226
[6]  
DUPUIS JM, 2000, EUROPACE SD, V1, pD23
[7]   ASSESSMENT OF THE OPTIMAL ATRIOVENTRICULAR DELAY IN DDD PACED PATIENTS BY IMPEDANCE PLETHYSMOGRAPHY [J].
EUGENE, M ;
LASCAULT, G ;
FRANK, R ;
FONTAINE, G ;
GROSGOGEAT, Y ;
TEILLAC, A .
EUROPEAN HEART JOURNAL, 1989, 10 (03) :250-255
[8]   IMPORTANCE OF AN INDIVIDUALLY PROGRAMMED ATRIOVENTRICULAR DELAY AT REST AND ON WORK CAPACITY IN PATIENTS WITH DUAL-CHAMBER PACEMAKERS [J].
FRIELINGSDORF, J ;
GERBER, AE ;
DUR, P ;
VUILLIOMENET, A ;
BERTEL, O .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01) :37-45
[9]   USEFULNESS OF PHYSIOLOGICAL DUAL-CHAMBER PACING IN DRUG-RESISTANT IDIOPATHIC DILATED CARDIOMYOPATHY [J].
HOCHLEITNER, M ;
HORTNAGL, H ;
NG, CK ;
HORTNAGL, H ;
GSCHNITZER, F ;
ZECHMANN, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (02) :198-202
[10]   EVALUATION BY PULSED DOPPLER ECHOCARDIOGRAPHY OF THE ATRIAL CONTRIBUTION TO LEFT-VENTRICULAR FILLING IN PATIENTS WITH DDD PACEMAKERS [J].
IWASE, M ;
SOTOBATA, I ;
YOKOTA, M ;
TAKAGI, S ;
JING, HX ;
KAWAI, N ;
HAYASHI, H ;
MURASE, M .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (01) :104-109